CoChat

Visual assessment of hemolysis affects patient safety

Luksic, Ana Helena, Nikolac Gabaj, Nora, Miler, Marijana, Dukic, Lora, Bakliza, Ana, Simundic, Ana-Maria · 2018 · Clinical Chemistry and Laboratory Medicine (CCLM)
Cited by 42

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Manual handling of hemolyzed samples is not standardized and is vulnerable to errors. This study aimed to evaluate laboratory errors due to manual handling of hemolyzed samples and to assess the risk they might have for patient safety. Methods: Data were retrospectively obtained from a laboratory information system for 25 emergency tests from hemolyzed samples. Hemolysis (concentration of free hemoglobin >0.5 g/L) was visually assessed by comparison with a color chart. The reference person reestimated the routinely assessed degree of hemolysis to all samples (n=3185) received in the laboratory in a 1-week period. For each test, the correct and incorrect way of handling results was determined. Risk assessment was performed according to ISO 14971 standard with five categories of risk (S1–S5) and error occurrence (O1–O5). Results: In the studied period, the emergency laboratory received 495 hemolyzed samples (15.5%) with a total of 2518 laboratory test requests (15.5%): 102 (20.6%) of the reports from hemolyzed samples had a comment on hemolysis; 31% of the test results were handled incorrectly (20.7% due to the incorrect release of the test result despite hemolysis interference and 10.3% due to unnecessary suppression), accounting for 4.8% of the total test volume. Tests with the highest combination of risk and occurrence rate were troponin T, potassium and total bilirubin. Conclusions: Manual handling of hemolyzed samples may lead to risk of errors in reporting results for troponin T, potassium and total bilirubin, which may have an effect on clinical decision. In addition, unnecessary suppression of the sample results unaffected by hemolysis could affect patient outcome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm-2017-0532

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 17

  1. Milutinovic D, Andrijevic I, Licina M, Andrijevic LJ. Confidence level in venipuncture and knowledge on causes of in vitro hemolysis among healthcare professionals. Biochem Med 2015;25:401–9. · DOI
  2. Carraro P, Plebani M. Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem 2007;53:1338–42. · DOI · Paper page
  3. Lippi G, Blanckaert N, Bonini P, Green S, Kitchen S, Palicka V, et al. Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories. Clin Chem Lab Med 2008;46:764–72. · DOI · Paper page
  4. Lippi G, Plebani M, Di Somma S, Cervellin G. Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories. Crit Rev Clin Lab Sci 2011;48:143–53. · DOI · Paper page
  5. Simundic AM, Nikolac N, Ivankovic V, Ferenec-Ruzic D, Magdic B, Kvaternik M, et al. Comparison of visual vs. automated detection of lipemic, icteric and hemolyzed specimens: can we rely on a human eye? Clin Chem Lab Med 2009;47:1361–5. · DOI · Paper page
  6. Jeffery J, Sharma A, Ayling RM. Detection of haemolysis and reporting of potassium results in samples from neonates. Ann Clin Biochem 2009;46:222–5. · doi:10.1258/acb.2009.008241
  7. Dolci A, Panteghini M. Harmonization of automated hemolysis index assessment and use: is it possible? Clin Chim Acta 2014;15:38–43. · DOI
  8. Lippi G, Banfi G, Church S, Cornes M, De Carli G, Grankvist K, et al. Preanalytical quality improvement. In pursuit of harmony, on behalf of European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working group for Preanalytical Phase (WG-PRE). Clin Chem Lab Med 2015;53:357–70. · DOI · Paper page
  9. Glick MR, Ryder KW, Glick SJ, Woods JR. Unreliable visual estimation of the incidence and amount of turbidity, hemolysis, and icterus in serum from hospitalized patients. Clin Chem 1989;35:837–9. · doi:10.1093/clinchem/35.5.837
  10. Hawkins RC. Discrepancy between visual and spectrophotometric assessment of sample hemolysis. Ann Clin Biochem 2002;39:521–2. · DOI
  11. Asirvatham JR, Moses V, Bjorson L. Errors in potassium measurement: a laboratory perspective for the clinician. N Am J Med Sci 2013;5:255–9. · DOI · Paper page
  12. Bilic-Zulle L, Simundic AM, Supak-Smolcic V, Nikolac N, Honovic L. Self reported routines and procedures for the extraanalytical phase of laboratory practice in Croatia – crosssectional survey study. Biochem Med 2010;20:64–74. · DOI · Paper page
  13. Lyon ME, Ball CL, Krause RD, Slotsve GA, Lyon AW. Effect of hemolysis on cardiac troponin T determination by the Elecsys 2010 immunoanalyzer. Clin Biochem 2004;37:698–701. · doi:10.1016/j.clinbiochem.2004.03.002
  14. Sodi R, Darn SM, Davison AS, Stott A, Shenkin A. Mechanism of interference by haemolysis in the cardiac troponin T immunoassay. Ann Clin Biochem 2006;43:49–56. · DOI
  15. Algeciras-Schimnich A, Cook WJ, Milz TC, Saenger AK, Karon BS. Evaluation of hemoglobin interference incapillary heel-stick samples collected for determination of neonatal bilirubin. Clin Biochem 2007;40:1311–6. · doi:10.1016/j.clinbiochem.2007.08.003
  16. Simundic AM, Topic E, Nikolac N, Lippi G. Hemolysis detection and management of hemolysed specimens. Biochem Med 2010;20:154–9. · DOI · Paper page
  17. Nikolac N, Celap I, Filipi P, Hemar M, Kocijancic M, Miler M, et al. Croatian laboratories have a good knowledge of the proper detection and management of hemolyzed, icteric and lipemic samples. Clin Chem Lab Med 2016;54:419–25. · DOI

Cited by

Metadata

Authors
Luksic, A. H., Nikolac Gabaj, N., Miler, M., Dukic, L., Bakliza, A., & Simundic, A.-M.
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2017-11-02
Volume
56
Issue
4
Pages
574-581
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2767167357
Cited by
42
References
1
FWCI
3.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.