A microneedle device for rapid dermal interstitial fluid sampling
Open accessPublished version of a preprint
Abstract
Dermal interstitial fluid (ISF) offers a promising alternative to invasive blood tests and opportunities for skin diagnostics. Progress in both the understanding and adoption of ISF tests is hindered by sampling challenges, including lengthy collection times, non-negligible failure rates, variable collection volumes, and inconsistent bioanalyte levels. The causes of many of these issues are not well understood. We demonstrate a microneedle device that is several times faster than state of the art, collecting an average of 15.5 mg of ISF in 5 minutes in humans with near-zero failure rate. This improvement was achieved by designing the spatial pressure gradient driving ISF flow. The influence of penetration depth, collection time, pressure, and age on ISF collection was elucidated, with Darcy’s law explaining multiple observations. A data-driven acceptance criterion of <1% blood contamination for ISF is proposed. The device and findings presented will empower researchers to better conduct robust studies in the development of ISF diagnostics.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Global quantification of mammalian gene expression control
Schwanhäusser, B., Busse, D., Li, N., Dittmar, G., Schuchhardt, J., Wolf, J., Chen, W., & Selbach, M. (2011) · Nature · doi:10.1038/nature10098 · Cited by 6,566 · see citing works
A Direct Approach to False Discovery Rates
Storey, J. D. (2002) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00346 · Cited by 5,603 · see citing works
Cox, J., Hein, M. Y., Luber, C. A., Paron, I., Nagaraj, N., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.031591 · Cited by 5,180 · see citing works
Continuous liquid interface production of 3D objects
Tumbleston, J. R., Shirvanyants, D. G., Ermoshkin, N., Janusziewicz, R., Johnson, A. R., Kelly, D., Chen, K., PINSCHMIDT, R. K. J., Rolland, J. P., Ermoshkin, A. V., et al. (2015) · Science · doi:10.1126/science.aaa2397 · Cited by 2,295 · see citing works
Self-citationThe PRIDE database at 20 years: 2025 update
Pérez‐Riverol, Y., Bandla, C., Kundu, D. J., Kamatchinathan, S., Bai, J., Hewapathirana, S., John, N. S., Prakash, A., Walzer, M., Wang, S., et al. (2024) · Nucleic Acids Research · doi:10.1093/nar/gkae1011 · Cited by 2,075 · see citing works
Sizing and phenotyping of cellular vesicles using Nanoparticle Tracking Analysis
Dragovic, R., Gardiner, C., Brooks, A. S., Tannetta, D., Ferguson, D. J. P., Hole, P., Carr, B., Redman, C. W. G., Harris, A. L., Dobson, P. J., et al. (2011) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2011.04.003 · Cited by 1,368 · see citing works
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758 · see citing works
Wiig, H., & Swartz, M. A. (2012) · Physiological Reviews · doi:10.1152/physrev.00037.2011 · Cited by 726 · see citing works
Extracellular vesicle sizing and enumeration by nanoparticle tracking analysis
Gardiner, C., Ferreira, Y. J., Dragovic, R., Redman, C. W. G., & Sargent, I. L. (2013) · Journal of Extracellular Vesicles · doi:10.3402/jev.v2i0.19671 · Cited by 586 · see citing works
FLOW THROUGH INTERSTITIUM AND OTHER FIBROUS MATRICES
Levick, J. R. (1987) · Quarterly Journal of Experimental Physiology · doi:10.1113/expphysiol.1987.sp003085 · Cited by 478 · see citing works
On the tear resistance of skin
Yang, W., Sherman, V. R., Gludovatz, B., Schaible, E. G., Stewart, P., Ritchie, R. O., & Meyers, M. A. (2015) · Nature Communications · doi:10.1038/ncomms7649 · Cited by 476 · see citing works
Biomechanical Properties of <i>In Vivo</i> Human Skin From Dynamic Optical Coherence Elastography
Liang, X., & Boppart, S. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033464 · Cited by 470 · see citing works
Sampling interstitial fluid from human skin using a microneedle patch
Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J. L., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw0285 · Cited by 387 · see citing works
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G. B., Polsky, R., Cunningham, D. D., Soh, H. T., & Heikenfeld, J. C. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 381 · see citing works
Mechanisms of sampling interstitial fluid from skin using a microneedle patch
Samant, P. P., & Prausnitz, M. R. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716772115 · Cited by 368 · see citing works
Structure and Distribution of an Unrecognized Interstitium in Human Tissues
Benias, P. C., Wells, R. G., Sackey-Aboagye, B., Klavan, H., Reidy, J., Buonocore, D. J., Miranda, M., Kornacki, S., Wayne, M. G., Carr-Locke, D. L., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-23062-6 · Cited by 355 · see citing works
Age-dependent biomechanical properties of the skin
Pawlaczyk, M., Lelonkiewicz, M., & Wieczorowski, M. (2013) · Advances in Dermatology and Allergology · doi:10.5114/pdia.2013.38359 · Cited by 337 · see citing works
Composition of interstitial fluid
Fogh-Andersen, N., Altura, B. M., Altura, B. T., & Siggaard-Andersen, O. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.10.1522 · Cited by 309 · see citing works
Li, C., Guan, G., Reif, R., Huang, Z., & Wang, R. K. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0583 · Cited by 302 · see citing works
Oltulu, P., İnce, B., Kökbudak, N., Fındık, S., & Kılınç, F. (2018) · Turkish Journal of Plastic Surgery · doi:10.4103/tjps.tjps_2_17 · Cited by 276 · see citing works
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Wang, P. M., Cornwell, M., & Prausnitz, M. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.131 · Cited by 267 · see citing works
Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles
Miller, P. R., Taylor, R. M., Tran, B. Q., Boyd, G., Glaros, T., Chavez, V. H., Krishnakumar, R., Sinha, A., Poorey, K., Williams, K. P., et al. (2018) · Communications Biology · doi:10.1038/s42003-018-0170-z · Cited by 263 · see citing works
Intravital analysis of vascular permeability in mice using two-photon microscopy
Egawa, G., Nakamizo, S., Natsuaki, Y., Doi, H., Miyachi, Y., & Kabashima, K. (2013) · Scientific Reports · doi:10.1038/srep01932 · Cited by 212 · see citing works
Tran, B. Q., Miller, P. R., Taylor, R. M., Boyd, G., Mach, P. M., Rosenzweig, C. N., Baca, J. T., Polsky, R., & Glaros, T. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00642 · Cited by 200 · see citing works
Interstitial Fluid Pressure: III. Its Effect on Resistance to Tissue Fluid Mobility
Guyton, A. C., Scheel, K. W., & MURPHREE, D. (1966) · Circulation Research · doi:10.1161/01.res.19.2.412 · Cited by 180 · see citing works
Viscoelastic response of human skin to low magnitude physiologically relevant shear
Holt, B., Tripathi, A., & Morgan, J. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.06.008 · Cited by 161 · see citing works
The Determination of Lipids and Proteins in Suction Blister Fluid
Vermeer, B. J., Reman, F. C., & van Gent, C. M. (1979) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12531833 · Cited by 137 · see citing works
Methodology to determine failure characteristics of planar soft tissues using a dynamic tensile test
Jacquemoud, C., Bruyère-Garnier, K., & Coret, M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.12.010 · Cited by 136 · see citing works
Interstitial fluid flow as a factor in decubitus ulcer formation
Reddy, N. P., Cochran, G. V. B., & Krouskop, T. A. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90015-4 · Cited by 123 · see citing works
Suction blister fluid as potential body fluid for biomarker proteins
Kool, J., Reubsaet, L., Wesseldijk, F., Maravilha, R. T., Pinkse, M. W. H., D’Santos, C. S., van Hilten, J. J., Zijlstra, F. J., & Heck, A. J. R. (2007) · PROTEOMICS · doi:10.1002/pmic.200600938 · Cited by 106 · see citing works
Single-digit-micrometer-resolution continuous liquid interface production
Hsiao, K., Lee, B. J., Samuelsen, T., Lipkowitz, G., Kronenfeld, J. M., Ilyn, D., Shih, A., Dulay, M. T., Tate, L., Shaqfeh, E. S. G., et al. (2022) · Science Advances · doi:10.1126/sciadv.abq2846 · Cited by 105 · see citing works
Self-citationHuman Suction Blister Fluid Composition Determined Using High-Resolution Metabolomics
Niedzwiecki, M. M., Samant, P. P., Walker, D. I., Tran, V., Jones, D. P., Prausnitz, M. R., & Miller, G. W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04073 · Cited by 102 · see citing works
Microdialysis methodology for the measurement of dermal interstitial fluid in humans
Krogstad, A., Jansson, P., GISSLÉN, P., & Lönnroth, P. (1996) · British Journal of Dermatology · doi:10.1046/j.1365-2133.1996.d01-893.x · Cited by 98 · see citing works
Lynch, B., Pageon, H., Blay, H. L., Brizion, S., Bastien, P., Bornschlögl, T., & Domanov, Y. A. (2022) · Scientific Reports · doi:10.1038/s41598-022-04767-1 · Cited by 92 · see citing works
Golombek, S., Pilz, M., Steinle, H., Kochba, E., Levin, Y., Lunter, D., Schlensak, C., Wendel, H. P., & Avci-Adali, M. (2018) · Molecular Therapy Nucleic Acids · doi:10.1016/j.omtn.2018.03.005 · Cited by 88 · see citing works
Ribet, F., Bendes, A., Fredolini, C., Dobielewski, M., Böttcher, M., Beck, O., Schwenk, J. M., Stemme, G., & Roxhed, N. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202202564 · Cited by 56 · see citing works
Lipid profiling of suction blister fluid: comparison of lipids in interstitial fluid and plasma
Nilsson, A., Sjöbom, U., Christenson, K., & Hellström, A. (2019) · Lipids in Health and Disease · doi:10.1186/s12944-019-1107-3 · Cited by 52 · see citing works
Dwivedi, K. K., Lakhani, P., Kumar, S., & Kumar, N. (2022) · Royal Society Open Science · doi:10.1098/rsos.211301 · Cited by 44 · see citing works
Visual assessment of hemolysis affects patient safety
Lukšić, A. H., Nikolac, N., Miler, M., Dukić, L., Bakliža, A., & Šimundić, A.-M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0532 · Cited by 41 · see citing works
Michel, C. C., Nanjee, M. N., Olszewski, W. L., & Miller, N. E. (2014) · Journal of Lipid Research · doi:10.1194/jlr.m055053 · Cited by 36 · see citing works
Microneedle-based sampling of dermal interstitial fluid using a vacuum-assisted skin patch
Jiang, X., Wilkirson, E. C., Bailey, A. O., Russell, W. K., & Lillehoj, P. B. (2024) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2024.101975 · Cited by 33 · see citing works
Concentration of plasma albumin in its accessible space in postmortem human dermis
Bert, J. L., Pearce, R. H., & Mathieson, J. M. (1986) · Microvascular Research · doi:10.1016/0026-2862(86)90055-5 · Cited by 32 · see citing works
Protein Concentration of Subcutaneous Interstitial Fluid in the Human Leg
Haaverstad, R., Romslo, I., Larsen, S., & Myhre, H. O. (2008) · International Journal of Microcirculation · doi:10.1159/000179159 · Cited by 32 · see citing works
3D‐Printed Latticed Microneedle Array Patches for Tunable and Versatile Intradermal Delivery
Rajesh, N. U., Hwang, J., Xu, Y., Saccone, M. A., Hung, A. H., Hernandez, R. A. S., Coates, I. A., Driskill, M. M., Dulay, M. T., Jacobson, G. B., et al. (2024) · Advanced Materials · doi:10.1002/adma.202404606 · Cited by 30 · see citing works
Self-citationProteomic Characterization of Immunoglobulin Content in Dermal Interstitial Fluid
Arévalo, M. T., Rizzo, G. M., Polsky, R., Glaros, T., & Mach, P. M. (2019) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00155 · Cited by 29 · see citing works
Zhang, X., Zhang, W., Wu, W., & Chen, J. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.109477 · Cited by 26 · see citing works
Plasma proteins in a standardised skin mini-erosion (II): effects of extraction pressure
Svedman, C., Yu, B. B., Ryan, T. J., & Svensson, H. (2002) · BMC Dermatology · doi:10.1186/1471-5945-2-4 · Cited by 13 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Zhao, J., Xu, H., Fei, S., Xu, C., Yin, W., Wei, Q., Lin, J., Liu, G., Feng, S., Gao, F., et al. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.118943 · Cited by 15 · see citing works
Yuan, R., Ma, X., Zou, G., Zhou, G., Liu, J., Li, W., Xu, Y., Su, S., & Wang, L. (2026) · The Analyst · doi:10.1039/d5an01250c · Cited by 14 · see citing works
Challenges of Wearable Biosensors and Ways to Overcome Them
Tarasov, S. E., Plekhanova, Y. V., Reshetilov, A., Melenkov, S., & Saltanov, I. (2026) · Biosensors · doi:10.3390/bios16030159 · Cited by 10 · see citing works
Somandi, K., Kulati, H., Holman, D. E., Abrahams, A.-I., Ngoepe, M. P., Keyster, M., & Choonara, Y. E. (2026) · Drug Delivery and Translational Research · doi:10.1007/s13346-026-02106-9 · Cited by 6 · see citing works
Microneedles biosensors for disease diagnosis: From fabrication to AI enhancement
Wu, M., & Liu, L. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118731 · Cited by 5 · see citing works
Rath, R. J., Brasier, N., Quesada-González, D., Talebian, S., Langley, D., Sanli, A., Sempionatto, J. R., Greene, G. W., Beuschlein, F., Merkoçi, A., et al. (2026) · Device · doi:10.1016/j.device.2026.101214 · Cited by 4 · see citing works
Microneedle-integrated wearable devices for healthcare monitoring
Tianli, H. U., Ko, E. B., Song, Y., & Xu, C. (2026) · Lab on a Chip · doi:10.1039/d5lc00993f · Cited by 3 · see citing works
Chen, Q., Chen, H., Li, Y., Yang, P., Li, R., & Zhou, Z. (2026) · FlexMat. · doi:10.1002/flm2.70099 · Cited by 2 · see citing works
Tunable Applicator for Microneedle‐Based Medical Devices
Ilyn, D., Hwang, J., Coates, I. A., Dobson, J., Hung, A. H., Kamat, N. U., Tumbleston, J. R., Dulay, M. T., Jacobson, G. B., & DeSimone, J. M. (2026) · Advanced Materials Technologies · doi:10.1002/admt.202502525 · Cited by 1 · see citing works
Self-citationMalhotra, S., & Kumar, A. (2026) · Frontiers in Sensors · doi:10.3389/fsens.2026.1819441 · Cited by 1 · see citing works
Cai, H., He, Y. F., Wang, C., Zhao, Y., & Yang, C. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1885022 · Cited by 1 · see citing works
Fu, J., Chen, Z., Wen, X., Li, S., Wang, Y., Li, Z., Zhu, Y. C., Xu, C., & Chang, H. (2026) · Materials Today Bio · doi:10.1016/j.mtbio.2026.103480 · Cited by 1 · see citing works
Vacuum-Assisted Microneedle Platforms for Dermal Interstitial Fluid Sampling
Hwang, J. C., Dulay, M. T., Schaar, B. T., & DeSimone, J. M. (2026) · Pharmaceutics · doi:10.3390/pharmaceutics18080926
Self-citationRehman, K., & Akash, M. S. H. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-45911-5.00018-0
Zhou, Y., Li, S., He, L., Qi, L., Yin, G., Zhou, H., Long, W., Chen, Y., Wang, K., & He, X. (2026) · Talanta · doi:10.1016/j.talanta.2026.130836
Advances in functional hydrogel materials for biosensing
Yavari, N., Simms, B. L., & Strobbia, P. (2026) · Analytical Methods · doi:10.1039/d6ay01232a
Research progress in microneedle-based electrochemical sensing for health monitoring
Zhao, Y., Cheng, X., Fan, Z., Mu, L., Li, H., Song, S., Li, Z., Jeerapan, I., & Zhu, Z. (2026) · Biomedical Instrumentation · doi:10.1016/j.bmi.2026.100070
Iacono, S. D., Battisti, M., Amendola, E., Cammarano, A., Corrado, B., Stefano, L. D., Mangini, M., Luca, A. C. D., Fabbrocino, F., Moscatelli, F., et al. (2026) · Materials Advances · doi:10.1039/d6ma00677a
Microneedle biosensors: from molecular recognition to intelligent diagnostics
He, L., Yan, Z., Zheng, W., Qi, L., Liu, J., & He, X. (2026) · Chemical Communications · doi:10.1039/d6cc04191d
Shiu, M. Y. Y., Cote, M., McLeish, N. J., Bae, J. H., & Rhind, S. G. (2026) · Brain Sciences · doi:10.3390/brainsci16101057
Cortisol Dynamics at High Temporal Resolution For Wearable Biosensor Research
Ferdoushi, M., Billings, T., Cai, W.-X., & Khan, Y. (2026) · Advanced Sensor Research · doi:10.1002/adsr.70212
Ji, J., Mao, T., Tong, L., Wang, Y., Zhang, T., Chen, Z., & Zhang, D. (2026) · Materials Today Advances · doi:10.1016/j.mtadv.2026.101032
- Authors
- Hung, A. H., Kamat, N. U., Bermudez, A., Boczek, S. M., Garcia-Marqués, F. J., Tan, Y. L., Hwang, J. (., Sinawang, P. D., Ilyin, D., Jacobson, G. B., Demirci, U., Poplack, S. P., Pitteri, S. J., & DeSimone, J. M.
- Affiliations
- Stanford Medicine (US)
- Department of Bioengineering, Stanford University, CA 94305, USA.
- Stanford University (US)
- Department of Radiology, School of Medicine, Stanford University, CA 94305, USA.
- Corresponding author
- DeSimone, Joseph M.
- ORCID
- Venue
- Science Advances
- Published
- 2025-09-26
- Volume
- 11
- Issue
- 39
- Pages
- eadx5492-eadx5492
- ISSN
- 2375-2548 (ISSN-L)
- PMC
- PMC12459406
- OpenAlex
- W4414533144
- Cited by
- 22
- References
- 47
- Citations by year
- 2026: 22
- FWCI
- 9.31
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Science Advances (publishedVersion, cc-by)
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion, cc-by)
- Funders
- National Cancer Institute (T32CA009695)
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- dermal interstitial fluid, dermatological diagnosis, Darcy's law, penetration depth, blood contamination, collection time, non-invasive sampling
- MeSH terms
- Humans, Needles, Skin, Specimen Handling, Extracellular Fluid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review