The DOI matches its Crossref record.
Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots
Open accessAbstract
INTRODUCTION: The aim of this paper is to present results of first two years of preanalytical external quality assessment (EQA) in Croatia. MATERIALS AND METHODS: This paper summarizes results from 6 rounds of preanalytical EQA during 2014-2016 in 161-175 Croatian laboratories (number ranged between cycles). EQA was designed as an online survey of the compliance with National recommendations for phlebotomy (NRP). Forty-seven questions in 5 categories are analyzed (materials and equipment, patient identification, patient preparation, sampling and storage). Additionally, preanalytical cases are presented. Overall performance scores (Question score (Qscore) for compliance with NRP and Case score (Cscore) for preanalytical cases) are calculated for each question/case as a proportion of laboratories with satisfactory procedure (x 100). Qscores and Cscores ≥ 70 were classified as acceptable (maximal score = 100). RESULTS: In investigation of compliance with NRP, acceptable Qscores were obtained for 34/47 questions. The lowest scores were observed for the availability of sterile disposable tourniquets (Qscore = 15) and safe-sharp needles (Qscore = 34), obtaining patients address as an identifier (Qscore = 21), using glycolysis inhibitor tubes for glucose concentration measurement (Qscore = 21) and verification of manufacturers declarations on temperature and time of storage (Qscore = 31). There was no statistically significant difference in overall Qscore according to different categories of phlebotomy procedures (P = 0.284). The results of preanalytical cases showed acceptable Cscore values for all cases (89-96). CONCLUSION: First two years of preanalytical EQA showed good compliance with the NRP and excellent expertise in resolving complex preanalytical issues. Major critical spots are lack of availability of safe-sharp needles, disposable tourniquets and glucose inhibitor tubes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Unfortunately, disposable tourniquets are not widely used, especially in some developing or non-developed countries [53].”
From Joint EFLM-COLABIOCLI Recommendation for venous blood sampling (2018) · cites this paper as [53]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 26
- [2]Kristensen GB, Aakre KM, Kristoffersen AH, Sandberg S. How to conduct External Quality Assessment Schemes for the pre-analytical phase? Biochem Med (Zagreb) 2014;24:114-22. https://doi.org/10.11613/BM.2014.013. PMC3936964 24627720 · DOI
- [3]Alsina MJ Alvarez V, Barba N, Bullich S, Cortés M, Escoda I, Martínez-Brú C. Preanalytical quality control program - an overview of results (2001-2005 summary). Clin Chem Lab Med. 2008; 46: 849– 54. 18601609
- [4]Llopis MA, Bauça JM, Barba N, Álvarez V, Ventura M, Ibarz M, et al. Spanish Preanalytical Quality Monitoring Program (SEQC), an overview of 12 years’ experience. Clin Chem Lab Med 2016. [Epub ahead of print]. 10.1515/cclm-2016-0382. 27658151 · DOI
- [5]Bilic-Zulle L, Simundic AM, Supak Smolcic V, Nikolac N, Honovic L. Self reported routines and procedures for the extra-analytical phase of laboratory practice in Croatia - cross-sectional survey study. Biochem Med (Zagreb) 2010;20:64-74. https://doi.org/10.11613/BM.2010.008. · DOI
- [6]Simundic AM Bilic-Zulle L Nikolac N Supak-Smolcic V Honovic L Avram S The quality of the extra-analytical phase of laboratory practice in some less developed European countries and Mexico – multicentric study. Clin Chem Lab Med. 2011; 49: 215– 28. 10.1515/CCLM.2011.034 10.1515/CCLM.2011.034 21118049 · DOI
- [7]Nikolac N, Šupak-Smolčić V, Šimundić AM, Ćelap I. Croatian Society of Medical Biochemistry and Laboratory Medicine: national recommendations for venous blood sampling. Biochem Med (Zagreb) 2013;23:242-54. https://doi.org/10.11613/BM.2013.031. PMC3900082 24266294 · DOI · Paper page
- [9]Rourke C Bates C Read RC Poor hospital infection control practice in venepuncture and use of tourniquets. J Hosp Infect. 2001; 49: 59– 61. 10.1053/jhin.2001.1038 10.1053/jhin.2001.1038 11516188 · DOI
- [10]Leitch A McCormick I Gunn I Gillespie T Reducing the potential for phlebotomy tourniquets to act as a reservoir for meticillin-resistant Staphylococcus aureus. J Hosp Infect. 2006; 63: 428– 31. 10.1016/j.jhin.2006.03.006 10.1016/j.jhin.2006.03.006 16759742 · DOI
- [11]Elhassan HA Dixon T MRSA contaminated venepuncture tourniquets in clinical practice. Postgrad Med J. 2012; 88: 194– 7. 10.1136/postgradmedj-2011-130411 10.1136/postgradmedj-2011-130411 22298685 · DOI
- [13]Tarigan LH Cifuentes M Quinn M Kriebel D Prevention of needle-stick injuries in healthcare facilities: a meta-analysis. Infect Control Hosp Epidemiol. 2015; 36: 823– 9. 10.1017/ice.2015.50 10.1017/ice.2015.50 25765502 · DOI
- [14]De Carli G, Abiteboul D, Puro V. The importance of implementing safe sharps practices in the laboratory setting in Europe. Biochem Med (Zagreb) 2014;24:45-56. https://doi.org/10.11613/BM.2014.007. PMC3936965 24627714 · DOI · Paper page
- [15]Hanmore E Maclaine G Garin F Alonso A Leroy N Ruff L Economic benefits of safety-engineered sharp devices in Belgium - a budget impact model. BMC Health Serv Res. 2013; 13: 489. 10.1186/1472-6963-13-489 10.1186/1472-6963-13-489 24274747 PMC4222860 · DOI
- [16]Simundic AM Church S Cornes MP Grankvist K Lippi G Nybo M Compliance of blood sampling procedures with CLSI H3-A6 standard for the collection of diagnostic blood specimens by venipuncture and risk assessment analysis: An observational study by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PRE). Clin Chem Lab Med. 2015; 53: 1321– 31. 10.1515/cclm-2014-1053 10.1515/cclm-2014-1053 25536667 · DOI
- [17]van Dongen-Lases EC Cornes MP Grankvist K Ibarz M Kristensen GB Lippi G Working Group for Preanalytical Phase (WG-PRE), European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Patient identification and tube labelling - a call for harmonisation. Clin Chem Lab Med. 2016; 54: 1141– 5. 10.1515/cclm-2015-1089 10.1515/cclm-2015-1089 26816400 · DOI · Paper page
- [18]Nikolac N Simundic AM Kackov S Serdar T Dorotic A Fumic K The quality and scope of information provided by medical laboratories to patients before laboratory testing: Survey of the Working Group for Patient Preparation of the Croatian Society of Medical Biochemistry and Laboratory Medicine. Clin Chim Acta. 2015; 450: 104– 9. 10.1016/j.cca.2015.08.001 10.1016/j.cca.2015.08.001 26253925 · DOI
- [20]Simundic AM Cornes M Grankvist K Lippi G Nybo M Standardization of collection requirements for fasting samples: for the Working Group on Preanalytical Phase (WG-PA) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM). Clin Chim Acta. 2014; 432: 33– 7. 10.1016/j.cca.2013.11.008 10.1016/j.cca.2013.11.008 24269503 · DOI · Paper page
- [21]Guidi GC Simundic AM Salvagno GL Aquino JL Lima-Oliveira G To avoid fasting time, more risk than benefits. Clin Chem Lab Med. 2015; 53: e261– 4. 10.1515/cclm-2014-1013 10.1515/cclm-2014-1013 25389995 · DOI
- [22]Lippi G, Bonelli P, Bonfanti L, Cervellin G. The use of S-Monovette is effective to reduce the burden of hemolysis in a large urban emergency department. Biochem Med (Zagreb) 2015;25:69-72. https://doi.org/10.11613/BM.2015.008. PMC4401311 25672469 · DOI
- [23]Lippi G Ippolito L Zobbi V Sandei F Favaloro EJ Sample collection and platelet function testing: influence of vacuum or aspiration principle on PFA-100 test results. Blood Coagul Fibrinolysis. 2013; 24: 666– 9. 10.1097/MBC.0b013e32835fada7 10.1097/MBC.0b013e32835fada7 23470650 · DOI
- [24]Lippi G Banfi G Church S Cornes M De Carli G Grankvist K Preanalytical quality improvement. In pursuit of harmony, on behalf of European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working group for Preanalytical Phase (WG-PRE). Clin Chem Lab Med. 2015; 53: 357– 70. 10.1515/cclm-2014-1051 10.1515/cclm-2014-1051 25490032 · DOI
- [25]Juricic G Kopcinovic LM Saracevic A Bakliza A Simundic AM Liquid citrate acidification introduces significant glucose bias and leads to misclassification of patients with diabetes. Clin Chem Lab Med. 2016; 54: 363– 71. 10.1515/cclm-2015-0358 10.1515/cclm-2015-0358 26136303 · DOI
- [26]Juricic G Bakliza A Saracevic A Kopcinovic LM Dobrijevic S Drmic S Glucose is stable during prolonged storage in un-centrifuged Greiner tubes with liquid citrate buffer, but not in serum and NaF/KOx tubes. Clin Chem Lab Med. 2016; 54: 411– 8. 10.1515/cclm-2015-0746 10.1515/cclm-2015-0746 26695197 · DOI
- [28]Saracevic A Nikolac N Simundic AM The evaluation and comparison of consecutive high speed centrifugation and LipoClear® reagent for lipemia removal. Clin Biochem. 2014; 47: 309– 14. 10.1016/j.clinbiochem.2014.01.001 10.1016/j.clinbiochem.2014.01.001 24434304 · DOI
- [29]Nikolac N Simundic AM Miksa M Lima-Oliveira G Salvagno GL Caruso B Heterogeneity of manufacturers’ declarations for lipemia interference – urgent call for standardization. Clin Chim Acta. 2013; 426: 33– 40. 10.1016/j.cca.2013.08.015 10.1016/j.cca.2013.08.015 23981842 · DOI
- [30]Culjak M Nikolac N Simundic AM Short term storage stability of serum angiotensin-converting enzyme (ACE) activity. Clin Chim Acta. 2015; 446: 261– 2. 10.1016/j.cca.2015.05.001 10.1016/j.cca.2015.05.001 25957986 · DOI
- [31]Nikolac N Celap I Filipi P Hemar M Kocijancic M Miler M Croatian laboratories have a good knowledge of the proper detection and management of hemolyzed, icteric and lipemic samples. Clin Chem Lab Med. 2016; 54: 419– 25. 10.1515/cclm-2015-0650 10.1515/cclm-2015-0650 26426892 · DOI
Cited by
Sorted by citations
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Self-citationBacterial contamination of reusable venipuncture tourniquets in tertiary-care hospital
Culjak, M., Gveric Grginic, A., & Simundic, A.-M. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0994 · Cited by 11
Self-citation
Metadata
- Authors
- Nikolac, N., Lenicek Krleza, J., & Simundic, A.-M.
- Affiliations
- Sisters of Charity Hospital (HR)
- ORCID
- Nikolac, Nora
- Venue
- Biochemia Medica
- Published
- 2017
- Volume
- 27
- Issue
- 1
- Pages
- 131-143
- ISSN
- 1330-0962 (ISSN-L)
- 1846-7482
- PMC
- PMC5382847
- OpenAlex
- W2586198021
- Cited by
- 18
- References
- 0
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2019: 5 · 2018: 4 · 2017: 4
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- cc-by
- Locations
- Biochemia Medica (publishedVersion, cc-by)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- University of Zagreb University Computing Centre (SRCE) (submittedVersion, other-oa)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Quality and Management
- Health Sciences › Health Professions › Medical Laboratory Technology › Quality and Safety in Healthcare
- Keywords
- external quality assessment, phlebotomy, laboratory compliance, patient identification, patient preparation, sample storage, glucose measurement
- MeSH terms
- Biochemistry, Blood Specimen Collection, Humans, Quality Assurance, Health Care, Quality Control, Surveys and Questionnaires, Specimen Handling, Medical Laboratory Science, Croatia, Phlebotomy, Clinical Laboratory Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots. https://app.cochat.ai/papers/10.11613/bm.2017.017
- The paper
- Nikolac, N., Lenicek Krleza, J., & Simundic, A.-M. (2017). Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots. Biochemia Medica. https://doi.org/10.11613/bm.2017.017