CoChat

Bacterial contamination of reusable venipuncture tourniquets in tertiary-care hospital

Culjak, Marija, Gveric Grginic, Ana, Simundic, Ana-Maria · 2018 · Clinical Chemistry and Laboratory Medicine (CCLM)

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Article Bacterial contamination of reusable venipuncture tourniquets in tertiary-care hospital was published on August 1, 2018 in the journal Clinical Chemistry and Laboratory Medicine (CCLM) (volume 56, issue 8).

Overview

Integrity signals

Registry

Crossref · 10.1515/cclm-2017-0994

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 10 references

Research works printed but not linked: 10

  1. 2011, Reusable venesection tourniquets: a potential source of hospital transmission of multiresistant organisms, Med J Aust, 195, 276, 10.5694/mja11.10333 · DOI · Paper page
  2. 2016, Phlebotomy, a bridge between laboratory and patient, Biochem Med, 26, 17
  3. 2015, How compliant are technicians with universal safety measures in medical laboratories in Croatia? A pilot study, Biochem Med, 25, 386
  4. 2014, The importance of implementing safe sharps practices in the laboratory setting in Europe, Biochem Med, 24, 45
  5. 2014, Society for Healthcare Epidemiology of America (SHEA). A compendium of strategies to prevent healthcare-associated infections in acute care hospitals: 2014 updates, Infect Control Hosp Epidemiol, 35, 967, 10.1086/677216 · DOI
  6. 2014, Potential risk of cross-infection by tourniquets: a need for effective control practices in Pakistan, Int J Prev Med, 5, 1119
  7. 2017, Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots, Biochem Med, 27, 131
  8. 2009, Novel fit for purpose single use tourniquet: best of both worlds, J Med Eng Technol, 33, 475, 10.1080/03091900902952667 · DOI
  9. 2012, MRSA contaminated venepuncture tourniquets in clinical practice, Postgrad Med J, 88, 194, 10.1136/postgradmedj-2011-130411 · DOI
  10. 2010, Acinetobacter baumannii and MRSA contamination on reusable phlebotomy tourniquets, Clin Lab Sci, 23, 151, 10.29074/ascls.23.3.151 · DOI

Cited by

See all 11

Metadata

Authors
Culjak, M., Gveric Grginic, A., & Simundic, A.-M.
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2018-07-26
Volume
56
Issue
8
Pages
e201-e203
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2791177145
Cited by
11
References
10
Citations by year
2025: 2 · 2024: 2 · 2023: 1 · 2021: 2 · 2020: 1 · 2019: 2 · 2018: 1
FWCI
1.13
Type
journal article
Language
en
Open access
closed
Locations
  • Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
  • Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
Keywords
bacterial contamination, reusable medical devices, nosocomial infections, tertiary care hospital
MeSH terms
Bacteria, Humans, Tourniquets, Phlebotomy, Tertiary Care Centers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bacterial contamination of reusable venipuncture tourniquets in tertiary-care hospital. https://app.cochat.ai/papers/10.1515/cclm-2017-0994
The paper
Culjak, M., Gveric Grginic, A., & Simundic, A.-M. (2018). Bacterial contamination of reusable venipuncture tourniquets in tertiary-care hospital. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2017-0994

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.