CoChat

Critical appraisal and meta-analysis of biological variation estimates for kidney related analytes

Open access
Jonker, Niels, Aslan, Berna, Boned, Beatriz, Marqués-García, Fernando, Ricós, Carmen, Alvarez, Virtudes, Bartlett, William, Braga, Federica, Carobene, Anna, Coskun, Abdurrahman, Diaz-Garzón, Jorge, Fernández-Calle, Pilar, Gonzalez-Lao, Elisabet, Minchinela, Joana, Perich, Carmen, Simón, Margarita, Sandberg, Sverre, Aarsand, Aasne K. · 2022 · Clinical Chemistry and Laboratory Medicine (CCLM)

The DOI matches its Crossref record, with a small difference in title or year; 22 of the 24 references it cites were found in a registry or an index.

Abstract

Abstract Objectives Kidney markers are some of the most frequently used laboratory tests in patient care, and correct clinical decision making depends upon knowledge and correct application of biological variation (BV) data. The aim of this study was to review available BV data and to provide updated BV estimates for the following kidney markers in serum and plasma; albumin, creatinine, cystatin C, chloride, potassium, sodium and urea. Content Relevant studies were identified from a historical BV database as well as by systematic literature searches. Retrieved publications were appraised by the Biological Variation Data Critical Appraisal Checklist (BIVAC). Meta-analyses of BIVAC compliant studies with similar design were performed to deliver global estimates of within-subject (CV I ) and between-subject (CV G ) BV estimates. Out of the 61 identified papers, three received a BIVAC grade A, four grade B, 48 grade C, five grade D grade and one was not appraised as it did not report numerical BV estimates. Most studies were identified for creatinine (n=48). BV estimates derived from the meta-analysis were in general lower than previously reported estimates for all analytes except urea. For some measurands, BV estimates may be influenced by age or states of health, but further data are required. Summary This review provides updated global BV estimates for kidney related measurands. For all measurands except for urea, these estimates were lower than previously reported. Outlook For the measurands analyzed in this review, there are sufficient well-designed studies available to publish a trustworthy estimate of BV. However, for a number of newly appearing kidney markers no suitable data is available and additional studies are required.

Overview

CoChat Summary

TL;DR

This review/meta-analysis updated biological variation (BV) estimates for seven kidney-related markers in serum and plasma: albumin, creatinine, cystatin C, chloride, potassium, sodium, and urea. Using BIVAC appraisal and meta-analysis, the authors found the updated BV estimates were generally lower than previously reported for all analytes except urea.

Key findings

  • The authors identified 61 papers in total; 3 were graded A, 4 graded B, 48 graded C, 5 graded D, and 1 was not appraised because it did not report numerical BV estimates.
  • The largest evidence base was for creatinine (n = 48 studies).
  • Meta-analysis-derived BV estimates were generally lower than previously reported estimates for all analytes except urea.
  • The paper notes that for some measurands, BV may be influenced by age or states of health, but says further data are required.

Methods

  • The study was a critical appraisal and meta-analysis of biological variation estimates for kidney-related analytes in serum and plasma.
  • Relevant studies were identified from a historical BV database and systematic literature searches.
  • Retrieved publications were appraised using the Biological Variation Data Critical Appraisal Checklist (BIVAC), and meta-analyses of BIVAC-compliant studies with similar design were used to derive global estimates of within-subject (CVI) and between-subject (CVG) BV.

Limitations

  • The paper states that for some measurands, possible effects of age or health status on BV need more data.
  • It also states that for newly appearing kidney markers, no suitable data is available and additional studies are required.
  • Evident from the text: most included studies were graded C or D by BIVAC (48/61 C and 5/61 D), which suggests limited methodological quality in much of the available evidence.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1515/cclm-2020-1168

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 0 Not valid · 0 Not checked · 7 Own results and interpretations

  • Probably not a substantial claim. 4
  • It may state two separate claims as one. 1

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 22 references

Research works printed but not linked: 3

  1. Fraser, CG, Sandberg, S. Biological variation. In: Rifai, N, Horvath, AR, Wittwer, CT, editors. Tietz textbook of cinical chemistry and molecular biology, 6th ed. St. Louis, Missouri: Elsevier; 2017:157–70 pp.
  2. Ricós, C, Baadenhuijsen, H, Libeer, JC, Hyltoft Petersen, P, Stöckl, D, Thienpont, L, et al. Currently used criteria for evaluating performance in EQA in European countries and a proposal for harmonization. Eur J Clin Chem Clin Biochem 1996;34:159–65.
  3. Carobene, A, Marino, I, Coskun, A, Serteser, M, Unsal, I, Guerra, E, et al. The EuBIVAS project: within-and between-subject biological variation data for serum creatinine using enzymatic and alkaline picrate methods and implications for monitoring. Clin Chem 2017;63:1527–36. https://doi.org/10.1373/clinchem.2017.275115. · DOI · Paper page

Cited by

See all 26

Metadata

Authors
Jonker, N., Aslan, B., Boned, B., Marqués-García, F., Ricós, C., Alvarez, V., Bartlett, W., Braga, F., Carobene, A., Coskun, A., Diaz-Garzón, J., Fernández-Calle, P., Gonzalez-Lao, E., Minchinela, J., Perich, C., Simón, M., Sandberg, S., & Aarsand, A. K.
Affiliations
  • Certe-Wilhelmina Ziekenhuis Assen , Assen , The Netherlands
  • Institute for Quality Management in Healthcare (IQMH), Centre for Proficiency Testing , Toronto , Ontario , Canada
  • Hospital Royo Villanova (ES)
  • Spanish Society of Laboratory Medicine (SEQC ) , Analytical Quality Commission , Barcelona , Spain
  • University of Dundee (GB)
  • University of Milan (IT)
  • IRCCS Ospedale San Raffaele (IT)
  • Acibadem Mehmet Ali Aydınlar University, School of Medicine , Atasehir , Istanbul , Turkey
  • Hospital Universitari Germans Trias i Pujol (ES)
  • Haukeland University Hospital (NO)
Corresponding author
Jonker, Niels
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2020-10-19
Volume
60
Issue
4
Pages
469-478
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W3088409781
Cited by
26
References
24
Citations by year
2026: 2 · 2025: 3 · 2024: 5 · 2023: 5 · 2022: 5 · 2021: 6
FWCI
0.51
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
  • PubMed (publishedVersion)
  • NORA - Norwegian Open Research Archives (submittedVersion, other-oa)
  • Acibadem University Open Access Repository (submittedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
Keywords
biological variation, renal function markers, creatinine, cystatin C, serum albumin, urea, electrolytes, sodium, potassium, chloride, within-subject coefficient of variation
MeSH terms
Creatinine, Humans, Kidney, Urea, Biomarkers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-09, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-09 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Critical appraisal and meta-analysis of biological variation estimates for kidney related analytes. https://app.cochat.ai/papers/10.1515/cclm-2020-1168
The paper
Jonker, N., Aslan, B., Boned, B., Marqués-García, F., Ricós, C., Alvarez, V., Bartlett, W., Braga, F., Carobene, A., Coskun, A., Diaz-Garzón, J., Fernández-Calle, P., Gonzalez-Lao, E., Minchinela, J., Perich, C., Simón, M., Sandberg, S., & Aarsand, A. K. (2022). Critical appraisal and meta-analysis of biological variation estimates for kidney related analytes. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2020-1168

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.