Radioimmunoassay for Plasma Testosterone
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A sensitive radioimmunoassay for plasma testosterone has been developed. The antisera used were obtained by immunizing rabbits with testosterone-3-albumin or testosterone-3-hemocyanin conjugates. Applying a new immunization technique antibodies were obtained in high titer as early as four weeks after immunization. The standard curve of the assay extends over a wide range of dosages (0.025 to 10.0 ng). Reliability criteria are satisfactory. The assay compares favourably with competitive protein binding methods for testosterone. Ein empfindlicher Radioimmunoassay für Plasma-Testosteron wurde entwickelt. Die verwandten Antiseren wurden durch Immuni-sierung von Kaninchen mit Testosteron-3-Albuminr oder Testosteron-3-Hemocyanin-Konjugaten gewonnen. Unter Anwendung eines
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE ATTRACTIONS OF PROTEINS FOR SMALL MOLECULES AND IONS
Scatchard, G. (1949) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1949.tb27297.x · Cited by 19,778
Cited by
Hormones, Emotional Dispositions, and Aggressive Attributes in Young Adolescents
Susman, E. J., Inoff‐Germain, G., Nottelmann, E. D., Loriaux, D. L., Cutler, G. B., & Chrousos, G. P. (1987) · Child Development · doi:10.1111/j.1467-8624.1987.tb01445.x · Cited by 328
Self-citationHuman puberty. Simultaneous augmented secretion of luteinizing hormone and testosterone during sleep
Boyar, R. M., Rosenfeld, R. S., Kapen, S., Finkelstein, J. W., Roffwarg, H. P., Weitzman, E. D., & Hellman, L. (1974) · Journal of Clinical Investigation · doi:10.1172/jci107798 · Cited by 317
“The anti-T (rabbit) antibody was prepared by immunizing with 3-carboxymethoximino-T hemocyanin (30).”
MethodReproductive Functions in Young Fathers and Grandfathers
NIESCHLAG, E., LAMMERS, U., FREISCHEM, C. W., LANGER, K., & WICKINGS, E. J. (1982) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-55-4-676 · Cited by 312
Self-citationHypogonadism in Alcoholic Liver Disease: Evidence for a Double Defect
Van Thiel, D. H., Lester, R., & Sherins, R. J. (1974) · Gastroenterology · doi:10.1016/s0016-5085(19)32705-2 · Cited by 303
Hypothalamic-Pituitary Function in Diverse Hyperprolactinemic States
Boyar, R. M., Kapen, S., Finkelstein, J. W., Perlow, M., Sassin, J. F., Fukushima, D. K., Weitzman, E. D., & Hellman, L. (1974) · Journal of Clinical Investigation · doi:10.1172/jci107709 · Cited by 162
Metadata
- Authors
- NIESCHLAG, E., & LORIAUX, D. L.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 1972
- Volume
- 10
- Issue
- 4
- Pages
- 164-8
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W1986966445
- Cited by
- 212
- References
- 1
- FWCI
- 6.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.