Determination of Serum Cortisol by Isotope-Dilution Liquid-Chromatography Electrospray Ionization Tandem Mass Spectrometry with On-line Extraction
Open accessThe DOI matches its Crossref record.
Abstract
A liquid chromatographic-mass spectrometric method for the determination of cortisol in serum using atmospheric pressure electrospray ionization and tandem mass spectrometry is described. During sample preparation, 150 microl of serum were deproteinized with methanol/zinc sulfate followed by on-line solid phase extraction employing column switching. Tri-deuterated cortisol was used as the internal standard. The following transitions were monitored: cortisol, 363>309 m/z; d3-cortisol, 366>312 m/z. The total run-time was 5 minutes. The method proved linear (0-500 microg/l; r=0.999), precise (total coefficient of variation between 5.0% and 3.2% at a mean cortisol concentration of 15.1 microg/l and 269 microg/l, respectively; n=16) and specific with regard to relevant endogenous and exogenous steroids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Marik, P. E., Pastores, S. M., Annane, D., Meduri, G. U., Sprung, C. L., Arlt, W., Keh, D., Briegel, J., Beishuizen, A., Dimopoulou, I., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31817603ba · Cited by 912
“It is likely that the variation in assay characteristics might be even more significant in critically ill patients, especially those with septic shock (91, 92).”
BackgroundSelf-citationPredisposing Factors for Adrenal Insufficiency
Bornstein, S. R. (2009) · New England Journal of Medicine · doi:10.1056/nejmra0804635 · Cited by 356
Critical Illness-Related Corticosteroid Insufficiency
Marik, P. E. (2009) · Chest · doi:10.1378/chest.08-1149 · Cited by 299
for the CORTICUS Study Group, Briegel, J., Sprung, C. L., Annane, D., Singer, M., Keh, D., Moreno, R., Möhnle, P., Weiss, Y., Avidan, A., et al. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1627-9 · Cited by 93
Carvalho, V. M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.08.027 · Cited by 90
Metadata
- Authors
- Vogeser, M., Briegel, J., & Jacob, K.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2001-01-23
- Volume
- 39
- Issue
- 10
- Pages
- 944-7
- ISSN
- 1434-6621 (ISSN-L)
- OpenAlex
- W2143294886
- Cited by
- 50
- References
- 0
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Serum Cortisol by Isotope-Dilution Liquid-Chromatography Electrospray Ionization Tandem Mass Spectrometry with On-line Extraction. https://app.cochat.ai/papers/10.1515/cclm.2001.151
- The paper
- Vogeser, M., Briegel, J., & Jacob, K. (2001). Determination of Serum Cortisol by Isotope-Dilution Liquid-Chromatography Electrospray Ionization Tandem Mass Spectrometry with On-line Extraction. Clinical Chemistry and Laboratory Medicine. https://doi.org/10.1515/cclm.2001.151
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.