Preanalytical variability in laboratory testing: influence of the blood drawing technique
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The predominant technique used to draw blood for laboratory testing is a conventional straight needle attached to an evacuated tube system. However, alternative tools might be advantageous in exceptional circumstances. The use of butterfly devices has been traditionally discouraged for reasons of costs and due to the high risk of obtaining unsuitable samples, but there is no convincing evidence to support the latter indication. The purpose of this study was to compare results of hematological and clinical chemistry testing, after drawing blood into evacuated tubes, employing either a traditional 21-gauge straight needle or a 21-gauge butterfly device with 300-mm-grade polyvinyl chloride tubing. Blood samples and complete sets of data were successfully obtained for 30 consecutive outpatients. Of the 43 hematological and clinical chemistry parameters measured, means for paired samples collected by the two alternative drawing techniques did not differ significantly, except for serum sodium, white blood cells and platelets counts. Bland-Altman plots and limits-of-agreement analysis showed mean bias of between −7.2% and 1.7% and relative coefficients of variation ranging from 0.2% to 21.2%. The 95% agreement interval in the set of differences was acceptable and was mostly within the current analytical quality specifications for desirable bias. The rate of hemolysis in plasma was not statistically different between the two collection techniques. Taken together, the results of the present investigation suggest that, when a proper technique is used and within certain limitations, the butterfly device may be a reliable alternative to the conventional straight needle to draw blood for laboratory testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Current databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Effect of specimen collection on routine coagulation assays and D-dimer measurement
Lippi, G., & Guidi, G. C. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.036244 · Cited by 39 · cited 1×
“Most laboratory measures are not apparently influenced by the site of sample withdrawal, the presence of a tourniquet, or the time elapsed between blood sampling and analysis (9, 10).”
BackgroundSelf-citation
Cited by
Khan, S. Y., Kelher, M. R., Heal, J. M., Blumberg, N., Boshkov, L. K., Phipps, R., Gettings, K. F., McLaughlin, N. J., & Silliman, C. C. (2006) · Blood · doi:10.1182/blood-2006-04-017251 · Cited by 419
LACROIX, R., JUDICONE, C., PONCELET, P., ROBERT, S., ARNAUD, L., SAMPOL, J., & DIGNAT‐GEORGE, F. (2012) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2011.04610.x · Cited by 398
Influence of hemolysis on routine clinical chemistry testing
Lippi, G., Luca Salvagno, G., Montagnana, M., Brocco, G., & Cesare Guidi, G. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.054 · Cited by 344
“The frequency of in vitro hemolysis and additional preanalytical interference might be lowered by implementing standardized collection procedures, such as conventional straight needles and evacuated tube systems, instead of butterfly devices or syringes (5).”
BackgroundSelf-citationImpact of blood collection devices on clinical chemistry assays
Bowen, R. A. R., Hortin, G. L., Csako, G., Otañez, O. H., & Remaley, A. T. (2010) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.10.001 · Cited by 240
“241 mm internal diameter) needles, with the 21-gauge needle being standard for routine adult venipuncture [19,20,22].”
BackgroundInfluentialPhlebotomy, a bridge between laboratory and patient
Ialongo, C., & Bernardini, S. (2016) · Biochemia Medica · doi:10.11613/bm.2016.002 · Cited by 97
“However, with large bore size needles (like 21 G) the PVC tubing does not affect significantly the quality of laboratory testing (6).”
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2012) · Biochemia Medica · doi:10.11613/bm.2012.036 · Cited by 66
Self-citationFainting and hemolysis during blood sampling in youngsters: prevalence study
Vissers, D., Matthyssen, B., Truijen, S., Blommaert, S., Van De Velde, K., & Van Gaal, L. (2008) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2006.12.014 · Cited by 6
“There is however, evidence that the use of a butterfly device does not increase the risk of hemolysis compared to a conventional straight needle (Lippi et al., 2005).”
Background
Metadata
- Authors
- Lippi, G., Salvagno, G. L., Brocco, G., & Guidi, G. C.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2005-01-01
- Volume
- 43
- Issue
- 3
- Pages
- 319-25
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2143045146
- Cited by
- 56
- References
- 3
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.