CoChat

Preanalytical variability in laboratory testing: influence of the blood drawing technique

Lippi, Giuseppe, Salvagno, Gian Luca, Brocco, Giorgio, Guidi, Gian Cesare · 2005 · Clinical Chemistry and Laboratory Medicine (CCLM)
Cited by 56

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The predominant technique used to draw blood for laboratory testing is a conventional straight needle attached to an evacuated tube system. However, alternative tools might be advantageous in exceptional circumstances. The use of butterfly devices has been traditionally discouraged for reasons of costs and due to the high risk of obtaining unsuitable samples, but there is no convincing evidence to support the latter indication. The purpose of this study was to compare results of hematological and clinical chemistry testing, after drawing blood into evacuated tubes, employing either a traditional 21-gauge straight needle or a 21-gauge butterfly device with 300-mm-grade polyvinyl chloride tubing. Blood samples and complete sets of data were successfully obtained for 30 consecutive outpatients. Of the 43 hematological and clinical chemistry parameters measured, means for paired samples collected by the two alternative drawing techniques did not differ significantly, except for serum sodium, white blood cells and platelets counts. Bland-Altman plots and limits-of-agreement analysis showed mean bias of between −7.2% and 1.7% and relative coefficients of variation ranging from 0.2% to 21.2%. The 95% agreement interval in the set of differences was acceptable and was mostly within the current analytical quality specifications for desirable bias. The rate of hemolysis in plasma was not statistically different between the two collection techniques. Taken together, the results of the present investigation suggest that, when a proper technique is used and within certain limitations, the butterfly device may be a reliable alternative to the conventional straight needle to draw blood for laboratory testing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.2005.055

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 56

Metadata

Authors
Lippi, G., Salvagno, G. L., Brocco, G., & Guidi, G. C.
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2005-01-01
Volume
43
Issue
3
Pages
319-25
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2143045146
Cited by
56
References
3
FWCI
1.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.