CoChat

Increase in and clearance of cell-free plasma DNA in hemodialysis quantified by real-time PCR

García Moreira, Vanessa, de la Cera Martínez, Tamara, Gago González, Emilio, Prieto García, Belén, Alvarez Menéndez, Francisco V. · 2006 · Clinical Chemistry and Laboratory Medicine (CCLM)
Cited by 60

The DOI matches its Crossref record.

Abstract

BACKGROUND: Recently cell-free plasma DNA has been described as a marker of apoptosis during hemodialysis (HD), but little is known about how different dialysis membranes may contribute to this process or whether pre-HD levels are restored afterwards. Here we evaluate the influence of the dialysis membrane on cell-free plasma DNA levels and investigate the clearance of plasma circulating DNA after HD. METHODS: Cell-free plasma DNA was measured using a real-time quantitative PCR for the beta-globin gene. Reference values for plasma DNA were established in a group of 100 healthy voluntary blood donors. Pre- and post-HD levels were also measured in 30 patients with end-stage renal disease on regular HD (52 sessions; 104 samples). The sessions lasted for 2.5-5 h. Different dialysis membranes were compared: high-flux (n=37) vs. low-flux (n=15) and polysulfone (n=42) vs. modified cellulose (n=10). To determine the time at which pre-HD levels are restored, DNA was quantified in serial plasma samples obtained from 10 of these 30 patients, just before and immediately after HD, as well as at 30, 60 and 120 min after HD. RESULTS: Reference plasma DNA values for healthy blood donors ranged from 112 to 2452 gEq/mL (median 740 gEq/mL). Cell-free plasma DNA levels significantly increased during HD (Wilcoxon test for paired samples, p<0.0001), with increases of more than four-fold observed in 75% of the patients after HD. There was no significant linear association between the length of the HD session (between 2.5 and 5 h) and the increase in cell-free plasma DNA concentration (Pearson correlation). No significant differences were observed between different types of membranes (Mann-Whitney U-test). Plasma DNA returned to pre-HD levels by 30 min after HD, regardless of the starting concentration. CONCLUSIONS: Plasma DNA levels significantly increase after a conventional 2.5-5-h HD session. Therefore, HD patients require special consideration for correct interpretation of plasma DNA concentrations. This parameter can be considered a reliable diagnostic tool for certain pathologies when measured at least 30 min after a HD session without further complications. The different dialysis membranes used in this study had no influence on cell-free plasma DNA concentrations, so the level of circulating DNA is not an appropriate marker of dialysis membrane biocompatibility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.2006.252

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
García Moreira, V., de la Cera Martínez, T., Gago González, E., Prieto García, B., & Alvarez Menéndez, F. V.
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2006-01-01
Volume
44
Issue
12
Pages
1410-5
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2042878342
Cited by
60
References
0
FWCI
1.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.