An international comparability study to determine the sources of uncertainty associated with a non-competitive sandwich fluorescent ELISA
The DOI matches its Crossref record.
Abstract
BACKGROUND: Immunoassays allow the specific detection and quantitation of biological molecules in complex samples at physiologically relevant concentrations. However, there are concerns over the comparability of such techniques when the same assay is performed by different operators or laboratories. An international intercomparison study was performed to assess the uncertainty involved in the estimation of a protein cytokine concentration using a fluorescent ELISA. METHODS: The intercomparison study method was based on a non-competitive sandwich immunoassay with an enhancement step to generate a fluorescent readout. The intercomparison was performed in two phases, with the uncertainty of the instrument determined separately from that of the assay. The 11 laboratories participating in the study represented national metrology institutes or nominated expert laboratories. RESULTS: Participants were asked to determine an undisclosed concentration of interferon using a supplied standard. The mean participant estimate and experimental standard deviation of the mean was 3.54+/-0.22 mg/L, with the spread of data ranging around +/-35% of the mean. The quantitation range of the ELISA and of participants' instruments displayed large variation that contributed to the overall uncertainty. CONCLUSIONS: Identified sources of uncertainty within the ELISA methodology included pipetting, data fitting, model selection and instrument/plate variation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Meta-Analysis of Cytokines in Major Depression
Dowlati, Y., Herrmann, N., Swardfager, W., Liu, H., Sham, L., Reim, E. K., & Lanctôt, K. L. (2010) · Biological Psychiatry · doi:10.1016/j.biopsych.2009.09.033 · Cited by 4,729
A Meta-Analysis of Cytokines in Alzheimer's Disease
Swardfager, W., Lanctôt, K., Rothenburg, L., Wong, A., Cappell, J., & Herrmann, N. (2010) · Biological Psychiatry · doi:10.1016/j.biopsych.2010.06.012 · Cited by 1,108
Lai, K. S. P., Liu, C. S., Rau, A., Lanctôt, K. L., Köhler, C. A., Pakosh, M., Carvalho, A. F., & Herrmann, N. (2017) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp-2017-316201 · Cited by 433
Dinoff, A., Herrmann, N., Swardfager, W., Liu, C. S., Sherman, C., Chan, S., & Lanctôt, K. L. (2016) · PLOS ONE · doi:10.1371/journal.pone.0163037 · Cited by 332
Dinoff, A., Herrmann, N., Swardfager, W., & Lanctôt, K. L. (2017) · European Journal of Neuroscience · doi:10.1111/ejn.13603 · Cited by 323
“SMDs were chosen because of variability in absolute BDNF concentrations between assays used by different laboratories and between measures of BDNF in different components of blood (Noble et al., 2008).”
MethodExercise intervention and inflammatory markers in coronary artery disease: A meta-analysis
Swardfager, W., Herrmann, N., Cornish, S., Mazereeuw, G., Marzolini, S., Sham, L., & Lanctôt, K. L. (2012) · American Heart Journal · doi:10.1016/j.ahj.2011.12.017 · Cited by 91
Dinoff, A., Herrmann, N., Swardfager, W., Gallagher, D., & Lanctôt, K. L. (2018) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2018.08.021 · Cited by 50
Metadata
- Authors
- Noble, J. E., Wang, L., Cerasoli, E., Knight, A. E., Porter, R. A., Gray, E., Howe, C., Hannes, E., Corbisier, P., Wang, J., Wu, L., Altieri, I., Patriarca, M., Hoffman, A., Resch-Genger, U., Ebert, B., Voigt, J., Shigeri, Y., Vonsky, M. S., Konopelko, L. A., Gaigalas, A. K., & Bailey, M. J. A.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2008-01-01
- Volume
- 46
- Issue
- 7
- Pages
- 1033-45
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2005410220
- Cited by
- 31
- References
- 0
- FWCI
- 3.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.