HbA1c measurements from dried blood spots: validation and patient satisfaction
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: This study evaluates HbA1c measurements from dried blood spots collected on filter paper and compares HbA1c from filter paper (capillary blood) with HbA1c measured in venous blood. METHODS: Patient satisfaction was evaluated using a questionnaire. The performance with the filter paper method was assessed by comparing HbA1c results from EDTA-blood samples obtained via dried blood spots with HbA1c results obtained with freshly hemolyzed blood (routine HbA1c). Adult patients visiting the outpatient clinic for HbA1c analyses were recruited for the evaluation of dried blood spot sampling at home. Laboratory personnel collected a capillary blood sample on filter paper as well as a venous EDTA-blood sample. The participants collected another capillary blood sample at home and sent the dried filter paper back to the laboratory. Samples were analyzed with an immunoturbidimetric assay. RESULTS: Between-filter coefficient of variation was 1.8%. Filter paper HbA1c increased slightly during storage, particularly during the first 5 days. Filter paper HbA1c highly correlated with routine HbA1c (r=0.987). The evaluation of samples collected at home showed comparable HbA1c values by filter paper and routine sampling methods (n=93). Eighty-three percent of participants said they would like the filter method to be brought into practice. CONCLUSIONS: Home HbA1c sampling on filter paper is an acceptable sampling alternative for analysis of HbA1c.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Kennedy, L., Herman, W. H., Strange, P., Harris, A., & for the GOAL A1C Team (2006) · Diabetes Care · doi:10.2337/diacare.29.01.06.dc05-1058 · Cited by 189
Cited by
Significance of HbA1c Test in Diagnosis and Prognosis of Diabetic Patients
Sherwani, S. I., Khan, H. A., Ekhzaimy, A., Masood, A., & Sakharkar, M. K. (2016) · Biomarker Insights · doi:10.4137/bmi.s38440 · Cited by 1,381
Hemato-Critical Issues in Quantitative Analysis of Dried Blood Spots: Challenges and Solutions
De Kesel, P. M., Sadones, N., Capiau, S., Lambert, W. E., & Stove, C. P. (2013) · Bioanalysis · doi:10.4155/bio.13.156 · Cited by 277
The use of mass spectrometry to analyze dried blood spots
Wagner, M., Tonoli, D., Varesio, E., & Hopfgartner, G. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21441 · Cited by 262
Nelson, L. A., Greevy, R. A., Spieker, A., Wallston, K. A., Elasy, T. A., Kripalani, S., Gentry, C., Bergner, E. M., LeStourgeon, L. M., Williamson, S. E., et al. (2021) · Diabetes Care · doi:10.2337/dc20-0961 · Cited by 74
“The kits have been validated against venipuncture and are preferred by patients (24).”
Bardenheier, B. H., Wu, W.-C., Zullo, A. R., Gravenstein, S., & Gregg, E. W. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108726 · Cited by 16
Metadata
- Authors
- Fokkema, M. R., Bakker, A. J., de Boer, F., Kooistra, J., de Vries, S., & Wolthuis, A.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2009-01-01
- Volume
- 47
- Issue
- 10
- Pages
- 1259-64
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2067872658
- Cited by
- 73
- References
- 2
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: HbA1c measurements from dried blood spots: validation and patient satisfaction. https://app.cochat.ai/papers/10.1515/cclm.2009.274
- The paper
- Fokkema, M. R., Bakker, A. J., de Boer, F., Kooistra, J., de Vries, S., & Wolthuis, A. (2009). HbA1c measurements from dried blood spots: validation and patient satisfaction. Clinical Chemistry and Laboratory Medicine. https://doi.org/10.1515/cclm.2009.274
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.