Comparison of visual vs. automated detection of lipemic, icteric and hemolyzed specimens: can we rely on a human eye?
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Results from hemolyzed, icteric, and lipemic samples may be inaccurate and can lead to medical errors. These preanalytical interferences may be detected using visual or automated assessment. Visual inspection is time consuming, highly subjective and not standardized. Our aim was to assess the comparability of automated spectrophotometric detection and visual inspection of lipemic, icteric and hemolyzed samples. METHODS: This study was performed on 1727 routine biochemistry serum samples. Automated detection was performed using the Olympus AU2700 analyzer. We assessed: 1) comparability of visual and automated detection of lipemic, icteric and hemolyzed samples, 2) precision of automated detection, and 3) inter-observer variability for visual inspection. RESULTS: Weighted kappa coefficients for comparability of visual and automated detection were: 0.555, 0.529 and 0.638, for lipemic, icteric and hemolyzed samples, respectively. The precision for automated detection was high for all interferences, with the exception of samples being only slightly lipemic. The best overall agreement between observers was present in assessing lipemia (mean weighted kappa=0.698), whereas the lowest degree of agreement was observed in assessing icterus (mean weighted kappa=0.476). CONCLUSIONS: Visual inspection of lipemic, icteric and hemolyzed samples is highly unreliable and should be replaced by automated systems that report serum indices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influence of hemolysis on routine clinical chemistry testing
Lippi, G., Luca Salvagno, G., Montagnana, M., Brocco, G., & Cesare Guidi, G. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.054 · Cited by 344 · cited 2×
“Unsuitable specimens may significantly affect the accuracy of many clinical chemistry and hematology analyses (10, 11).”
Background
Cited by
Interrater reliability: The kappa statistic
McHugh, M. L. (2012) · Biochemia Medica · doi:10.11613/bm.2012.031 · Cited by 19,877
Lipemia: causes, interference mechanisms, detection and management
Nikolac, N. (2014) · Biochemia Medica · doi:10.11613/bm.2014.008 · Cited by 290
Self-citationLippi, G., Cervellin, G., & Mattiuzzi, C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.022 · Cited by 66
“First, visual inspection is arbitrary, cannot be standardized and is characterized by small inter-observer agreement (31), so that it should be replaced by automated systems that report serum indices.”
BackgroundMeasuring haemolysis in cattle serum by direct UV–VIS and RGB digital image-based methods
Larrán, B., López-Alonso, M., Miranda, M., Pereira, V., Rigueira, L., Suárez, M. L., & Herrero-Latorre, C. (2022) · Scientific Reports · doi:10.1038/s41598-022-17842-4 · Cited by 7
Metadata
- Authors
- Simundic, A.-M., Nikolac, N., Ivankovic, V., Ferenec-Ruzic, D., Magdic, B., Kvaternik, M., & Topic, E.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2009-01-01
- Volume
- 47
- Issue
- 11
- Pages
- 1361-5
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2010067658
- Cited by
- 113
- References
- 1
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.