The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Lipemia: causes, interference mechanisms, detection and management
Open accessAbstract
In the clinical laboratory setting, interferences can be a significant source of laboratory errors with potential to cause serious harm for the patient. After hemolysis, lipemia is the most frequent endogenous interference that can influence results of various laboratory methods by several mechanisms. The most common preanalytical cause of lipemic samples is inadequate time of blood sampling after the meal or parenteral administration of synthetic lipid emulsions. Although the best way of detecting the degree of lipemia is measuring lipemic index on analytical platforms, laboratory experts should be aware of its problems, like false positive results and lack of standardization between manufacturers. Unlike for other interferences, lipemia can be removed and measurement can be done in a clear sample. However, a protocol for removing lipids from the sample has to be chosen carefully, since it is dependent on the analytes that have to be determined. Investigation of lipemia interference is an obligation of manufacturers of laboratory reagents; however, several literature findings report lack of verification of the declared data. Moreover, the acceptance criteria currently used by the most manufacturers are not based on biological variation and need to be revised. Written procedures for detection of lipemia, removing lipemia interference and reporting results from lipemic samples should be available to laboratory staff in order to standardize the procedure, reduce errors and increase patient safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yaşlı Kadınlarda Üreme Sağlığı
Kokanalı, D., & Engin Üstün, Y. (n.d.) · DergiPark (Istanbul University) · Cited by 170,090
Current databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987
Garvey, W. T., Kwon, S., Zheng, D., Shaughnessy, S., Wallace, P., Hutto, A., Pugh, K., Jenkins, A. J., Klein, R. L., & Liao, Y. (2003) · Diabetes · doi:10.2337/diabetes.52.2.453 · Cited by 607
Tate, J. R., & Ward, G. (2004) · PubMed · Cited by 548
Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories
Lippi, G., Blanckaert, N., Bonini, P., Green, S., Kitchen, S., Palicka, V., Vassault, A. J., & Plebani, M. (2008) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2008.170 · Cited by 466
Preanalytical quality improvement: from dream to reality
Lippi, G., Chance, J. J., Church, S., Dazzi, P., Fontana, R., Giavarina, D., Grankvist, K., Huisman, W., Kouri, T., Palicka, V., et al. (2011) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.600 · Cited by 388
Graphical comparisons of interferences in clinical chemistry instrumentation.
Glick, M. R., Ryder, K. W., & Jackson, S. A. (1986) · Clinical Chemistry · doi:10.1093/clinchem/32.3.470 · Cited by 289
Interference with clinical laboratory analyses
Kroll, M. H., & Elin, R. J. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.11.1996 · Cited by 269
Criteria for judging precision and accuracy in method development and evaluation
Westgard, J. O., Carey, R. N., & Wold, S. (1974) · Clinical Chemistry · doi:10.1093/clinchem/20.7.825 · Cited by 236
Preanalytical quality improvement: in quality we trust
Lippi, G., Becan-McBride, K., Behúlová, D., Bowen, R. A., Church, S., Delanghe, J., Grankvist, K., Kitchen, S., Nybo, M., Nauck, M., et al. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0597 · Cited by 236
Self-citation
Cited by
Burla, B., Arita, M., Arita, M., Bendt, A. K., Cazenave-Gassiot, A., Dennis, E. A., Ekroos, K., Han, X., Ikeda, K., Liebisch, G., et al. (2018) · Journal of Lipid Research · doi:10.1194/jlr.s087163 · Cited by 312
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Picheth, G., & Guidi, G. C. (2015) · Journal of Medical Biochemistry · doi:10.2478/jomb-2014-0043 · Cited by 102
Metadata
- Authors
- Nikolac, N.
- Venue
- Biochemia Medica
- Published
- 2014
- Volume
- 24
- Issue
- 1
- Pages
- 57-67
- ISSN
- 1330-0962 (ISSN-L)
- 1846-7482
- OpenAlex
- W2097093707
- Cited by
- 290
- References
- 31
- FWCI
- 8.55
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lipemia: causes, interference mechanisms, detection and management. https://app.cochat.ai/papers/10.11613/bm.2014.008
- The paper
- Nikolac, N. (2014). Lipemia: causes, interference mechanisms, detection and management. Biochemia Medica. https://doi.org/10.11613/bm.2014.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.