CoChat

The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: a new tool to assess the acceptability of intensive care unit testing

Cembrowski, George S., Tran, David V., Higgins, Trefor N. · 2010 · cclm
Cited by 30

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Most estimates of biologic variation (s b) are based on periodically acquiring and storing specimens, followed by analysis within a single analytic run. We demonstrate for many intensive care unit (ICU) tests, only patient results need be statistically analyzed to provide reliable estimates of s b. Methods: Over 11 months, approximately 28,000 blood gas measurements (including electrolyte panels and glucose) were performed on one of two Radiometer ABL800 FLEX analyzers (Radiometer, Copenhagen, Denmark) from 1676 ICU patients. We tabulated the measurements of paired intra-patient blood samples drawn within 24 h of each other. After removal of outliers, we calculated the standard deviations of duplicates (SDD) of the intra-patient pairs grouped in 2-h intervals: 0–2 h, 2–4 h, 4–6 h, … 20–22 h and 22–24 h. The SDDs were then regressed against the time intervals of 2–14 h; extrapolation to zero time represents the sum of s b and short-term analytic variation (s a). Results: Substitution of experimentally derived analytic error permitted the calculation of coefficient of variation (biologic) (CV b) (100 s b/mean): pH, 0.3%; pCO 2, 5.7%; pO 2, 13%; Na+, 0.6%; K+, 4.8%; Cl–, 0.8%; HCO 3 –, 3.2%; iCa++, 2.4%; and glucose, 10.3%. The CV b of the electrolytes very closely matches the lowest estimates obtained in the usual manner. Conclusions: Derivation of the ratio of biologic to analytic variation indicates that the ABL800 is extremely suitable for ICU testing. This analysis should be extended to other point of care instrument systems. Clin Chem Lab Med 2010;48:1447–54.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.2010.286

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 30

Metadata

Authors
Cembrowski, G. S., Tran, D. V., & Higgins, T. N.
Venue
cclm
Published
2010-08-18
Volume
48
Issue
10
Pages
1447-1454
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W1999247754
Cited by
30
References
2
FWCI
2.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: a new tool to assess the acceptability of intensive care unit testing. https://app.cochat.ai/papers/10.1515/cclm.2010.286
The paper
Cembrowski, G. S., Tran, D. V., & Higgins, T. N. (2010). The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: a new tool to assess the acceptability of intensive care unit testing. cclm. https://doi.org/10.1515/cclm.2010.286

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.