An online movement and tremor identification algorithm for evaluation during deep brain stimulation
Open accessThe DOI matches its Crossref record; 10 of the 11 references it cites were found in a registry or an index; 4 of the 9 sources its claims cite were checked for support.
Abstract
Abstract INTRODUCTION: Deep brain stimulation (DBS) is widely used to alleviate symptoms of movement disorders. During intraoperative stimulation the influence of active or passive movements on the neuronal activity is often evaluated but the evaluation remains mostly subjective. The objective of this paper is to investigate the potential of a previously developed Weighted-frequency Fourier Linear combiner and Kalman filter-based recursive algorithm to identify tremor phases and types. METHODS: Ten accelerometer recordings from eight patients were acquired during DBS from which 186 phases were manually annotated into: rest, postural and kinetic phase without tremor, and rest, postural and kinetic phase with tremor. The method first estimates the instantaneous tremor frequency and then decomposes the motion signal into voluntary and tremorous parts. The tremorous part is used to quantify tremor and the voluntary part to differentiate rest, postural and kinetic phases. RESULTS: Instantaneous tremor frequency and amplitude are successfully tracked online. The overall accuracy for tremorous phases only is 89.1% and 76.3% when also non-tremorous phases are considered. Two main misclassification cases are identified and further discussed. CONCLUSION: The results demonstrate the potential of the developed algorithm as an online tremorous movement classifier. It would benefit from a more advanced tremor detector but nevertheless the obtained digital biomarkers offer an evidence-based analysis and could optimize the efficacy of DBS treatment.
Overview
CoChat Summary
TL;DR
This paper presents a recursive online algorithm that separates tremor from voluntary movement during DBS using accelerometer recordings, then classifies rest, postural, and kinetic phases. On 10 recordings from 8 patients, it tracked instantaneous tremor frequency and amplitude online and achieved 89.1% accuracy for tremorous phases only and 76.3% when non-tremorous phases were included.
Key findings
- The algorithm successfully tracked instantaneous tremor frequency and amplitude online, and the authors state it can characterize tremor by estimating these quantities.
- For phase classification with tremorous and non-tremorous phases merged, the overall accuracy was 85.5%.
- For the full six-class classification into rest, postural, and kinetic phases with/without tremor, the overall accuracy was 76.3%.
- When a “perfectly accurate” tremor detector is assumed, the paper states the algorithm would be applied only to tremorous phases and would yield 89.1% accuracy on the given data.
Methods
- Design: Proof-of-concept clinical study evaluating a previously developed Weighted-frequency Fourier Linear combiner (WFLC) plus Kalman filter-based recursive algorithm for online tremor and movement classification during DBS surgery.
- Data/sample: 10 accelerometer recordings from 8 patients (4 ET and 4 PD; mean age 67.3 ± 10.0 years), with 186 manually labeled phases across rest, postural, and movement conditions, each with/without tremor.
- Main analysis: Accelerometer signals sampled at 100 Hz were band-pass filtered (3–8 Hz), reduced to one dimension via PCA, then used to estimate instantaneous tremor frequency, decompose the signal into tremorous and voluntary parts, and classify tremor presence and phase type by thresholding; performance was compared to manual labels.
Limitations
- The paper states that distinguishing non-tremorous rest from non-tremorous postural phases is “obviously not feasible” without additional information; this is a stated methodological limitation.
- The authors note the algorithm is “well suited for the characterization of tremor but is not yet adapted for its detection” and would benefit from a more advanced tremor detector before clinical use; this is stated in the paper.
- Evident from the text: the dataset is small and heterogeneous (8 patients, 10 recordings, and some recordings lacked either video or accelerometer data), which likely limits generalizability, though the paper does not explicitly frame this as a limitation.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
3 Valid · 1 Not valid · 2 Not checked · 29 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Clinical evaluations are usually done semi-quantitatively via clinical rating scales such as the TETRAS [5] or the Unified Parkinson's Disease rating scale [6] with the inherent interrater variability.”
§ An online movement and tremor identification algorithm for evaluation during deep brain stimulation > 1 Introduction
What the sources say
- Supportedcites [5] 5. Elble R, Comella C, Fahn S, et al. Reliability of a new scale for essential tremor. Mov Disord. 2012;27(12):1567-1569. source
The Introduction identifies TETRAS as a clinical rating scale for essential tremor. The Results report inter-rater reliability across its items, with lower reliability for face, voice, lower-limb and trunk tremor, supporting the point that ratings can vary between raters. UPDRS has a separate citation in the citing sentence and is not attributed to this paper. (LLM, conf=0.88)
- Not matchedcites [6] 6. Fahn S, Elton RL. Unified Parkinson's disease rating scale. In: Fahn S, Marsden CD, Goldstein M, eds. Recent Developments in Parkinson's Disease. Macmillian; 1987:153- 163.
We searched by its title and found no matching paper.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The misclassification of postural phases in rest phases is clearly noticeable.”
§ An online movement and tremor identification algorithm for evaluation during deep brain stimulation > 3 Results
boosted- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Instantaneous tremor frequency and amplitude are successfully tracked online.”
- Also stated in: § 3 Results · boosted
“Tremorous movement (Figure 1.a, recording #3), clearly distinguishable with its peaks in the frequency domain, is successfully estimated in the time domain including its frequency and amplitude.”
- Also stated in: § 4 Discussion · plain
“The presented recursive online algorithm successfully characterizes tremor by estimating its instantaneous frequency and amplitude.”
§ An online movement and tremor identification algorithm for evaluation during deep brain stimulation > Abstract
boostedn = 8- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
- Also stated in: § 3 Results · boosted
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The error matrix for the classification of rest, postural and kinetic motion types where phases with and without tremor are merged has an overall accuracy of 85.5% (see Figure 2).”
§ An online movement and tremor identification algorithm for evaluation during deep brain stimulation > 3 Results
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“A second inaccurate estimation regards voluntary movement without tremor (kinetic) being estimated as movement with tremor (kinetic tremor).”
§ An online movement and tremor identification algorithm for evaluation during deep brain stimulation > 3 Results
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on 2 assumptions not shown here.
13 more claims
Create a free account to see all 35 claims and every source verdict.
- It may state two separate claims as one. 10
- Probably not a substantial claim. 11
Citations
Cites
Monitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623 · cited 1×
“We [7] and others [8-9] have previously shown that quantitative objective digital tremor biomarkers can support neurosurgeons and neurologists and generate more precise and continuous data.”
BackgroundRecent Developments in Parkinson's Disease
Greenfield, S. A. (1987) · Neurochemistry International · doi:10.1016/0197-0186(87)90185-9 · Cited by 540
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 3×
“Especially the computational requirements for the WFLC are very low due to its simplicity [10].”
InfluentialReliability of a new scale for essential tremor
Elble, R., Comella, C., Fahn, S., Hallett, M., Jankovic, J., Juncos, J. L., LeWitt, P., Lyons, K., Ondo, W., Pahwa, R., et al. (2012) · Movement Disorders · doi:10.1002/mds.25162 · Cited by 244 · cited 1×
“Clinical evaluations are usually done semi-quantitatively via clinical rating scales such as the TETRAS [5] or the Unified Parkinson’s Disease rating scale [6] with the inherent interrater variability.”
MethodIdentification of the target neuronal elements in electrical deep brain stimulation
Holsheimer, J., Demeulemeester, H., Nuttin, B., & de Sutter, P. (2000) · European Journal of Neuroscience · doi:10.1046/j.1460-9568.2000.01306.x · Cited by 128
Analyzing the dynamics of hand tremor time series
Gantert, C., Honerkamp, J., & Timmer, J. (1992) · Biological Cybernetics · doi:10.1007/bf00204112 · Cited by 74 · cited 1×
“We [7] and others [8-9] have previously shown that quantitative objective digital tremor biomarkers can support neurosurgeons and neurologists and generate more precise and continuous data.”
Background“Asleep” Deep Brain Stimulation Surgery: A Critical Review of the Literature
Chen, T., Mirzadeh, Z., & Ponce, F. A. (2017) · World Neurosurgery · doi:10.1016/j.wneu.2017.05.042 · Cited by 64 · cited 1×
“Although DBS application under full anaesthesia is currently being researched [3], the majority of interventions are performed with awake patients.”
BackgroundDeep Brain Stimulation: Emerging Tools for Simulation, Data Analysis, and Visualization
Wårdell, K., Nordin, T., Vogel, D., Zsigmond, P., Westin, C., Hariz, M. I., & Hemm, S. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.834026 · Cited by 35 · cited 1×
“Deep Brain Stimulation (DBS) [1] has become one of the most important neurostimulation therapies for movement disorders such as Parkinson’s disease (PD) and essential tremor (ET) to alleviate tremor among other symptoms [2].”
Self-citationShah, A., Coste, J., Lemaire, J.-J., Taub, E., Schüpbach, W. M. M., Pollo, C., Schkommodau, E., Guzman, R., & Hemm-Ode, S. (2017) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1559-9 · Cited by 21 · cited 1×
“We [7] and others [8-9] have previously shown that quantitative objective digital tremor biomarkers can support neurosurgeons and neurologists and generate more precise and continuous data.”
BackgroundSelf-citationNew electrophysiological mapping combined with MRI in parkinsonian’s subthalamic region
Coste, J., Ouchchane, L., Sarry, L., et al. (2009) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2009.06698.x · Cited by 18 · cited 1×
“During DBS surgery, MER recordings were performed along two trajectories per hemisphere at several positions before and behind the target position identified on preoperative images [11].”
Self-citation
Research works printed but not linked: 1
- [12]12. Bodenham D. Adaptive Filtering and Change Detection for Streaming Data. PH.D. Thesis. Imperial College, London, 2012. Figure 3: Error matrix for the classification into rest, postural, kinetic tremor, and rest, postural, kinetic phase without tremor. The overall accuracy is 76.3%. cdbme_2022_8_2.pdf 108 8/29/2022 5:45:32 PM
Metadata
- Authors
- Bourgeois, F., Pambakian, N., Coste, J., Lange, I. D., Lemaire, J.-J., Schkommodau, E., & Hemm, S.
- Affiliations
- FHNW University of Applied Sciences and Arts Northwestern Switzerland (CH)
- STIL B.V., Delft , Netherlands
- Centre National de la Recherche Scientifique (FR)
- Corresponding author
- Bourgeois, Frédéric
- Venue
- Current Directions in Biomedical Engineering
- Publisher
- Walter de Gruyter GmbH
- Published
- 2022-08-01
- Volume
- 8
- Issue
- 2
- Pages
- 105-108
- ISSN
- 2364-5504 (ISSN-L)
- OpenAlex
- W4294218396
- Cited by
- 0
- References
- 11
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Locations
- Current Directions in Biomedical Engineering (publishedVersion, cc-by)
- HAL (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- deep brain stimulation, tremor detection, tremor classification, Kalman filter, recursive algorithm, digital biomarkers, movement disorders, intraoperative stimulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.