The Use of a Continuous Glucose Monitoring System in Hypoglycemic Disorders
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To evaluate the use of a continuous glucose monitoring system (CGMS) in the evaluation and treatment of infants and children with hypoglycemic disorders. METHODS: Patients with hypoglycemic disorders wore the CGMS device in the Pediatric Clinic Research Center during their evaluation and treatment. Capillary blood glucose (CBG) values were obtained at least 3 times each day and entered into the device for calibration purposes. We evaluated the number of hypoglycemic episodes below 3.3 mmol/l (60 mg/dl) detected by CGMS compared to CBG values and characterized episodes by their duration and intensity. RESULTS: Five patients with hypoglycemic disorders were included in the study. There were a total of 13,369 sensor points, 343 paired sensor and CBG data points, and 57 days included. A total of 180 episodes of hypoglycemia occurred in these five patients, with an average duration of 55 +/- 13 minutes. Using a cut-off of 3.3 mmol/l (60 mg/dl) for hypoglycemia, the sensor had a sensitivity of 65.4%, specificity of 90.6%, and false positive rate of 42.9%. The positive and negative predictive values were 57.1% and 93.2%, respectively. CONCLUSION: CGMS is a useful adjunct in the diagnosis and evaluation of hypoglycemia, and for documentation of euglycemia in these patients following therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Glycemic Characteristics in Continuously Monitored Patients With Type 1 and Type 2 Diabetes
Bode, B. W., Schwartz, S., Stubbs, H. A., & Block, J. E. (2005) · Diabetes Care · doi:10.2337/diacare.28.10.2361 · Cited by 137
Continuous glucose monitoring for hypoglycaemia in children: perspectives in 2020
Worth, C., Dunne, M., Ghosh, A., Harper, S., & Banerjee, I. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13029 · Cited by 37
“Despite this, CGM allows for a dynamic view of hypoglycaemia and enables clinicians to measure responses to treatment.(26,56) Alsaffar et al used a factory-calibrated flash CGM device in a”
MethodRayannavar, A., Elci, O. U., Mitteer, L., & De León, D. D. (2019) · Hormone Research in Paediatrics · doi:10.1159/000506230 · Cited by 31
Watanabe, T., Ozawa, A., Ishii, S., Tomaru, T., Shibusawa, N., Saito, T., Yamada, E., Horiguchi, K., Nakajima, Y., Matsumoto, S., et al. (2018) · Endocrine Journal · doi:10.1507/endocrj.ej16-0387 · Cited by 22
Metadata
- Authors
- Conrad, S. C., Mastrototaro, J. J., & Gitelman, S. E.
- Venue
- Journal of Pediatric Endocrinology and Metabolism
- Publisher
- Walter de Gruyter GmbH
- Published
- 2004-01
- Volume
- 17
- Issue
- 3
- Pages
- 281-8
- ISSN
- 0334-018X (ISSN-L)
- 2191-0251
- OpenAlex
- W2315009930
- Cited by
- 31
- References
- 0
- FWCI
- 2.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Use of a Continuous Glucose Monitoring System in Hypoglycemic Disorders. https://app.cochat.ai/papers/10.1515/jpem.2004.17.3.281
- The paper
- Conrad, S. C., Mastrototaro, J. J., & Gitelman, S. E. (2004). The Use of a Continuous Glucose Monitoring System in Hypoglycemic Disorders. Journal of Pediatric Endocrinology and Metabolism. https://doi.org/10.1515/jpem.2004.17.3.281
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.