Glycemic Characteristics in Continuously Monitored Patients With Type 1 and Type 2 Diabetes
Open accessAbstract
OBJECTIVE—The purpose of this study was to generate normative values for periods of euglycemia as well as for daily patterns of glycemic excursions in patients with type 1 and type 2 diabetes monitored continuously for a maximum period of 21 days and blinded to glucose levels. RESEARCH DESIGN AND METHODS—This was a multicenter, prospective observational study in which 101 consecutive patients with type 1 (n = 60) or type 2 (n = 41) diabetes underwent blinded continuous glucose monitoring. Serial glucose measurements were divided into periods of euglycemia (70–180 mg/dl), hyperglycemia (>180 mg/dl), and hypoglycemia (<70 mg/dl). The proportions of time patients were hypoglycemic, euglycemic, and hyperglycemic and the total areas under the curves (AUCs) were determined. RESULTS—During the observation period the 101 subjects contributed an average 287 ± 132 h of continuous glucose values. Subjects remained in the euglycemic range for ∼63% of the total day, were hypoglycemic 8%, and were hyperglycemic 29%. Hypoglycemia was more prevalent nocturnally (11 vs. 7%) and hyperglycemia diurnally (31 vs. 25%). Compared with subjects with type 2 diabetes, type 1 diabetic subjects had more frequent hypoglycemic episodes per day (2.1 vs. 1.0; P < 0.001) that were of longer duration (1.1 vs. 0.7 h; P < 0.0001), reflecting a greater number of hours per day in the hypoglycemic range (2.3 vs. 1.0 h; P < 0.0001). The mean hypoglycemic AUC values were >150% higher for type 1 compared with type 2 diabetic subjects (41 vs. 16, respectively; P < 0.0001). CONCLUSIONS—These normative data will assist in study and sample size planning for future investigations of continuous glucose monitoring and allow for qualitative comparisons with trials of therapeutic interventions aimed at reducing the occurrence of glycemic excursions.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Even with frequent BGM, most people with type 1 diabetes have undetected and unacceptably high frequency of hyper- and hypoglycemia.
“However, even with frequent BGM, most people with type 1 diabetes will have undetected and an unacceptable high frequency of hyper-and hypoglycemia (72).”
From The management of type 1 diabetes in adults. A consensus report by the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD) (2021) · cites this paper as [72]
The Results report frequent fingerstick testing (about nine times daily), substantial hyperglycemia and more than two hours per day of hypoglycemia among subjects with type 1 diabetes. The discussion says nocturnal hypoglycemia often goes undetected by standard monitoring and postprandial hyperglycemia is underappreciated by conventional monitoring. But the paper describes these patterns in an intensively managed study cohort; it does not establish that most people with type 1 diabetes experience both at this frequency. (LLM, conf=0.85)
Experimental — accuracy not yet measuredSelf-monitoring of blood glucose is associated with an improvement in control of HbA1c, but the information it provides is limited, and people living with diabetes may be unaware of their glucose levels or trends, leading to an increased risk of hypoglycemic events.
“Of note, although self-monitoring of blood glucose is associated with an improvement in control of HbA1c, the information it provides is limited, and people living with diabetes may be unaware of their glucose levels or trends, leading to an increased risk of hypoglycemic events.2-4”
From Importance of FDA-integrated continuous glucose monitors to ensure accuracy of continuous glucose monitoring (2025) · cites this paper as [4]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667 · see citing works
Analysis of serial measurements in medical research.
Matthews, J. N. S., Altman, D. G., Campbell, M. J., & Royston, P. J. (1990) · BMJ · doi:10.1136/bmj.300.6719.230 · Cited by 3,137 · see citing works
(1994) · The Journal of Pediatrics · doi:10.1016/s0022-3476(94)70190-3 · Cited by 1,654 · see citing works
Long-Term Complications of Diabetes Mellitus
Nathan, D. M. (1993) · New England Journal of Medicine · doi:10.1056/nejm199306103282306 · Cited by 1,495 · see citing works
Nowy rok, stare problemy, ale i nowe możliwości
Czupryniak, L. (2014) · Via Medica Journals · Cited by 1,192 · see citing works
The Effect of Intensive Diabetes Therapy on the Development and Progression of Neuropathy
The Diabetes Control and Complications Trial Research Group. (1995) · Annals of Internal Medicine · doi:10.7326/0003-4819-122-8-199504150-00001 · Cited by 602 · see citing works
Limitations of Conventional Methods of Self-Monitoring of Blood Glucose
Boland, E. A., Monsod, T. P., DeLucia, M. C., Brandt, C., Fernando, S. K., & Tamborlane, W. V. (2001) · Diabetes Care · doi:10.2337/diacare.24.11.1858 · Cited by 422 · see citing works
Hoey, H., Aanstoot, H., Chiarelli, F., Daneman, D., Danne, T., Dorchy, H., Fitzgerald, M., Garandeau, P., Greene, S. A., Holl, R. W., et al. (2001) · Diabetes Care · doi:10.2337/diacare.24.11.1923 · Cited by 363 · see citing works
Standards of medical care for patients with diabetes mellitus
(1989) · The Journal of the American Osteopathic Association · doi:10.1515/jom-1989-890715 · Cited by 361 · see citing works
Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home Use
Gross, T. M., Bode, B. W., EINHORN, D. F., Kayne, D. M., Reed, J. H. C., White, N. H., & Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091500316737 · Cited by 303 · see citing works
Self-citationThe Cost to Health Plans of Poor Glycemic Control
Gilmer, T., O’Connor, P. J., Manning, W. G., & Rush, W. A. (1997) · Diabetes Care · doi:10.2337/diacare.20.12.1847 · Cited by 303 · see citing works
Evans, J. M. M., Newton, R. W., Ruta, D. A., MacDonald, T. M., Stevenson, R. J., & Morris, A. D. (1999) · BMJ · doi:10.1136/bmj.319.7202.83 · Cited by 283 · see citing works
Chico, A., Vidal-Ríos, P., Subirà, M., & Novials, A. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1153 · Cited by 235 · see citing works
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232 · see citing works
Self-citationLudvigsson, J., & Hanås, R. (2003) · PEDIATRICS · doi:10.1542/peds.111.5.933 · Cited by 227 · see citing works
Feldman, B., Brazg, R., Schwartz, S. L., & Weinstein, R. L. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322526978 · Cited by 184 · see citing works
Self-citationGarg, S. K., Schwartz, S. L., & Edelman, S. V. (2004) · Diabetes Care · doi:10.2337/diacare.27.3.734 · Cited by 161 · see citing works
Self-citationHay, L. C., Wilmshurst, E. G., & Fulcher, G. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503763816427 · Cited by 143 · see citing works
Hershey, T. G., Bhargava, N., Sadler, M., White, N. H., & Craft, S. (1999) · Diabetes Care · doi:10.2337/diacare.22.8.1318 · Cited by 137 · see citing works
KAUFMAN, F. R., Austin, J., Neinstein, A. B., Jeng, L., Halvorson, M., Devoe, D. J., & Pitukcheewanont, P. (2002) · The Journal of Pediatrics · doi:10.1067/mpd.2002.129175 · Cited by 136 · see citing works
Amin, R., Ross, K., Acerini, C. L., Edge, J. A., Warner, J., & Dunger, D. B. (2003) · Diabetes Care · doi:10.2337/diacare.26.3.662 · Cited by 106 · see citing works
Social deprivation and mortality in adults with diabetes mellitus
Robinson, N., Lloyd, C. E., & Stevens, L. K. (1998) · Diabetic Medicine · doi:10.1002/(sici)1096-9136(199803)15:3 · Cited by 87 · see citing works
Salardi, S., Zucchini, S., Santoni, R., Ragni, L., Gualandi, S. C., Cicognani, A., & CACCIARI, E. (2002) · Diabetes Care · doi:10.2337/diacare.25.10.1840 · Cited by 87 · see citing works
Hypoglycaemia and the neonatal brain
Hawdon, J. M. (1999) · European Journal of Pediatrics · doi:10.1007/pl00014319 · Cited by 84 · see citing works
Adverse events in intensively treated children and adolescents with type 1 diabetes
Nordfeldt, S., & Ludvigsson, J. (1999) · Acta Paediatrica · doi:10.1111/j.1651-2227.1999.tb01016.x · Cited by 82 · see citing works
Use of the GlucoWatch Biographer in Children With Type 1 Diabetes
Chase, H. P., Roberts, M. D., Wightman, C., KLINGENSMITH, G. J., Garg, S. K., Wyhe, M. V., Desai, S. P., Harper, W., Lopatin, M., Bartkowiak, M., et al. (2003) · PEDIATRICS · doi:10.1542/peds.111.4.790 · Cited by 81 · see citing works
Schaepelynck-Belicar, P., Vague, P., Simonin, G., & Lassmann-Vague, V. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70076-9 · Cited by 78 · see citing works
Schiaffini, R., Ciampalini, P., Fierabracci, A., Spera, S., Borrelli, P., Bottazzo, G. F., & Crinò, A. (2002) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.309 · Cited by 77 · see citing works
Assessment of hypoglycaemia awareness using continuous glucose monitoring
Kubiak, T., Hermanns, N., Schreckling, H.-J., Kulzer, B., & Haak, T. (2004) · Diabetic Medicine · doi:10.1111/j.1464-5491.2004.1136.x · Cited by 64 · see citing works
Clinical Utility of the Continuous Glucose Monitoring System
Bode, B. W. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214104 · Cited by 64 · see citing works
Self-citationSkyler, J. S. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214069 · Cited by 38 · see citing works
The Use of a Continuous Glucose Monitoring System in Hypoglycemic Disorders
Conrad, S. C., Mastrototaro, J. J., & Gitelman, S. E. (2004) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem.2004.17.3.281 · Cited by 32 · see citing works
Antiobesity pharmacotherapy in the management of Type 2 diabetes
Scheen, A. J., & Lef�bvre, P. J. (2000) · Diabetes/Metabolism Research and Reviews · doi:10.1002/(sici)1520-7560(200003/04)16:2 · Cited by 29 · see citing works
Tavris, D. R., & Shoaibi, A. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/1520915041705956 · Cited by 28 · see citing works
Using the Continuous Glucose Monitoring System to Improve the Management of Type 1 Diabetes
Bode, B. W., & Hirsch, I. B. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214113 · Cited by 19 · see citing works
Self-citationDoes continuous glucose monitoring have clinical utility in contemporary management of diabetes?
Cameron, F. J., & Ambler, G. R. (2004) · Journal of Paediatrics and Child Health · doi:10.1111/j.1440-1754.2004.00307.x · Cited by 18 · see citing works
Eastman, R. C., Leptien, A. D., & Chase, H. P. (2003) · Pediatric Diabetes · doi:10.1034/j.1399-5448.2003.00011.x · Cited by 15 · see citing works
Continuous glucose monitoring in type 1 diabetes
WEINZIMER, S. A., Tamborlane, W. V., Chase, H. P., & Garg, S. K. (2004) · Current Diabetes Reports · doi:10.1007/s11892-004-0063-z · Cited by 10 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559 · see citing works
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetes Care · doi:10.2337/dci21-0043 · Cited by 699 · see citing works
Agiostratidou, G., Anhalt, H., Ball, D., Blonde, L., Gourgari, E., Harriman, K. N., Kowalski, A. J., Madden, P., McAuliffe-Fogarty, A. H., McElwee-Malloy, M., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1624 · Cited by 397 · see citing works
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313 · see citing works
Hovorka, R., Kumareswaran, K., Harris, J., Allen, J. M., Elleri, D., Xing, D., Kollman, C., Nodale, M., Murphy, H. R., Dunger, D. B., et al. (2011) · BMJ · doi:10.1136/bmj.d1855 · Cited by 244 · see citing works
Fonseca, V. A., Grunberger, G., Anhalt, H., Bailey, T. S., Blevins, T., Garg, S. K., Handelsman, Y., Hirsch, I. B., Orzeck, E. A., Roberts, V. L., et al. (2016) · Endocrine Practice · doi:10.4158/ep161392.cs · Cited by 195 · see citing works
Changes in the glycemic profiles of women with type 1 and type 2 diabetes during pregnancy
Murphy, H. R., Rayman, G., Duffield, K., Lewis, K. S., Kelly, S., Johal, B., Fowler, D., & Temple, R. C. (2007) · Diabetes Care · doi:10.2337/dc07-0500 · Cited by 138 · see citing works
Bhansali, S., Dutta, P., Kumar, V., Yadav, M. K., Jain, A., Mudaliar, S., Bhansali, S., Sharma, R. R., Jha, V., Marwaha, N., et al. (2017) · Stem Cells and Development · doi:10.1089/scd.2016.0275 · Cited by 126 · see citing works
Daily negative mood affects fasting glucose in type 2 diabetes
Skaff, M. M., Mullan, J. T., Almeida, D. M., Hoffman, L., Masharani, U., Mohr, D., & Fisher, L. (2009) · Health Psychology · doi:10.1037/a0014429 · Cited by 72 · see citing works
Association of glucose levels and glucose variability with mood in type 1 diabetic patients
Hermanns, N., Scheff, C., Kulzer, B., Weyers, P., Pauli, P., Kubiak, T., & Haak, T. (2007) · Diabetologia · doi:10.1007/s00125-007-0643-y · Cited by 66 · see citing works
Noninvasive Hypoglycemia Detection in People With Diabetes Using Smartwatch Data
Lehmann, V., Föll, S., Maritsch, M., van Weenen, E., Kraus, M., Lagger, S., Odermatt, K., Albrecht, C., Fleisch, E., Zueger, T., et al. (2023) · Diabetes Care · doi:10.2337/dc22-2290 · Cited by 47 · see citing works
Klonoff, D. C., Gabbay, M., Moon, S. J., & Wilmot, E. G. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241250357 · Cited by 36 · see citing works
Chan, A., Heinemann, L., Anderson, S. M., Breton, M. D., & Kovatchev, B. P. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400416 · Cited by 13 · see citing works
- Authors
- Bode, B. W., Schwartz, S., Stubbs, H. A., & Block, J. E.
- Affiliations
- Atlanta Diabetes Associates (US)
- Diabetes & Glandular Disease Clinic (US)
- Oakland, California
- San Francisco, California
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2005-10-01
- Volume
- 28
- Issue
- 10
- Pages
- 2361-2366
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2095240021
- Cited by
- 137
- References
- 39
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 5 · 2022: 3 · 2021: 7 · 2020: 5 · 2019: 6 · 2018: 6 · 2017: 6 · 2016: 4 · 2015: 8 · 2014: 4 · 2013: 7 · 2012: 4
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Diabetes Care (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- type 1 diabetes, type 2 diabetes, continuous glucose monitoring, glycemic excursions, hypoglycemia, hyperglycemia, normoglycemia, reference values, time in range, nocturnal hypoglycemia, glycemic variability
- MeSH terms
- Adult, Circadian Rhythm, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Female, Humans, Hyperglycemia, Hypoglycemia, Male, Middle Aged, Monitoring, Physiologic, Obesity, Prospective Studies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review