Cited by 43Renal function and acid-base balanceNeonatal and fetal brain pathologyPregnancy and preeclampsia studies

How to assess fetal metabolic acidosis front cord samples

Rosén, Karl G., Murphy, Karl W.·1991·jpme

Abstract

The degree of metabolic acidosis at birth has been calculated in cord artery and vein samples from 21 term fetuses with cord artery pH less than 7.20. The aim of the study was to compare base deficit values calculated from either Siggaard-Andersen alignment nomogram (BD blood) or the Acid-Base chart (BD extra cellular fluid, BDecf). BDblood was found to be consistently higher in the cord artery as compared with BDecf, 13.2 +/- 3.5 and 9.9 +/- 2.9 mmol/l (Mean +/- SD), respectively. A significant correlation was found between cord artery PCO2 and BDblood whereas BDecf appeared unaffected by PCO2. In cases with cord entanglement BDecf a-v differences were increased to 3.4 +/- 2.3 mmol/l as compared with the small a-v difference noted in acidotic cases without cord entanglement, 1.1 +/- 1.25 mmol/l. It is speculated that with acutely emerging, intermittent asphyxia due to cord compression, a cord artery and vein difference in metabolic acidosis may exist and where the vein captures the basal level and the artery the acute changes. It is concluded that BDecf in both cord artery and vein add valuable information on the mechanisms behind metabolic acidosis.

Integrity signals

Registry

Crossref · 10.1515/jpme.1991.19.3.221

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Base deficit in extracellular fluid is advocated for fetal blood because high partial pressure of CO2 is common in newborns without concomitant hypoxia, and hypercapnia has a strong influence on pH.

    “Base deficit in extracellular fluid is advocated for fetal blood because a high partial pressure of CO 2 (hypercapnia) is common in newborns without concomitant hypoxia, and hypercapnia has a strong influence on the pH value, then termed respiratory acidosis.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Rosén, K. G., & Murphy, K. W.
Affiliations
University of Gothenburg (SE)
Venue
jpme
Published
1991
Volume
19
Issue
3
Pages
221-226
ISSN
  • 0300-5577 (ISSN-L)
  • 1619-3997
OpenAlex
W2041835480
Cited by
43
References
13
Citations by year
2023: 1 · 2021: 1 · 2019: 1 · 2018: 1 · 2016: 3 · 2014: 1 · 2013: 1 · 2012: 3
FWCI
1.70
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Perinatal Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Nephrology › Renal function and acid-base balance
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Neonatal and fetal brain pathology
  • Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
Keywords
umbilical cord blood, base deficit, arteriovenous differences, cord compression, fetal asphyxia, fetal acid-base status
MeSH terms
Acidosis, Lactic, Carbon Dioxide, Fetal Blood, Humans, Hydrogen-Ion Concentration, Infant, Newborn, Umbilical Arteries, Umbilical Veins

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review