Detection of metal ions in biological systems: A review
Open accessThe DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.
Abstract
Metal ions are widely present in biological systems and participate in many critical biochemical processes such as material transportation, energy conversion, information transmission and metabolic regulation, making them indispensable substance in our body. They can cause health problems when deficiency or excess occurs. To understand various metabolic processes and facilitate diseases diagnosis, it is very important to measure the content and monitor the distribution of metal ions in individual cells, tissues and whole organisms. Among the various methods for metal ion detection, fluorescent sensors with organic dyes have attracted tremendous attention due to many advantages such as high fluorescence quantum yield, facile modification approaches and biocompatibility in addition to operation ease, high sensitivity, fast detection speed, and real-time detection. This review summarizes the recent progress on the detection and imaging of the metal ions in biological systems including Na + , K + , Ca 2+ , Mg 2+ , Fe 2+ /Fe 3+ , Zn 2+ , and Cu 2+ provides an opinion on remaining challenges to be addressed in this field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The biochemical basis of zinc physiology
Vallee, B. L., & Falchuk, K. H. (1993) · Physiological Reviews · doi:10.1152/physrev.1993.73.1.79 · Cited by 2,990 · cited 1×
“Zinc is the only metal ion that appears in all six enzyme classes and over 300 enzymes [92] and 1000 transcription factors require zinc for their function [93].”
BackgroundFluorescent Sensors for Measuring Metal Ions in Living Systems
Carter, K. P., Young, A. M., & Palmer, A. E. (2014) · Chemical Reviews · doi:10.1021/cr400546e · Cited by 2,451 · cited 1×
“As the major metal ions in our body fluid, alkali metals ions, Na+ and K+ are responsible for maintenance of fluid and electrolyte balance, acid-base homeostasis, and maintenance of cell membrane potential allowing the generation of action potentials that are critical for neurotransmission, muscle contraction, and hea…”
BackgroundInfluentialFluorescent Probes for Sensing and Imaging within Specific Cellular Organelles
Zhu, H., Fan, J., Du, J., & Peng, X. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00292 · Cited by 984
Zhang, J. F., Zhou, Y., Yoon, J., & Kim, J. S. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15028f · Cited by 826 · cited 1×
“In the past decades, several spectrophotometric methods and electroanalytical techniques for metal ions detection have been developed, such as atomic absorption/ emission spectroscopy [11,12], inductively coupled plasma mass spectroscopy (ICP-MS) [13,14], electrochemical assays [15,16], and colorimetric methods [17,18…”
MethodSelf-citationDiscerning the Chemistry in Individual Organelles with Small‐Molecule Fluorescent Probes
Xu, W., Zeng, Z., Jiang, J., Chang, Y., & Yuan, L. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201510721 · Cited by 808 · cited 1×
“[28] Xu W, Zeng Z, Jiang J, Chang Y, Yuan L.”
BackgroundHouk, R. S., Fassel, V. A., Flesch, G. D., Svec, H. J., Gray, A. L., & Taylor, C. E. (1980) · Analytical Chemistry · doi:10.1021/ac50064a012 · Cited by 766 · cited 2×
“[13] Houk RS, Fassel VA, Flesch GD, Svec HJ.”
BackgroundMethodFluorescent probes for organelle-targeted bioactive species imaging
Gao, P., Pan, W., Li, N., & Tang, B. (2019) · Chemical Science · doi:10.1039/c9sc01652j · Cited by 599
Ghaedi, M., Ahmadi, F., & Shokrollahi, A. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2006.08.012 · Cited by 598 · cited 2×
“[11] Ghaedi M, Ahmadi F, Shokrollahi A.”
MethodLü, B., Chen, Y., Li, P., Wang, B., Müllen, K., & Yin, M. (2019) · Nature Communications · doi:10.1038/s41467-019-08434-4 · Cited by 454 · cited 2×
“Fluorescent probes have become versatile tools due to their promising photophysical properties including high sensitivity and selectivity, low detection limit, fast response, operational simplicity, realtime monitoring and low cost [19,20].”
BackgroundSelf-citationStern, B. R. (2010) · Journal of Toxicology and Environmental Health, Part A · doi:10.1080/15287390903337100 · Cited by 453 · cited 1×
“Copper also stimulates the immune system to fight infections, to repair injured tissues, and to promote healing [107].”
Background
Metadata
- Authors
- Zheng, X., Cheng, W., Ji, C., Zhang, J., & Yin, M.
- Venue
- Reviews in Analytical Chemistry
- Publisher
- Walter de Gruyter GmbH
- Published
- 2020-01-01
- Volume
- 39
- Issue
- 1
- Pages
- 231-246
- ISSN
- 0793-0135 (ISSN-L)
- 2191-0189
- OpenAlex
- W3127701518
- Cited by
- 180
- References
- 87
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of metal ions in biological systems: A review. https://app.cochat.ai/papers/10.1515/revac-2020-0118
- The paper
- Zheng, X., Cheng, W., Ji, C., Zhang, J., & Yin, M. (2020). Detection of metal ions in biological systems: A review. Reviews in Analytical Chemistry. https://doi.org/10.1515/revac-2020-0118
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.