The DOI matches its Crossref record.
Die pCO2-/pO2-Optode: Eine neue p CO2- bzw. pO2-Meßsonde zur Messung des pCO2 oder pO2 von Gasen und Flüssigkeiten / The pCO2-/pO2-Optode: A New Probe for Measurement of pCO2 or pO2 in Fluids and Gases
Open accessAbstract
To measure pO 2 or pCO 2 in gases or fluids the fluorescence indicators pyrene butyric acid or β-methylumbelli-feron were used, which were separated from a measuring medium by a gas-permeable membrane. For p CO 2 the pH changes in NaHCO 3 solution were monitored by methyl-umbelliferon. Changes in its fluorescence signal, S, were measured at λ (emission) = 445 nm. Excitation was brought about by light of wavelength λ 1 = 318 nm (fluorescence signal S 1) , and λ 2 = 357 nm (fluorescence signal S 2). Drawing lg(S 2/S 1) against lg(pCO 2-1), one obtains a straight line between a p CO 2 of 10 and 70 Torr. The response time is about 3 to 4 s (90%). For pO 2 , pyrene butyric acid is used (λ (excitation) = 342 nm; λ(emission) = 395 nm). A linear increase in pO 2 between 0 and 300 Torr yields a linear increase in the reciprocal fluorescence signal. The response time is about 3 s (90%).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bühlmann, P., Pretsch, E., & Bakker, E. (1998) · Chemical Reviews · doi:10.1021/cr970113+ · Cited by 1,859
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Materials for fluorescence-based optical chemical sensors
Wolfbeis, O. S. (2005) · Journal of Materials Chemistry · doi:10.1039/b501536g · Cited by 486
Nanomaterials-based biosensor and their applications: A review
Malik, S., Singh, J., Goyat, R., Saharan, Y., Chaudhry, V., Umar, A., Ibrahim, A. A., Akbar, S., Ameen, S., & Baskoutas, S. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e19929 · Cited by 441
Metadata
- Authors
- Lübbers, D. W., & Opitz, N.
- Venue
- Zeitschrift für Naturforschung C
- Publisher
- Walter de Gruyter GmbH
- Published
- 1975-08-01
- Volume
- 30
- Issue
- 7-8
- Pages
- 532-533
- ISSN
- 0341-0471 (ISSN-L)
- 1865-7125
- 0939-5075
- OpenAlex
- W4324263027
- Cited by
- 165
- References
- 0
- FWCI
- 1.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Die pCO2-/pO2-Optode: Eine neue p CO2- bzw. pO2-Meßsonde zur Messung des pCO2 oder pO2 von Gasen und Flüssigkeiten / The pCO2-/pO2-Optode: A New Probe for Measurement of pCO2 or pO2 in Fluids and Gases. https://app.cochat.ai/papers/10.1515/znc-1975-7-819
- The paper
- Lübbers, D. W., & Opitz, N. (1975). Die pCO2-/pO2-Optode: Eine neue p CO2- bzw. pO2-Meßsonde zur Messung des pCO2 oder pO2 von Gasen und Flüssigkeiten / The pCO2-/pO2-Optode: A New Probe for Measurement of pCO2 or pO2 in Fluids and Gases. Zeitschrift für Naturforschung C. https://doi.org/10.1515/znc-1975-7-819
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.