Biodegradable vs non-biodegradable antibiotic delivery devices in the treatment of osteomyelitis
The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Chronic osteomyelitis, or bone infection, is a major worldwide cause of morbidity and mortality, as it is exceptionally hard to treat due to patient and pathogen-associated factors. Successful treatment requires surgical debridement together with long-term, high antibiotic concentrations that are best achieved by local delivery devices, either made of degradable or non-degradable materials. AREAS COVERED: Non-degradable delivery devices are frequently constituted by polymethylmethacrylate-based carriers. Drawbacks are the need to remove the carrier (as the carrier itself may provide a substratum for bacterial colonization), inefficient release kinetics and incompatibility with certain antibiotics. These drawbacks have led to the quest for degradable alternatives, but also devices made of biodegradable calcium sulphate, collagen sponges, calcium phosphate or polylactic acids have their specific disadvantages. EXPERT OPINION: Antibiotic treatment of osteomyelitis with the current degradable and non-degradable delivery devices is effective in the majority of cases. Degradable carriers have an advantage over non-degradable carriers that they do not require surgical removal. Synthetic poly(trimethylene carbonate) may be preferred in the future over currently approved lactic/glycolic acids, because it does not yield acidic degradation products. Moreover, degradable poly(trimethylene carbonate) yields a zero-order release kinetics that may not stimulate development of antibiotic-resistant bacterial strains due to the absence of long-term, low-concentration tail-release.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
RETRACTED: Bone graft substitutes: What are the options?
Dinopoulos, H., Dimitriou, R. I., & Giannoudis, P. V. (2012) · The Surgeon · doi:10.1016/j.surge.2012.04.001 · Cited by 87 · cited 1×
“Autologous bone grafting is however limited and associated with serious drawbacks, for instance due to the requirement of an additional surgical donor site [69].”
BackgroundRetractedCosterton, J. W., Lewandowski, Z., Caldwell, D. E., Korber, D. R., & Lappin-Scott, H. M. (1995) · Annual Review of Microbiology · doi:10.1146/annurev.mi.49.100195.003431 · Cited by 4,544
The global burden of diabetic foot disease
Boulton, A. J., Vileikyte, L., Ragnarson-Tennvall, G., & Apelqvist, J. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67698-2 · Cited by 2,566 · cited 1×
“Although efforts have been undertaken to reduce the incidence and consequences of osteomyelitis, a large proportion of the world population still suffers from chronic osteomyelitis, primarily because of a vast increase in reconstructive orthopaedic procedures [4] and higher prevalence of diabetes mellitus [5], combine…”
BackgroundBiomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206 · cited 3×
“While PDLLA takes over a year to degrade, most antibiotics are released by diffusion through the matrix, making PDLLA unsuitable for drug release applications outside coatings or tissue engineering scaffolds [98].”
BackgroundMethodInfluentialMechanisms of antibiotic resistance in bacterial biofilms
Stewart, P. S. (2002) · International Journal of Medical Microbiology · doi:10.1078/1438-4221-00196 · Cited by 1,385 · cited 2×
“These protective mechanisms appear to be distinct from those responsible for conventional antibiotic resistance [7], making biofilm organisms up to 800-fold less susceptible to antibiotics than planktonic ones [8].”
BackgroundMathematical modeling of bioerodible, polymeric drug delivery systems
Siepmann, J. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00116-8 · Cited by 772
Management of deep infection of total hip replacement
Buchholz, H., Elson, R., Engelbrecht, E., Lodenkamper, H., Rottger, J., & Siegel, A. (1981) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.63b3.7021561 · Cited by 706 · cited 3×
“Antibiotics such as ampicillin, cefoxitin, cephazolin, clindamycin and streptomycin have also been successfully incorporated and released from PMMA [23,40,45,47].”
BackgroundMethodAntibiotic-eluting medical devices for various applications
ZILBERMAN, M., & ELSNER, J. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.05.020 · Cited by 610 · cited 2×
“Collagen has been studied most extensively because of relative biocompatibility, low costs and easy availability [65], and has been commercially available for over 20 years.”
BackgroundOsteomyelitis: The Past Decade
Waldvogel, F. A., & Vasey, H. (1980) · New England Journal of Medicine · doi:10.1056/nejm198008143030703 · Cited by 568 · cited 1×
“In case of biofilm-associated infections, many clinicians prefer using the term “remission” rather than “cure” after apparent bacterial eradication, because actual persistence is frequent, resulting in long-term recurrence rates of approximately 20 -- 30% [9-13].”
BackgroundForeign-body reactions to fracture fixation implants of biodegradable synthetic polymers
Bostman, O., Hirvensalo, E., Makinen, J., & Rokkanen, P. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b4.2199452 · Cited by 526 · cited 2×
“Among the polylactic/polyglycolic acid carriers, the co-polymer PLGA shows the best release characteristics determined by bulk erosion, but all carriers are known to produce acidic degradation products that can lead to bone resorption [95-97].”
Background
Cited by
A Review of Biodegradable Natural Polymer-Based Nanoparticles for Drug Delivery Applications
Idrees, H., Zaidi, S. Z. J., Sabir, A., Khan, R. U., Zhang, X., & Hassan, S.-U. (2020) · Nanomaterials · doi:10.3390/nano10101970 · Cited by 419
Nanoparticle-based local antimicrobial drug delivery
Gao, W., Chen, Y., Zhang, Y., Zhang, Q., & Zhang, L. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.09.015 · Cited by 396
Biofilms in Periprosthetic Orthopedic Infections
McConoughey, S. J., Howlin, R., Granger, J. F., Manring, M. M., Calhoun, J. H., Shirtliff, M., Kathju, S., & Stoodley, P. (2014) · Future Microbiology · doi:10.2217/fmb.14.64 · Cited by 343
Antifouling and antimicrobial biomaterials: an overview
Francolini, I., Vuotto, C., Piozzi, A., & Donelli, G. (2017) · APMIS · doi:10.1111/apm.12675 · Cited by 322
Li, Y., Liu, L., Wan, P., Zhai, Z., Mao, Z., Ouyang, Z., Yu, D., Sun, Q., Tan, L., Ren, L., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.08.031 · Cited by 286
Combating Implant Infections: Shifting Focus from Bacteria to Host
Amin Yavari, S., Castenmiller, S. M., van Strijp, J. A. G., & Croes, M. (2020) · Advanced Materials · doi:10.1002/adma.202002962 · Cited by 257
Mesoporous bioactive glasses: Promising platforms for antibacterial strategies
Kargozar, S., Montazerian, M., Hamzehlou, S., Kim, H.-W., & Baino, F. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.09.052 · Cited by 252
van Vugt, T. A. G., Arts, J. J., & Geurts, J. A. P. (2019) · Frontiers in Microbiology · doi:10.3389/fmicb.2019.01626 · Cited by 239
“Examples of these materials are natural polymers like collagen and chitosan; synthetic polymers like polylactide; ceramics like calcium sulfates and calcium phosphates (hydroxyapatite and tricalcium phosphate) and bioactive glasses (El-Husseiny et al., 2011; Kluin et al., 2013).”
Background
Metadata
- Authors
- Kluin, O. S., van der Mei, H. C., Busscher, H. J., & Neut, D.
- Venue
- Expert Opinion on Drug Delivery
- Publisher
- Informa UK Limited
- Published
- 2013-01-06
- Volume
- 10
- Issue
- 3
- Pages
- 341-351
- ISSN
- 1742-5247 (ISSN-L)
- 1744-7593
- OpenAlex
- W2121388120
- Cited by
- 171
- References
- 80
- FWCI
- 14.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.