The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Thermosensitive chitosan/glycerophosphate-based hydrogel and its derivatives in pharmaceutical and biomedical applications
Abstract
INTRODUCTION: Thermogelling chitosan (CS)/glycerophosphate (GP) solutions have been reported as a new type of parenteral in situ forming depot system. These free-flowing solutions at ambient temperature turn into semi-solid hydrogels after parenteral administration. AREAS COVERED: Formulation parameters such as CS physico-chemical characteristics, CS/gelling agent ratio or pH of the system, were acknowledged as key parameters affecting the solution stability, the sol/gel transition behavior and/or the final hydrogel structure. We discuss also the use of the standard CS/GP thermogels for various biomedical applications, including drug delivery and tissue engineering. Furthermore, this manuscript reviews the different strategies implemented to improve the hydrogel characteristics such as combination with carrier particles, replacement of GP, addition of a second polymer and chemical modification of CS. EXPERT OPINION: The recent advances in the formulation of CS-based thermogelling systems already overcame several challenges faced by the standard CS/GP system. Dispersion of drug-loaded carrier particles into the thermogels allowed achieving prolonged release profiles for low molecular weight drugs; incorporation of an additional polymer enabled to strengthen the network, while the use of chemically modified CS led to enhanced pH sensitivity or biodegradability of the matrix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
Cited by
Chitosan: an update on potential biomedical and pharmaceutical applications.
Cheung, R., Ng, T., Wong, J., & Chan, W. (2015) · Marine Drugs · doi:10.3390/md13085156 · Cited by 1,297
Stability of Chitosan—A Challenge for Pharmaceutical and Biomedical Applications
Szymańska, E., & Winnicka, K. (2015) · Marine Drugs · doi:10.3390/md13041819 · Cited by 942
Thermoresponsive hydrogels in biomedical applications
Klouda, L. (2015) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2015.05.017 · Cited by 491
Glycerophosphate-based chitosan thermosensitive hydrogels and their biomedical applications
Zhou, H. Y., Jiang, L. J., Cao, P. P., Li, J. B., & Chen, X. G. (2015) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2014.09.094 · Cited by 397
The biological applications of DNA nanomaterials: current challenges and future directions
Ma, W., Zhan, Y., Zhang, Y., Mao, C., Xie, X., & Lin, Y. (2021) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-021-00727-9 · Cited by 331
Metadata
- Authors
- Supper, S., Anton, N., Seidel, N., Riemenschnitter, M., Curdy, C., & Vandamme, T.
- Venue
- Expert Opinion on Drug Delivery
- Publisher
- Informa Healthcare
- Published
- 2013-12-05
- Volume
- 11
- Issue
- 2
- Pages
- 249-267
- ISSN
- 1742-5247 (ISSN-L)
- 1744-7593
- OpenAlex
- W2142634248
- Cited by
- 164
- References
- 1
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermosensitive chitosan/glycerophosphate-based hydrogel and its derivatives in pharmaceutical and biomedical applications. https://app.cochat.ai/papers/10.1517/17425247.2014.867326
- The paper
- Supper, S., Anton, N., Seidel, N., Riemenschnitter, M., Curdy, C., & Vandamme, T. (2014). Thermosensitive chitosan/glycerophosphate-based hydrogel and its derivatives in pharmaceutical and biomedical applications. Expert Opinion on Drug Delivery. https://doi.org/10.1517/17425247.2014.867326
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.