Evaluation of the stress generation on the cortical bone and the palatal micro-implant complex during the implant-supported en masse retraction in lingual orthodontic technique using the FEM: Original research
Open accessAbstract
Background. This study aimed to evaluate and analyze the distribution of stresses on the palatal micro-implants and the cortical bone at the micro-implant site with optimal orthodontic retraction force in lingual orthodontics. Methods. ANSYS 12.1 software was used to construct the finite element model of the maxillary bone, teeth and the periodontal ligament along with the lingual bracket set-up with wire and the micro-implant. Six- and 8-mm micro-implants were constructed. The final model consisted of 99190 nodes and 324364 elements. A 200-gram of retraction force was applied from the micro-implant to the anterior retraction hook. The micro-implant was embedded between the second premolar and the first molar. Hyper-view software was used to get the results in X-Y-Z dimensions. Results. The maximum von Mises stresses detected were 52.543 MPa for 6-mm micro-implant and 54.489 MPa for 8-mm micro-implant. Maximum stress was at the neck of the micro-implant. The 8-mm implant model showed 6×10-3 mm of lingual displacement. The least displacement of 1×10-3 mm was noticed for both the implant models in the apico-occlusal direction. The maximum von Mises stresses in the cortical bone at the micro-implant site was 18.875 MPa for 6-mm micro-implant and 21.551 MPa for 8-mm micro-implant. Conclusion. Six-mm micro-implant can be the choice for the implant-supported lingual orthodontic retraction as it produced minimal stresses on the cortical bone, and the initial stress displacements produced on the micro-implant were also minimal.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The attributes of linear, homogeneous, continuous, isotropic materials and a semicontrolled mesh with high-order tetrahedral elements are commonly used in biomodelling and numerical analysis on biological tissues and organs.
“All these attributes are commonly used when performing biomodelling and numerical analysis on biological tissues and organs [22, 37, 43–50].”
From Numerical Analysis of the ACL, with Sprains of Different Degrees after Trauma (2021) · cites this paper as [50]
The Discussion (page unavailable) says that, as in previous finite-element studies, the authors modeled cortical bone as isotropic, homogeneous, and linearly elastic. The Methods (page unavailable) describe four-noded tetrahedral elements, not the claimed high-order elements, and do not identify the mesh as semicontrolled. The paper does not establish that all these attributes are commonly used across biological tissues and organs. (LLM, conf=0.85)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Miyawaki, S., Koyama, I., Inoue, M., et al. (2003) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(03)00565-1 · Cited by 889 · see citing works
Moon, C., Lee, D., Lee, H.-S., et al. (2007) · The Angle Orthodontist · doi:10.2319/121706-515.1 · Cited by 232 · see citing works
Titanium alloy mini-implants for orthodontic anchorage: Immediate loading and metal ion release
de Morais, L. S., Serra, G., Müller, C., et al. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2006.10.010 · Cited by 182 · see citing works
Anatomical guidelines for miniscrew insertion: palatal sites.
Ludwig, B., Glasl, B., Bowman, S. J., et al. (2011) · PubMed · Cited by 160 · see citing works
Determination of the centre of resistance in an upper human canine and idealized tooth model
Vollmer, D. (1999) · European Journal of Orthodontics · doi:10.1093/ejo/21.6.633 · Cited by 140 · see citing works
Sivamurthy, G., & Sundari, S. (2016) · Progress in Orthodontics · doi:10.1186/s40510-016-0117-1 · Cited by 116 · see citing works
Jasmine, M. I. F., Yezdani, A. A., Tajir, F., et al. (2011) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2011.06.031 · Cited by 100 · see citing works
Finite element analysis of miniscrew implants used for orthodontic anchorage
Liu, T.-C., Chang, C.-H., Wong, T.-Y., et al. (2012) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2011.11.012 · Cited by 97 · see citing works
Reimann, S., Keilig, L., Jäger, A., et al. (2007) · European Journal of Orthodontics · doi:10.1093/ejo/cjl086 · Cited by 95 · see citing works
Wang, Y., & Liou, E. J. (2008) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2006.01.042 · Cited by 76 · see citing works
Loss of anchorage of miniscrews: A 3-dimensional assessment
El-Beialy, A. R., Abouelezz, A. M., Attia, K. H., et al. (2009) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2007.10.059 · Cited by 69 · see citing works
Singh, S., Mogra, S., Shetty, V. S., et al. (2012) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2011.07.022 · Cited by 69 · see citing works
Effect of mini-implant diameter on fracture risk and self-drilling efficacy
Barros, S. E., Janson, G., Chiqueto, K., et al. (2011) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2011.06.016 · Cited by 63 · see citing works
Effect of miniscrew angulation on anchorage resistance
Woodall, N., Tadepalli, S. C., Qian, F., et al. (2011) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2010.08.017 · Cited by 54 · see citing works
Load transfer of miniscrews for orthodontic anchorage
Dalstra, M., Cattaneo, P., & Melsen, B. (2004) · Cited by 49 · see citing works
Optimal Palatal Configuration for Miniscrew Applications
Lombardo, L., Gracco, A. L. T., Zampini, F., et al. (2009) · The Angle Orthodontist · doi:10.2319/122908-662.1 · Cited by 46 · see citing works
Lee, J., Kim, J. Y., Choi, Y. J., et al. (2012) · The Angle Orthodontist · doi:10.2319/090112-703.1 · Cited by 43 · see citing works
Three-dimensional numerical simulation of dental implants as orthodontic anchorage
Gallas, M. (2005) · European Journal of Orthodontics · doi:10.1093/ejo/cjh066 · Cited by 43 · see citing works
Zhao, L., Xu, Z., Wei, X. C., et al. (2011) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2009.06.040 · Cited by 34 · see citing works
Chen, Y., Kang, S. T., Bae, S.-M., et al. (2009) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2007.10.046 · Cited by 32 · see citing works
Stress on bone from placement and removal of orthodontic miniscrews at different angulations.
Noble, J., Karaiskos, N. E., Hassard, T. H., et al. (2009) · PubMed · Cited by 18 · see citing works
Machado, G. L. (2014) · The Saudi Journal for Dental Research · doi:10.1016/j.sjdr.2014.01.001 · Cited by 17 · see citing works
Effects of washer on the stress distribution of mini-implant
Jang, H.-J., Kwon, S.-Y., Kim, S., et al. (2011) · The Angle Orthodontist · doi:10.2319/021411-107.1 · Cited by 15 · see citing works
Zhang, Y., Zhang, D., Feng, C., et al. (2006) · Journal of Hard Tissue Biology · doi:10.2485/jhtb.15.69 · Cited by 14 · see citing works
Effect of intrusive and retraction forces in labial and lingual orthodontics: A finite element study
Mascarenhas, R., Mathew, J., Revankar, A. V., et al. (2014) · APOS Trends in Orthodontics · doi:10.4103/2321-1407.127745 · Cited by 12 · see citing works
Clinical effects associated with miniscrews used as orthodontic anchorage
Kokitsawat, S., Manosudprasit, M., Godfrey, K., et al. (2008) · Australasian Orthodontic Journal · doi:10.2478/aoj-2008-0020 · Cited by 9 · see citing works
Lee, N., Choi, D., Jang, I., et al. (2008) · The Korean Journal of Orthodontics · doi:10.4041/kjod.2008.38.5.304 · Cited by 9 · see citing works
The Use of Microimplants in Lingual Orthodontic Treatment
Kyung, H. (2006) · Seminars in Orthodontics · doi:10.1053/j.sodo.2006.05.006 · Cited by 6 · see citing works
Zhang, Y., Zhang, D., & Feng, C. (2005) · PubMed · Cited by 5 · see citing works
Digital lingual orthodontics and temporary anchorage devices for efficient biomechanics
Shetty, P. S., & Khan, W. (2016) · The Journal of Indian Orthodontic Society · doi:10.4103/0301-5742.198632 · Cited by 1 · see citing works
Frost (2004) · doi:10.1043/0003-3219(2004)074
Flagged first, then by citations
Cited by
Sorted by citations
Numerical Analysis of the ACL, with Sprains of Different Degrees after Trauma
Marquet-Rivera, R. A., Urriolagoitia-Sosa, G., Romero-Ángeles, B., Hernández-Vázquez, R. A., Mastache-Miranda, O. A., Cruz-López, S., Torres-Yáñez, A., & Urriolagoitia-Calderón, G. (2021) · Computational and Mathematical Methods in Medicine · doi:10.1155/2021/2109348 · Cited by 5 · see citing works
Hernández-Vázquez, R. A., Marquet-Rivera, R. A., Mastache-Miranda, O. A., Vázquez-López, A. J., Cruz-López, S., & Vázquez-Feijoo, J. A. (2021) · Applied Bionics and Biomechanics · doi:10.1155/2021/6658039 · Cited by 4 · see citing works
- Authors
- Shyagali, T. R., & Aghera, D.
- Affiliations
- Professor and Head, Department of Orthodontics and Dentofacial Orthopedics, Hitkarini Dental College and Hospital, Jabalpur, India
- Private practitioner, Rajkot, India
- Corresponding author
- Aghera, Dhaval
- Venue
- Journal of Dental Research Dental Clinics Dental Prospects
- Publisher
- Maad Rayan Publishing Company
- Published
- 2019-12-05
- Volume
- 13
- Issue
- 3
- Pages
- 192-199
- ISSN
- 2008-210X (ISSN-L)
- 2008-2118
- PMC
- PMC6904918
- OpenAlex
- W2982901670
- Cited by
- 4
- References
- 32
- Citations by year
- 2021: 3 · 2020: 1
- FWCI
- 1.17
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- cc-by
- Locations
- Journal of Dental Research Dental Clinics Dental Prospects (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Dentistry › Orthodontics › Orthodontics and Dentofacial Orthopedics
- Health Sciences › Dentistry › Orthodontics › Dental materials and restorations
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › dental development and anomalies
- Keywords
- en-masse retraction, cortical bone stress, von Mises stress, maxillary bone, periodontal ligament, finite element model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review