Validity of HydraTrend Reagent Strips for the Assessment of Hydration Status
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Hydration is used by athletic governing organizations for weight class eligibility. The measurement of urine specific gravity (USG) as a measure of hydration by reagent strips is a controversial issue. The purpose of this study was to determine the validity of HydraTrend reagent strips that facilitate the correction of USG for alkaline urine samples against refractometry for the assessment of USG. Fifty-one participants (33 males, age = 22.3 ± 1.3 years; 18 females, age = 22.4 ± 1.2 years) provided 84 urine samples. The samples were tested for USG using refractometry and reagent strips and for pH using reagent strips and a digital pH meter. Strong correlation coefficients were found between refractometry and reagent strips for USG (rs(82) = 0.812, p 1.020, pass reagent strips with USG ≤1.020) occurred 39% (33/84) of the time and false negative results for National Federation of State High School Association (NFHS) requirements (fail refractometry with USG >1.025, pass reagent strips with USG ≤1.025) occurred 14% (12/84) of the time. There were no false positives (pass refractometry and fail reagent strips) for NCAA or NFHS requirements. These data show that refractometry and reagent strips have strong positive correlations. However, the risk of a false negative result leading to incorrect certification of euhydration status outweighs the benefits of the HydraTrend reagent strips for the measurement of USG.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Urine reagent strips are unreliable, even when manufactured solely for hydration assessment, 245 and are not recommended for this purpose.”
From National Athletic Trainers' Association Position Statement: Fluid Replacement for the Physically Active (2017) · cites this paper as [245]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Urinary Indices of Hydration Status
Armstrong, L. E., Maresh, C. M., Castellani, J. W., Bergeron, M. F., Kenefick, R. W., LaGasse, K. E., & Riebe, D. (1994) · International Journal of Sport Nutrition · doi:10.1123/ijsn.4.3.265 · Cited by 548
Blood and urinary measures of hydration status during progressive acute dehydration
POPOWSKI, L. A., OPPLIGER, R. A., PATRICK LAMBERT, G., JOHNSON, R. F., KIM JOHNSON, A., & GISOLFI, C. V. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200105000-00011 · Cited by 345
Urinary Indices during Dehydration, Exercise, and Rehydration
Armstrong, L. E., Herrera Soto, J. A., Hacker, F. T., Casa, D. J., Kavouras, S. A., & Maresh, C. M. (1998) · International Journal of Sport Nutrition · doi:10.1123/ijsn.8.4.345 · Cited by 306
Hydration Assessment Techniques
Armstrong, L. E. (2005) · Nutrition Reviews · doi:10.1111/j.1753-4887.2005.tb00153.x · Cited by 292
Accuracy of urine specific gravity and osmolality as indicators of hydration status
Oppliger, R. A., Magnes, S. A., Popowski, L. A., & Gisolfi, C. V. (2005) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.15.3.236 · Cited by 175
Utter, A. C., McAnulty, S. R., Riha, B. F., Pratt, B. A., & Grose, J. M. (2012) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e318238ea51 · Cited by 26
Dipstick measurements of urine specific gravity are unreliable
Roessingh, A. D. B., Drukker, A., & Jp, G. (2001) · Archives of Disease in Childhood · doi:10.1136/adc.85.2.155
Evaluation of Ames Multistix-SG for Urine Specific Gravity versus Refractometer Specific Gravity
Adams, L. J. (1983) · American Journal of Clinical Pathology · doi:10.1093/ajcp/80.6.871
Research works printed but not linked: 7
- 1998, Hyperthermia and dehydration-related deaths associated with intentional rapid weight loss in three collegiate wrestlers-North Carolina, Wisconsin, and Michigan, November-December 1997., JAMA, 279, 824
- Guthrie, 1987, Does the dipstick meet medical needs for urine specific gravity J Fam P, ract, 25, 512
- Ito, 1983, Study of urinary specific gravity by reagent strip method., Tokai J Exp Clin Med, 8, 247
- McCrossin, 1985, Comparison of hydrometry, refractometry, osmometry and Ames N-Multistix SG in estimation of urinary concentration., Aust Paediatr J, 21, 185
- Stuempfle, 2003, Comparison of 3 methods to assess urine specific gravity in collegiate wrestlers., J Athl Train, 38, 315
- Utter, 2001, The new National Collegiate Athletic Association wrestling weight certification program and sport-seasonal changes in body composition of college wrestlers., J Strength Cond Res, 15, 296
- Utter, 2007, The NFHS wrestling weight management program., High Sch Today, 1, 20
Cited by
McDermott, B. P., Anderson, S. A., Armstrong, L. E., Casa, D. J., Cheuvront, S. N., Cooper, L., Kenney, W. L., O'Connor, F. G., & Roberts, W. O. (2017) · Journal of Athletic Training · doi:10.4085/1062-6050-52.9.02 · Cited by 438
“Urine reagent strips are unreliable, even when manufactured solely for hydration assessment, 245 and are not recommended for this purpose.”
Metadata
- Authors
- Abbey, B. M., Heelan, K. A., Brown, G. A., & Bartee, R. T.
- Venue
- Journal of Strength and Conditioning Research
- Published
- 2014-09
- Volume
- 28
- Issue
- 9
- Pages
- 2634-2639
- ISSN
- 1064-8011
- Cited by
- 12
- References
- 14
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity of HydraTrend Reagent Strips for the Assessment of Hydration Status. https://app.cochat.ai/papers/10.1519/jsc.0000000000000430
- The paper
- Abbey, B. M., Heelan, K. A., Brown, G. A., & Bartee, R. T. (2014). Validity of HydraTrend Reagent Strips for the Assessment of Hydration Status. Journal of Strength and Conditioning Research. https://doi.org/10.1519/jsc.0000000000000430
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.