Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716–725, 2018—Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time–frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O 2 above 60%).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Improvements in heart rate variability with exercise therapy
Routledge, F. S., Campbell, T. S., McFetridge-Durdle, J. A., & Bacon, S. L. (2010) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(10)70395-0 · Cited by 381
Possibilities and limitations of the polar RS800 in measuring heart rate variability at rest
Wallén, M. B., Hasson, D., Theorell, T., Canlon, B., & Osika, W. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2079-9 · Cited by 135
Cited by
Goldsack, J. C., Coravos, A., Bakker, J. P., Bent, B., Dowling, A. V., Fitzer-Attas, C., Godfrey, A., Godino, J. G., Gujar, N., Izmailova, E., et al. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0260-4 · Cited by 557
Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review
Georgiou, K., Larentzakis, A. V., Khamis, N. N., Alsuhaibani, G. I., Alaska, Y. A., & Giallafos, E. J. (2018) · Folia Medica · doi:10.2478/folmed-2018-0012 · Cited by 244
Hernando, D., Roca, S., Sancho, J., Alesanco, Á., & Bailón, R. (2018) · Sensors · doi:10.3390/s18082619 · Cited by 222
“Several works in the literature have already validated, using as reference the RR interval series derived from a synchronous ECG, the RR interval series given by different models of Polar devices: S810 [35,36], RS800 [37,38], and V800 with a H7 chest belt [22,23].”
MethodSelf-citationDobbs, W. C., Fedewa, M. V., MacDonald, H. V., Holmes, C. J., Cicone, Z. S., Plews, D. J., & Esco, M. R. (2019) · Sports Medicine · doi:10.1007/s40279-019-01061-5 · Cited by 189
Is emotion regulation associated with cancer-related psychological symptoms?
Guimond, A.-J., Ivers, H., & Savard, J. (2019) · Psychology & Health · doi:10.1080/08870446.2018.1514462 · Cited by 51
Metadata
- Authors
- Hernando, D., Garatachea, N., Almeida, R., Casajús, J. A., & Bailón, R.
- Venue
- Journal of Strength and Conditioning Research
- Published
- 2018-03
- Volume
- 32
- Issue
- 3
- Pages
- 716-725
- ISSN
- 1064-8011 (ISSN-L)
- OpenAlex
- W2528848028
- Cited by
- 138
- References
- 5
- FWCI
- 6.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise. https://app.cochat.ai/papers/10.1519/jsc.0000000000001662
- The paper
- Hernando, D., Garatachea, N., Almeida, R., Casajús, J. A., & Bailón, R. (2018). Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise. Journal of Strength and Conditioning Research. https://doi.org/10.1519/jsc.0000000000001662
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.