Neural Drive is Greater for a High-Intensity Contraction Than for Moderate-Intensity Contractions Performed to Fatigue
The DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index.
Abstract
Miller, JD, Lippman, JD, Trevino, MA, and Herda, TJ. Larger motor units are recruited for high-intensity contractions than for fatiguing moderate-intensity contractions. J Strength Cond Res 34(11): 3013–3021, 2020—The purpose of this study was to investigate whether moderate-intensity contractions performed to fatigue activate the motor unit (MU) pool to the same extent as a higher-intensity contraction. Subjects (7 men, 2 women, age = 22.78 ± 4.15 years, height = 173.78 ± 14.19 cm, mass = 87.39 ± 21.19 kg) performed 3 isometric maximum voluntary contractions (MVCs), an isometric trapezoidal contraction at 90% MVC (REP 90 ), and repetitive isometric trapezoidal contractions at 50% MVC performed to failure with the first (REP 1 ) and final repetition (REP L ) used for analysis. Surface EMG was recorded from the vastus lateralis. Action potentials were extracted into firing events of single MUs with recruitment thresholds (RTs), MU action potential amplitudes (MUAP AMP ), and mean firing rates (MFRs) recorded. Linear MFR and MUAP AMP vs. RT and exponential MFR vs. MUAP AMP relationships were calculated for each subject. The level of significance was set at p ≤ 0.05. B terms for the MFR vs. MUAP AMP relationships ( p = 0.001, REP L = −4.77 ± 1.82 pps·mV −1 , REP 90 = −2.63 ± 1.00 pps·mV −1 ) and predicted MFRs for MUs recruited at 40% MVC ( p < 0.001, REP L = 11.14 ± 3.48 pps, REP 90 = 18.38 ± 2.60 pps) were greater for REP 90 than REP L indicating firing rates were greater during REP 90 . In addition, larger mean ( p = 0.038, REP L = 0.178 ± 0.0668 mV, REP 90 = 0.263 ± 0.128 mV) and maximum ( p = 0.008, REP L = 0.320 ± 0.127 mV, Rep 90 = 0.520 ± 0.234 mV) MUAP AMPS were recorded during REP 90 than REP L . Larger MUs were recruited and similar sized MUs maintained greater firing rates during a high-intensity contraction in comparison to a moderate-intensity contraction performed at fatigue. Individuals seeking maximized activation of the MU pool should use high-intensity resistance training paradigms rather than moderate-intensity to fatigue.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“studies have advocated in favor of either high loads (12–15) or both low and high loads (16) to achieve maximal or near-maximal recruitment of motor units during fatiguing contractions to induce muscle hypertrophy.”
From Resistance training load effects on muscle hypertrophy and strength gain: systematic review and network meta-analysis. (2021) · cites this paper as [15]
Citations
Cites
Fundamentals of Resistance Training: Progression and Exercise Prescription
KRAEMER, W. J., & RATAMESS, N. A. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000121945.36635.61 · Cited by 2,722
Physiological types and histochemical profiles in motor units of the cat gastrocnemius
Burke, R. E., Levine, D. N., Tsairis, P., & Zajac, F. E. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010369 · Cited by 1,565 · cited 1×
“primarily composed of Type II fibers (2,3).”
The orderly recruitment of human motor units during voluntary isometric contractions
Milner‐Brown, H. S., Stein, R. B., & Yemm, R. (1973) · The Journal of Physiology · doi:10.1113/jphysiol.1973.sp010192 · Cited by 920 · cited 2×
“increasing isometric muscle actions (17,26).”
BackgroundSchoenfeld, B. J., Grgic, J., Ogborn, D., & Krieger, J. W. (2017) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000002200 · Cited by 851 · cited 3×
“However, most EMG studies report greater muscle activation (20,22,30,35) for highintensity contractions and the majority of resistance training studies report greater strength gains from high-load programs (27,28,36,37).”
BackgroundRELATIONS BETWEEN STRUCTURE AND FUNCTION IN THE DESIGN OF SKELETAL MUSCLES
Henneman, E., & Olson, C. B. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.3.581 · Cited by 763 · cited 1×
“principle (15), and action potential amplitudes are correlatedwith”
BackgroundSupraspinal factors in human muscle fatigue: evidence for suboptimal output from the motor cortex.
Gandevia, S. C., Allen, G. M., Butler, J. E., & Taylor, J. L. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021164 · Cited by 681 · cited 2×
“(13) investigated voluntary activation via interpolated twitch over the time course of sustained isometricMVCs of the elbow flexors and reported high initial voluntary activation (.”
BackgroundResistance exercise load does not determine training-mediated hypertrophic gains in young men
Mitchell, C. J., Churchward-Venne, T. A., West, D. W. D., Burd, N. A., Breen, L., Baker, S. K., & Phillips, S. M. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00307.2012 · Cited by 627 · cited 4×
“However, most EMG studies report greater muscle activation (20,22,30,35) for highintensity contractions and the majority of resistance training studies report greater strength gains from high-load programs (27,28,36,37).”
BackgroundResultInfluentialThe Role of Resistance Exercise Intensity on Muscle Fibre Adaptations
Fry, A. C. (2004) · Sports Medicine · doi:10.2165/00007256-200434100-00004 · Cited by 626 · cited 1×
“load resistance training paradigms is of high research interest (12,36).”
BackgroundThe extraction of neural strategies from the surface EMG: an update
Farina, D., Merletti, R., & Enoka, R. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00162.2014 · Cited by 589 · cited 1×
“It is possible to observe seemingly valid MU action potential waveforms from trigger events that do not correspondwithMUdischarges (9).”
BackgroundBottinelli, R., Canepari, M., Pellegrino, M. A., & Reggiani, C. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021617 · Cited by 565 · cited 1×
“primarily composed of Type II fibers (2,3).”
Cited by
LOPEZ, P., RADAELLI, R., TAAFFE, D. R., NEWTON, R. U., GALVÃO, D. A., TRAJANO, G. S., TEODORO, J. L., KRAEMER, W. J., HÄKKINEN, K., & PINTO, R. S. (2021) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002585 · Cited by 340
“, motor units are recruited from smallest to largest) (11), studies have advocated in favour of either high loads (12-15) or both low and high loads (16) to achieve maximal or near-maximal recruitment of motor units during fatiguing contractions to induce muscle hypertrophy.”
BackgroundStone, M. H., Hornsby, W. G., Haff, G. G., Fry, A. C., Suarez, D. G., Liu, J., González‐Ravé, J. M., & Pierce, K. C. (2021) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000004050 · Cited by 173
Training Specificity for Athletes: Emphasis on Strength-Power Training: A Narrative Review
Stone, M. H., Hornsby, W. G., Suarez, D. G., Duca, M., & Pierce, K. C. (2022) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk7040102 · Cited by 142
Hooren, B. V., Aagaard, P., & Blazevich, A. J. (2024) · Sports Medicine · doi:10.1007/s40279-024-02110-4 · Cited by 58
“…will be better recruited (and thus trained) as the lower threshold motor units fatigue [334], neural drive and motor unit recruitment have been found to be reduced during moderate-load fatiguing repetitions compared to using high-load repetitions in some [335], although not all, studies [336].”
Resistance exercise training and the motor unit
Herda, T. J. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04983-7 · Cited by 33
“Furthermore, the largest MUs with the greatest twitch forces for the VL were likely not recruited during the 50% MVC as modeled (De Luca and Kline 2012) and previous work would suggest (Muddle et al. 2018; Miller et al. 2020).”
ResultSelf-citationPoncin, W., Willemsens, A., Gely, L., & Contal, O. (2024) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.11074 · Cited by 24
“55,56 Another important limitation is related to the sample sizes in each study, which were globally relatively small.”
Kinetic and kinematic profile of eccentric quasi-isometric loading
Oranchuk, D. J., Diewald, S. N., McGrath, J. W., Nelson, A. R., Storey, A. G., & Cronin, J. B. (2021) · Sports Biomechanics · doi:10.1080/14763141.2021.1890198 · Cited by 20
“Of note, it is unlikely that moderate-intensity contractions taken to failure, synonymous with EQIs, would be as effective as briefer, high-intensity contractions for improving motor unit activation (Miller et al., 2020).”
BackgroundResultInglis, J. G., Cabral, H. V., Cosentino, C., Bonardi, A., & Negro, F. (2025) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00863.2024 · Cited by 19
Keller, J. L., Housh, T. J., Anders, J. P. V., Neltner, T. J., Schmidt, R. J., & Johnson, G. O. (2021) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04588-y · Cited by 19
Intentionally Slow Concentric Velocity Resistance Exercise and Strength Adaptations: A Meta-Analysis
Hermes, M. J., & Fry, A. C. (2023) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000004490 · Cited by 18
“Recently, it has been shown that higher-intensity contractions recruit larger motor units and maintained greater motor unit firing rates than a lower-intensity contraction performed to failure (43).”
BackgroundTrevino, M. A., Dimmick, H. L., Parra, M. E., Sterczala, A. J., Miller, J. D., Deckert, J. A., Gallagher, P. M., Fry, A. C., Weir, J. P., & Herda, T. J. (2022) · Experimental Brain Research · doi:10.1007/s00221-021-06278-3 · Cited by 17
“Therefore, it is speculated that the loss of type IIX % myosin heavy chain isoform in the present study would support the notion that these fibers exist in smaller to moderate size MUs as the magnitude of input excitation would not recruit the highest threshold MUs during a contraction at 40% MVC (Miller et al. 2020)…”
BackgroundSelf-citationHarmon, K. K., Hamilton, A. S., Johnson, B. D., Bartek, F. J., Girts, R. M., MacLennan, R. J., Hahs‐Vaughn, D. L., & Stock, M. S. (2021) · European Journal of Applied Physiology · doi:10.1007/s00421-021-04606-7 · Cited by 13
Okudaira, M., Hirono, T., Takeda, R., Nishikawa, T., Ueda, S., Mita, Y., Holobar, A., Yoshimura, A., & Watanabe, K. (2023) · Experimental Brain Research · doi:10.1007/s00221-023-06590-0 · Cited by 12
“Neural adaptation caused by resistance training has been widely assessed using intramuscular and surface EMG (Kamen and Knight 2004; Kidgell et al. 2006; Pucci et al. 2006; Vila-Cha et al. 2010; Miller et al. 2020; Sterczala et al. 2020; MacLennan et al. 2022), but those results have yet to facilitate a reasonable con…”
BackgroundNishikawa, T., Takeda, R., Ueda, S., Igawa, K., Hirono, T., Okudaira, M., Mita, Y., Ohya, T., & Watanabe, K. (2025) · European Journal of Nutrition · doi:10.1007/s00394-025-03634-9 · Cited by 10
“Increasing training intensity leads to the activation of MUs with a higher recruitment threshold [11].”
Low-Level Laser Therapy Facilitates Postcontraction Recovery with Ischemic Preconditioning
Chen, Y.-C., LIN, Y.-T., Hu, C., & Hwang, I. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003149 · Cited by 10
Beausejour, J. P., Knowles, K. S., Pagan, J. I., Rodriguez, J. P., Sheldon, D., Ruple, B. A., Plotkin, D. L., Smith, M. A., Godwin, J. S., Sexton, C. L., et al. (2024) · PeerJ · doi:10.7717/peerj.18163 · Cited by 10
“…; Pethick & Tallent, 2022 ). sEMG excitation responses to the fatiguing task were also not different between training groups and con fi rm previously reported characteristics of sEMG excitation during isometric, fatiguing protocols ( Harmon et al., 2021 ; Miller et al., 2020 ; Muddle et al., 2018 ).”
BackgroundEstimating Exercise-Induced Changes in Human Neuronal Networks
Türker, K. S. (2021) · Exercise and Sport Sciences Reviews · doi:10.1249/jes.0000000000000255 · Cited by 7
Davis, B. H., Spielmann, G., Johannsen, N. M., Fairchild, V., Allerton, T. D., & Irving, B. A. (2025) · Physiological Reports · doi:10.14814/phy2.70274 · Cited by 6
Reece, T. M., Arnold, C. E., & Herda, T. J. (2021) · Experimental Physiology · doi:10.1113/ep089808 · Cited by 6
Self-citationDimmick, H. L., Trevino, M. A., Miller, J. D., Parra, M. E., Sterczala, A. J., & Herda, T. J. (2022) · PubMed Central · Cited by 6
Self-citationVelocity-Specific Adaptations to Three Widely Used Strength Training Methods
Trane, G., PEDERSEN, S., Mehus, H. A., Helgerud, J., & Unhjem, R. (2024) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003630 · Cited by 5
Nishikawa, T., Hirono, T., Takeda, R., Okudaira, M., Ohya, T., & Watanabe, K. (2023) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2023-0208 · Cited by 5
Herda, T. J., Holmes, E. A., Cleary, C. J., Minor, K. T., Thyfault, J. P., Shook, R. P., & Herda, A. A. (2024) · European Journal of Applied Physiology · doi:10.1007/s00421-024-05455-w · Cited by 6
“For most circumstances, increases in MU firing rates coincides with recruitment of inactive MUs (Miller et al. 2020).”
Self-citationNishikawa, T., Hirono, T., Takeda, R., Okudaira, M., Ohya, T., & Watanabe, K. (2024) · Physiology & Behavior · doi:10.1016/j.physbeh.2024.114585 · Cited by 5
Olmos, A. A., Sontag, S. A., Lawson, D. J., Richardson, L. D., Roth, B. L., Jeon, S., SMITH, J., Redinger, A. L., & Trevino, M. A. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-025-05849-4 · Cited by 4
“With repetitive muscle actions to failure, it suggested that greater neural drive be necessary, resulting in increasing firing rates of active MUs and recruitment of additional higher threshold MUs to modulate torque (Gandevia 2001; Contessa et al. 2016; Muddle et al. 2018; Miller et al. 2020).”
Self-citationInvestigation into the neuromuscular mechanisms of resistance priming
Pratt, J. (2023) · Queensland University of Technology · doi:10.5204/thesis.eprints.238335 · Cited by 4
Assessment of Muscle Fatigue Using EMG under Long Duration and High Intensity Fatigue Condition
Nam, D., & Park, K. (2022) · Journal of the Korean Society for Precision Engineering · doi:10.7736/jkspe.022.020 · Cited by 2
LeMense, A. T., Fleming, A. R., Gomez, S. A., Lewis, J., Labanowski, H., Fedewa, M. V., & Winchester, L. J. (2025) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.70006 · Cited by 1
“…with some non ‐ BFR research indicating that high load and high velocity resistance exercise already recruits high threshold motor units (Miller et al., 2020; Sakamoto & Sinclair, 2012), whereas some BFR research that has indicated that increased metabolic stress may cause inhibition of…”
Butts, R., England, B., Siekirk, N. J., Masters, M. F., & Flannigan, S. (2025) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2025.08.034 · Cited by 1
Utility of Back-Off Sets: An Overview
Rodriguez, J., Hanney, W. J., Kolber, M. J., & Cheatham, S. W. (2021) · Strength and conditioning journal · doi:10.1519/ssc.0000000000000623 · Cited by 1
Kuniki, M., Iwamoto, Y., Konishi, R., Kuwahara, D., Yamagiwa, D., & Kito, N. (2023) · Research Square · doi:10.21203/rs.3.rs-2800466/v1 · Cited by 1
Pennartz, K. J., Smith, C. D., Washington, S. M., Gebert, R., Wolfe, A., Keller, J. L., & Luera, M. J. (2025) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000005231
Swann, C. C. (2025) · Memorial University Research Repository (Memorial University) · doi:10.48336/zha2-6006
Procena brzine neuromišićnog odgovora – optimizacija testa i ispitivanje njegove osetljivosti
Stefanović, Ž. (2024) · National Repository of Dissertations in Serbia
高齢者の筋力トレーニングにおける運動単位活動特性の特徴とケルセチンの摂取が与える影響
Nishikawa, T. (2025) · Institutional Repositories DataBase (IRDB)
Nanto, T., Nakao, Y., Eimoto, K., Oshima, Y., One, S., Maeda, R., Aizawa, S., Suetsugi, Y., & Ono, T. (2026) · Journal of Oral Rehabilitation · doi:10.1111/joor.70243
High-Intensity Exercise Performance as a Complex Adaptive System: An Integrative Review
Alkasasbeh, W. J., Amawi, A. T., & Grivas, G. V. (2026) · Muscles · doi:10.3390/muscles5030053 · Cited by 1
“The interaction between neural drive, spinal modulation, and muscular function determines the overall capacity to sustain performance under high-intensity conditions [148].”
Takeda, R., Hirono, T., Nishikawa, T., Ueda, S., Igawa, K., Uchida, K., Mita, Y., & Watanabe, K. (2026) · Physiology International · doi:10.1556/2060.2026.00836
Trane, G., Rodahl, S. E., Gomo, O. M., Mehus, H. A., Helgerud, J., & Unhjem, R. (2026) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000005694
Yağcı, S. (2025) · Dspace Repository (Marmara Üniversitesi)
Metadata
- Authors
- Miller, J. D., Lippman, J. D., Trevino, M. A., & Herda, T. J.
- Affiliations
- University of Kansas (US)
- Neuromechanics Laboratory, Department of Health, Sport and Exercise Sciences, University of Kansas, Lawrence, Kansas; and
- Oklahoma State University (US)
- Corresponding author
- Herda, Trent J.
- Venue
- Journal of Strength and Conditioning Research
- Published
- 2020-08-31
- Volume
- 34
- Issue
- 11
- Pages
- 3013-3021
- ISSN
- 1064-8011 (ISSN-L)
- OpenAlex
- W3081573604
- Cited by
- 34
- References
- 41
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 6 · 2023: 6 · 2022: 5 · 2021: 7 · 2020: 1
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Journal of Strength and Conditioning Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- motor unit recruitment, motor unit firing rate, motor unit action potential amplitude, muscle fatigue, isometric contraction, vastus lateralis, recruitment threshold, surface electromyography, neuromuscular fatigue
- MeSH terms
- Action Potentials, Adult, Electromyography, Female, Humans, Isometric Contraction, Male, Recruitment, Neurophysiological, Muscle Fatigue, Quadriceps Muscle, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.