The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Performance of A3MCNP™ for Calculation of 3-D Neutron Flux Distribution in a BWR Core Shroud
Abstract
This paper analyzes the performance of the A3MCNP™ (Automated Adjoint Accelerated MCNP) for determination of neutron fluence in a BWR core shroud. A3MCNP™ automatically prepares variance reduction parameters based on the CADIS (Consistent Adjoint Driven Importance Sampling) methodology that uses a 3-D energy dependent “importance” function. A3MCNP™ prepares necessary input files for performing adjoint transport calculations using the TORT Sn code. Using A3MCNP™, we have calculated DPA (displacement per atom) values (with a lσ uncertainty) at the H4 weld of a BWR core shroud in less than 5 CPU hour. For the same calculation, an analog Monte Carlo simulation requires about one month of CPU time. The trade-off between the accuracy of the adjoint function calculation and overall computation cost is examined. It is demonstrated that even for a very approximate adjoint function distribution, A3MCNP™ yields significant speedup over an analog Monte Carlo calculation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kalos, M. H., & Whitlock, P. A. (1986) · Wiley eBooks · doi:10.1002/9783527617395 · Cited by 1,546
Computational methods of neutron transport
Williams, M. M. R. (1985) · Annals of Nuclear Energy · doi:10.1016/0306-4549(85)90125-2 · Cited by 839
Kalos, M. H. (1963) · Nuclear Science and Engineering · doi:10.13182/nse63-a26504 · Cited by 41
Cited by
An overview and analysis of site remediation technologies
Khan, F. I., Husain, T., & Hejazi, R. (2004) · Journal of Environmental Management · doi:10.1016/j.jenvman.2004.02.003 · Cited by 957
Caplin, M. E., Baudin, E., Ferolla, P., Filosso, P., Garcia-Yuste, M., Lim, E., Oberg, K., Pelosi, G., Perren, A., Rossi, R. E., et al. (2015) · Annals of Oncology · doi:10.1093/annonc/mdv041 · Cited by 714
SPECIAL ARTICLE: Cognitive, Social and Environmental Sources of Bias in Clinical Performance Ratings
Williams, R. G., Klamen, D. A., & McGaghie, W. C. (2003) · Teaching and Learning in Medicine · doi:10.1207/s15328015tlm1504_11 · Cited by 391
Errare machinale est: the use of error-related potentials in brain-machine interfaces
Chavarriaga, R., Sobolewski, A., & Millán, J. D. R. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00208 · Cited by 311
Malaria rapid diagnostic tests: challenges and prospects
Mouatcho, J. C., & Goldring, J. P. D. (2013) · Journal of Medical Microbiology · doi:10.1099/jmm.0.052506-0 · Cited by 291
Metadata
- Authors
- Haghighat, A., Hiruta, H., & Petrovic, B.
- Venue
- Reactor Dosimetry: Radiation Metrology and Assessment
- Published
- 2001-01-01
- Pages
- 549-556
- OpenAlex
- W1775600962
- Cited by
- 255
- References
- 3
- FWCI
- 35.23
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.