Accurate Localization of Linear Probe Electrode Arrays across Multiple Brains
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Recently developed probes for extracellular electrophysiological recordings have large numbers of electrodes on long linear shanks. Linear electrode arrays, such as Neuropixels probes, have hundreds of recording electrodes distributed over linear shanks that span several millimeters. Because of the length of the probes, linear probe recordings in rodents usually cover multiple brain areas. Typical studies collate recordings across several recording sessions and animals. Neurons recorded in different sessions and animals thus have to be aligned to each other and to a standardized brain coordinate system. Here, we evaluate two typical workflows for localization of individual electrodes in standardized coordinates. These workflows rely on imaging brains with fluorescent probe tracks and warping 3D image stacks to standardized brain atlases. One workflow is based on tissue clearing and selective plane illumination microscopy (SPIM), whereas the other workflow is based on serial block-face two-photon (SBF2P) microscopy. In both cases electrophysiological features are then used to anchor particular electrodes along the reconstructed tracks to specific locations in the brain atlas and therefore to specific brain structures. We performed groundtruth experiments, in which motor cortex outputs are labeled with ChR2 and a fluorescence protein. Light-evoked electrical activity and fluorescence can be independently localized. Recordings from brain regions targeted by the motor cortex reveal better than 0.1-mm accuracy for electrode localization, independent of workflow used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796
Receptive fields of single neurones in the cat's striate cortex
Hubel, D. H., & Wiesel, T. N. (1959) · The Journal of Physiology · doi:10.1113/jphysiol.1959.sp006308 · Cited by 4,653
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225 · cited 7×
“Second, we cross-validated the electrophysiological landmark at the surface of the brain (i.e., an increase in LFP power inside the brain) by analyzing other electrophysiological signatures beneath the brain surface.”
BackgroundInfluentialA mesoscale connectome of the mouse brain
Oh, S. W., Harris, J. A., Ng, L., Winslow, B., Cain, N., Mihalas, S., Wang, Q., Lau, C., Kuan, L., Henry, A. M., et al. (2014) · Nature · doi:10.1038/nature13186 · Cited by 2,612 · cited 5×
“…et al., 2012; Economo et al., 2016), which relies on relatively expensive and customized instrumentation, but produces images that are easily aligned to a widely used standardized brain coordinate system (common coordinate framework; CCF v3; Lein et al., 2007; Oh et al., 2014; Wang et al., 2020).”
BackgroundMethodInfluentialFully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Self-citationLarge-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875
Neuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings.
Steinmetz, N. A., Aydin, C., Lebedeva, A., Okun, M., Pachitariu, M., Bauza, M., Beau, M., Bhagat, J., Böhm, C., Broux, M., et al. (2021) · Science · doi:10.1126/science.abf4588 · Cited by 1,173 · cited 2×
“Neuropixels probes (Jun et al., 2017; Steinmetz et al., 2021) provide recordings across 960 recording electrodes distributed over 9.6 mm shanks.”
BackgroundInfluentialSelf-citationThe subcellular organization of neocortical excitatory connections
Petreanu, L., Mao, T., Sternson, S. M., & Svoboda, K. (2009) · Nature · doi:10.1038/nature07709 · Cited by 1,047 · cited 2×
“8, 9), 100 nl of AAV2/5-CamKII-hChR2-EYFP-WPRE virus (4.6 1012 titer; UNC) was injected into ALM (2.5 mm anterior, 1.5 mm lateral, 0.8 mm from the dura surface) of C57BL/6J mice (n=7; dx.doi.org/10.17504/protocols.io.bctxiwpn) in the same surgery with headbar implantation (Petreanu et al., 2009).”
BackgroundMethodSelf-citationHierarchical organization of cortical and thalamic connectivity
Harris, J. A., Mihalas, S., Hirokawa, K. E., Whitesell, J. D., Choi, H., Bernard, A., Bohn, P., Caldejon, S., Casal, L., Cho, A., et al. (2019) · Nature · doi:10.1038/s41586-019-1716-z · Cited by 785
Cited by
Neuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings.
Steinmetz, N. A., Aydin, C., Lebedeva, A., Okun, M., Pachitariu, M., Bauza, M., Beau, M., Bhagat, J., Böhm, C., Broux, M., et al. (2021) · Science · doi:10.1126/science.abf4588 · Cited by 1,173
Self-citationCortico-thalamo-cortical interactions modulate electrically evoked EEG responses in mice
Claar, L. D., Rembado, I., Kuyat, J. R., Russo, S., Marks, L. C., Olsen, S. R., & Koch, C. (2023) · eLife · doi:10.7554/elife.84630.3 · Cited by 36
“1 mm accuracy for electrode localization following similar methods (Liu et al., 2021).”
Method
Metadata
- Authors
- Liu, L. D., Chen, S., Hou, H., West, S. J., Faulkner, M., Laboratory, T. I. B., Economo, M. N., Li, N., & Svoboda, K.
- Venue
- eneuro
- Publisher
- Society for Neuroscience
- Published
- 2021-10-25
- Volume
- 8
- Issue
- 6
- Pages
- ENEURO.0241-21.2021
- ISSN
- 2373-2822 (ISSN-L)
- OpenAlex
- W3210323664
- Cited by
- 59
- References
- 22
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accurate Localization of Linear Probe Electrode Arrays across Multiple Brains. https://app.cochat.ai/papers/10.1523/eneuro.0241-21.2021
- The paper
- Liu, L. D., Chen, S., Hou, H., West, S. J., Faulkner, M., Laboratory, T. I. B., Economo, M. N., Li, N., & Svoboda, K. (2021). Accurate Localization of Linear Probe Electrode Arrays across Multiple Brains. eneuro. https://doi.org/10.1523/eneuro.0241-21.2021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.