Human Microsaccade-Related Visual Brain Responses
Open accessThe DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Abstract
Microsaccades are very small, involuntary flicks in eye position that occur on average once or twice per second during attempted visual fixation. Microsaccades give rise to EMG eye muscle spikes that can distort the spectrum of the scalp EEG and mimic increases in gamma band power. Here we demonstrate that microsaccades are also accompanied by genuine and sizeable cortical activity, manifested in the EEG. In three experiments, high-resolution eye movements were corecorded with the EEG: during sustained fixation of checkerboard and face stimuli and in a standard visual oddball task that required the counting of target stimuli. Results show that microsaccades as small as 0.15° generate a field potential over occipital cortex and midcentral scalp sites 100–140 ms after movement onset, which resembles the visual lambda response evoked by larger voluntary saccades. This challenges the standard assumption of human brain imaging studies that saccade-related brain activity is precluded by fixation, even when fully complied with. Instead, additional cortical potentials from microsaccades were present in 86% of the oddball task trials and of similar amplitude as the visual response to stimulus onset. Furthermore, microsaccade probability varied systematically according to the proportion of target stimuli in the oddball task, causing modulations of late stimulus-locked event-related potential (ERP) components. Microsaccades present an unrecognized source of visual brain signal that is of interest for vision research and may have influenced the data of many ERP and neuroimaging studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“4c– e) using the erpimage function of the EEGLAB toolbox (Delorme and Makeig, 2004) for MATLAB (The MathWorks).”
MethodOscillatory gamma activity in humans and its role in object representation
Tallon-Baudry, C. (1999) · Trends in Cognitive Sciences · doi:10.1016/s1364-6613(99)01299-1 · Cited by 2,129
Dynamic Brain Sources of Visual Evoked Responses
Makeig, S., Westerfield, M., Jung, T.-P., Enghoff, S., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2002) · Science · doi:10.1126/science.1066168 · Cited by 1,630
Microsaccades uncover the orientation of covert attention
Engbert, R., & Kliegl, R. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00084-1 · Cited by 1,390 · cited 8×
“Microsaccades are not only correlated with visual awareness, but also with visuospatial attention (Hafed and Clark, 2002; Kohama and Usui, 2002; Engbert and Kliegl, 2003; Laubrock et al., 2005), and their rate is influenced by higher-level”
BackgroundMethodResultInfluentialSelf-citationThe role of fixational eye movements in visual perception
Martinez-Conde, S., Macknik, S. L., & Hubel, D. H. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1348 · Cited by 1,255 · cited 2×
“The most prominent contribution to FEMs is generated by microsaccades, small (a few arcmin to 1.0°), high-velocity flicks in eye position that are embedded into slower drifting movements at an average rate of 1–2 per second (Martinez-Conde et al., 2004).”
BackgroundResultInfluentialOn Quantifying Surprise: The Variation of Event‐Related Potentials With Subjective Probability
Duncan‐Johnson, C. C., & Donchin, E. (1977) · Psychophysiology · doi:10.1111/j.1469-8986.1977.tb01312.x · Cited by 1,224 · cited 1×
“Both target status (target or nontarget) and stimulus frequency are known to modulate the amplitude of the P300 component of the ERP in oddball tasks (Duncan-Johnson and Donchin, 1977).”
BackgroundThe Freiburg Visual Acuity Test???Automatic Measurement of Visual Acuity
Bach, M. (1996) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1996.tb04409.x · Cited by 984
Transient induced gamma-band response in EEG as a manifestation of miniature saccades
Yuval-Greenberg, S., Tomer, O., Keren, A. S., Nelken, I., & Deouell, L. Y. (2008) · Neuron · doi:10.1016/j.neuron.2008.03.027 · Cited by 776
Attention modulates responses in the human lateral geniculate nucleus
O'Connor, D. H., Fukui, M. M., Pinsk, M. A., & Kastner, S. (2002) · Nature Neuroscience · doi:10.1038/nn957 · Cited by 734
The brainstem control of saccadic eye movements
Sparks, D. L. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn986 · Cited by 717 · cited 2×
“Figure 2b (left) discussed (Nativ et al., 1990; Parks and Corballis, 2008), it is generally thought to originate in the extraocular muscles and to reflect a summation of EMG spikes during the maximal recruitment of motor units at saccade onset (Moster and Goldberg, 1990; Sparks, 2002).”
Background
Cited by
Coregistration of eye movements and EEG in natural reading: Analyses and review.
Dimigen, O., Sommer, W., Hohlfeld, A., Jacobs, A. M., & Kliegl, R. (2011) · Journal of Experimental Psychology: General · doi:10.1037/a0023885 · Cited by 602
Self-citationMicrosaccades: Small steps on a long way
Rolfs, M. (2009) · Vision Research · doi:10.1016/j.visres.2009.08.010 · Cited by 521
The impact of microsaccades on vision: towards a unified theory of saccadic function
Martinez-Conde, S., Otero-Millan, J., & Macknik, S. L. (2013) · Nature Reviews Neuroscience · doi:10.1038/nrn3405 · Cited by 461
Thaler, L., Schütz, A. C., Goodale, M. A., & Gegenfurtner, K. R. (2013) · Vision Research · doi:10.1016/j.visres.2012.10.012 · Cited by 419
Propofol Anesthesia and Sleep: A High-Density EEG Study
Murphy, M., Bruno, M.-A., Riedner, B. A., Boveroux, P., Noirhomme, Q., Landsness, E. C., Brichant, J.-F., Phillips, C., Massimini, M., Laureys, S., et al. (2011) · Sleep · doi:10.1093/sleep/34.3.283 · Cited by 418
Plöchl, M., Ossandón, J. P., & König, P. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00278 · Cited by 372
Eye Movement and Pupil Measures: A Review
Mahanama, B., Jayawardana, Y., Rengarajan, S., Jayawardena, G., Chukoskie, L., Snider, J., & Jayarathna, S. (2022) · Frontiers in Computer Science · doi:10.3389/fcomp.2021.733531 · Cited by 307
Occipital gamma activation during Vipassana meditation
Cahn, B. R., Delorme, A., & Polich, J. (2010) · Cognitive Processing · doi:10.1007/s10339-009-0352-1 · Cited by 300
“…activity artifact from eye movements have been correlated with saccades (Reva and Aftanas 2004; Yuval-Greenberg and Deouell 2009) and microsaccades (Dimigen et al. 2009; Yuval-Greenberg et al. 2008) and that the present subjects were recorded in an eyeclosed state, the probability of eye movements…”
Saccadic spike potentials in gamma-band EEG: Characterization, detection and suppression
Keren, A. S., Yuval-Greenberg, S., & Deouell, L. Y. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.057 · Cited by 263
Optimizing the ICA-based removal of ocular EEG artifacts from free viewing experiments
Dimigen, O. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116117 · Cited by 222
“…have received attention because even involuntary microsaccades ( < 1 (cid:1) ) during attempted fi xation generate sizeable SPs (Armington, 1978; Dimigen et al., 2009; Yamazaki, 1968; Yuval-Green-berg et al., 2008), which introduce a broadband artifact in the time-frequency spectrum of the EEG,…”
Self-citationSzczepanski, S. M., Crone, N. E., Kuperman, R. A., Auguste, K. I., Parvizi, J., & Knight, R. T. (2014) · PLoS Biology · doi:10.1371/journal.pbio.1001936 · Cited by 179
“We think this case is unlikely, since microsaccades induce bilateral cortical effects [57], while many of the electrodes exhibited strongly lateralized increases in delta/theta-HG PAC.”
BackgroundEhinger, B. V., & Dimigen, O. (2019) · PeerJ · doi:10.7717/peerj.7838 · Cited by 178
“However, with this function, unfold can also be used as a standalone toolbox for Mass-Univariate modeling, for the (rare) cases in which an experiment does not involve any overlapping activity (e.g., from small saccades; Dimigen et al., 2009).”
InfluentialSelf-citationOuyang, G., Sommer, W., & Zhou, C. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.10.009 · Cited by 161
Self-citationThe saccadic spike artifact in MEG
Carl, C., Açık, A., König, P., Engel, A. K., & Hipp, J. F. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.020 · Cited by 110
“…spike artifact based on patient data and sensor characteristics of the saccadic spike (Becker et al., 1972; Blinn, 1955; Boylan and Doig, 1989b; Dimigen et al., 2009; Keren et al., 2010a; Moster and Goldberg, 1990; Picton et al., 2000; Riemslag et al., 1988; Thickbroom and Mastaglia, 1985,…”
Microsaccades Are Coupled to Heartbeat
Ohl, S., Wohltat, C., Kliegl, R., Pollatos, O., & Engbert, R. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.2211-15.2016 · Cited by 75
“Because microsaccades evoke gamma-band activity in the EEG (YuvalGreenberg et al., 2008; Dimigen et al., 2009), our results on the coupling of microsaccades and heartbeat indicate the need for recording FEM and ECG to reduce systematic influences of ocular artifacts on electrophysiological signals…”
BackgroundSelf-citation
Metadata
- Authors
- Dimigen, O., Valsecchi, M., Sommer, W., & Kliegl, R.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 2009-09-30
- Volume
- 29
- Issue
- 39
- Pages
- 12321-12331
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W2066009488
- Cited by
- 176
- References
- 67
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.