The DOI matches its OpenAlex record; 7 of the 7 references it cites were found in a registry or an index.
The Freiburg Visual Acuity Test???Automatic Measurement of Visual Acuity
Abstract
The Freiburg Visual Acuity test is an automated procedure for self-administered measurement of visual acuity. Landolt-Cs are presented on a monitor in one of eight orientations. The subject presses one of eight buttons, which are spatially arranged on a response box according to the eight possible positions of the Landolt-Cs' gap. To estimate the acuity threshold, a best PEST (best Parameter Estimation by Sequential Testing) procedure is used in which a psychometric function having a constant slope on a logarithmic acuity scale is assumed. Measurement terminates after a fixed number of trials. With computer monitors, pixel-discreteness artifacts limit the presentation of small stimuli. By using anti-aliasing, i.e., smoothing of contours by multiple gray levels, the spatial resolution was improved by a factor of four. Thus, even the shape of small Landolt-Cs with oblique gaps is adequate and visual acuities from 5/80 (0.06) up to 5/1.4 (3.6) can be tested at a distance of 5 m.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1966) · Medical Entomology and Zoology · Cited by 10,293
Collett, D. (1991) · Springer eBooks · doi:10.1007/978-1-4899-4475-7 · Cited by 1,936
Microcomputer-based estimation of psychophysical thresholds: The Best PEST
Lieberman, H. R., & Pentland, A. P. (1982) · Behavior Research Methods & Instrumentation · doi:10.3758/bf03202110 · Cited by 318
Efficient estimation of sensory thresholds
Harvey, L. O. (1986) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03201438 · Cited by 258
Scaling of Visual Acuity Measurements
Westheimer, G. (1979) · Archives of Ophthalmology · doi:10.1001/archopht.1979.01020010173020 · Cited by 226
An Automated Visual Acuity Testing Computer Program Using the Apple II System
Friendly, D. S., & Weiss, I. P. (1985) · American Journal of Ophthalmology · doi:10.1016/0002-9394(85)90231-4 · Cited by 20
Computer automated visual acuity testing for visual screening.
Wong, D., & Plumb, A. P. (1986) · PubMed · Cited by 10
Cited by
Vision in autism spectrum disorders
Simmons, D. R., Robertson, A. E., McKay, L. S., Toal, E., McAleer, P., & Pollick, F. E. (2009) · Vision Research · doi:10.1016/j.visres.2009.08.005 · Cited by 827
Artificial vision with wirelessly powered subretinal electronic implant alpha-IMS
Stingl, K., Bartz-Schmidt, K. U., Besch, D., Braun, A., Bruckmann, A., Gekeler, F., Greppmaier, U., Hipp, S., Hörtdörfer, G., Kernstock, C., et al. (2013) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2013.0077 · Cited by 473
Binocular rivalry: frontal activity relates to introspection and action but not to perception
Frässle, S., Sommer, J., Jansen, A., Naber, M., & Einhäuser, W. (2014) · The Journal of Neuroscience · doi:10.1523/jneurosci.4403-13.2014 · Cited by 409
First-in-human trial of a novel suprachoroidal retinal prosthesis
Ayton, L. N., Blamey, P. J., Guymer, R. H., Luu, C. D., Nayagam, D. A. X., Sinclair, N. C., Shivdasani, M. N., Yeoh, J., McCombe, M. F., Briggs, R. J., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115239 · Cited by 333
Long-lasting modulation of feature integrationby transcranial magnetic stimulation
Scharnowski, F., Ruter, J., Jolij, J., Hermens, F., Kammer, T., & Herzog, M. H. (2009) · Journal of Vision · doi:10.1167/9.6.1 · Cited by 305
Metadata
- Authors
- Bach, M.
- Venue
- Optometry and Vision Science
- Publisher
- Lippincott Williams & Wilkins
- Published
- 1996-01-01
- Volume
- 73
- Issue
- 1
- Pages
- 49-53
- ISSN
- 1040-5488 (ISSN-L)
- OpenAlex
- W2013097262
- Cited by
- 984
- References
- 7
- FWCI
- 2.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Freiburg Visual Acuity Test???Automatic Measurement of Visual Acuity. https://app.cochat.ai/papers/10.1002/j.1538-9235.1996.tb04409.x
- The paper
- Bach, M. (1996). The Freiburg Visual Acuity Test???Automatic Measurement of Visual Acuity. Optometry and Vision Science. https://doi.org/10.1002/j.1538-9235.1996.tb04409.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.