The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Calcium permeability of the nicotinic acetylcholine receptor: the single-channel calcium influx is significant
Open accessAbstract
The calcium permeability of the mouse muscle nicotinic ACh receptor (nAChR) was determined using patch-clamp techniques. Single-channel currents were measured in pure external calcium and in mixtures of calcium with cesium or sodium. At low concentrations, calcium decreases the current carried by the monovalent cation. At higher concentrations, calcium displaces the monovalent cation as the main current carrier. In pure external calcium, the conductance of the nAChR is similar to the conductance of the NMDA receptor or the L-type Ca channel. With pure 110-mM calcium as the external cation, the slope conductance of the nAChR channel at negative potentials is 12 pS. An ion-permeation model based on the structure and function of the channel describes the currents. The ion-permeation model predicts that calcium contributes about 2% of the total inward current through a nAChR channel in physiologic solution. The current is about 7% of the calcium current through an L-type Ca channel. Because nAChRs are densely packed at the neuromuscular end plate, the calcium influx at an active synapse is expected to produce a locally high-calcium environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple types of neuronal calcium channels and their selective modulation
Tsien, R. W., Lipscombe, D., Madison, D. V., Bley, K. R., & Fox, A. P. (1988) · Trends in Neurosciences · doi:10.1016/0166-2236(88)90194-4 · Cited by 1,381
Ascher, P., & Nowak, L. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017078 · Cited by 819
Cited by
Mammalian nicotinic acetylcholine receptors: from structure to function
Albuquerque, E. X., Pereira, E. F. R., Alkondon, M., & Rogers, S. W. (2009) · Physiological Reviews · doi:10.1152/physrev.00015.2008 · Cited by 1,724
Seguela, P., Wadiche, J., Dineley-Miller, K., Dani, J., & Patrick, J. (1993) · The Journal of Neuroscience · doi:10.1523/jneurosci.13-02-00596.1993 · Cited by 1,471
Self-citationElgoyhen, A. B., Johnson, D. S., Boulter, J., Vetter, D. E., & Heinemann, S. (1994) · Cell · doi:10.1016/0092-8674(94)90555-x · Cited by 899
Synaptic structure and development: The neuromuscular junction
Hall, Z. W., & Sanes, J. R. (1993) · Cell · doi:10.1016/s0092-8674(05)80031-5 · Cited by 834
Calcium modulation and high calcium permeability of neuronal nicotinic acetylcholine receptors
Vernino, S., Amador, M., Luetje, C. W., Patrick, J., & Dani, J. A. (1992) · Neuron · doi:10.1016/0896-6273(92)90114-s · Cited by 469
Self-citation
Metadata
- Authors
- Decker, E., & Dani, J.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 1990-10-01
- Volume
- 10
- Issue
- 10
- Pages
- 3413-3420
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W1588765091
- Cited by
- 175
- References
- 2
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calcium permeability of the nicotinic acetylcholine receptor: the single-channel calcium influx is significant. https://app.cochat.ai/papers/10.1523/jneurosci.10-10-03413.1990
- The paper
- Decker, E., & Dani, J. (1990). Calcium permeability of the nicotinic acetylcholine receptor: the single-channel calcium influx is significant. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.10-10-03413.1990
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.