CoChat

Genetically Encoded Voltage Indicators: Opportunities and Challenges

Open access
Yang, Helen H., St-Pierre, François · 2016 · The Journal of Neuroscience
Cited by 168

The DOI matches its Crossref record; 108 of the 108 references it cites were found in a registry or an index.

Abstract

A longstanding goal in neuroscience is to understand how spatiotemporal patterns of neuronal electrical activity underlie brain function, from sensory representations to decision making. An emerging technology for monitoring electrical dynamics, voltage imaging using genetically encoded voltage indicators (GEVIs), couples the power of genetics with the advantages of light. Here, we review the properties that determine indicator performance and applicability, discussing both recent progress and technical limitations. We then consider GEVI applications, highlighting studies that have already deployed GEVIs for biological discovery. We also examine which classes of biological questions GEVIs are primed to address and which ones are beyond their current capabilities. As GEVIs are further developed, we anticipate that they will become more broadly used by the neuroscience community to eavesdrop on brain activity with unprecedented spatiotemporal resolution. SIGNIFICANCE STATEMENT Genetically encoded voltage indicators are engineered light-emitting protein sensors that typically report neuronal voltage dynamics as changes in brightness. In this review, we systematically discuss the current state of this emerging method, considering both its advantages and limitations for imaging neural activity. We also present recent applications of this technology and discuss what is feasible now and what we anticipate will become possible with future indicator development. This review will inform neuroscientists of recent progress in the field and help potential users critically evaluate the suitability of genetically encoded voltage indicator imaging to answer their specific biological questions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1523/jneurosci.1095-16.2016

Cites

108 of 108 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Ultrasensitive fluorescent proteins for imaging neuronal activity

    Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474 · cited 1×

    “This technology, called 3D random access multiphoton imaging, has been reported to enable imaging of 50,000 points per second, suggesting it could be used to follow up to 50 neurons with 1 kHz temporal resolution (Katona et al., 2012; Cotton et al., 2013).”
    Method
  • Millisecond-timescale, genetically targeted optical control of neural activity

    Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861 · cited 2×

    “In particular, the ability to combine GEVIs with optogenetics (Boyden et al., 2005) would enable all-optical interrogation of neural circuits (for review, see Emiliani et al., 2015).”
    Background
  • Deep tissue two-photon microscopy

    Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153 · cited 2×

    “Compatibility with deep-tissue imaging techniques As a result of light scattering and absorption, imaging with linear (one-photon) illumination is typically limited to 100 m below the tissue surface (Helmchen and Denk, 2005), with redshifted wavelengths typically enabling deeper imaging.”
    Background
  • A guide to choosing fluorescent proteins

    Shaner, N. C., Steinbach, P. A., & Tsien, R. Y. (2005) · Nature Methods · doi:10.1038/nmeth819 · Cited by 2,840 · cited 2×

    “Of note, the brightness and photostability of fluorescent proteins and GEVIs can differ based on illumination conditions, including light source (e.g., halogen lamp, onephoton laser, or two-photon laser), intensity, wavelength, and time-varying modulation (Shaner et al., 2005; Dean et al., 2011).”
    Background
  • Synaptic computation

    Abbott, L. F., & Regehr, W. G. (2004) · Nature · doi:10.1038/nature03010 · Cited by 1,684

  • A high signal-to-noise Ca2+ probe composed of a single green fluorescent protein

    Nakai, J., Ohkura, M., & Imoto, K. (2001) · Nature Biotechnology · doi:10.1038/84397 · Cited by 1,616 · cited 1×

    “Indeed, unlike the GCaMP/RCaMP and GECO series of calcium indicators, many of the most sensitive GEVIs become dimmer upon depolarization (Nakai et al., 2001; Zhao et al., 2011; St-Pierre et al., 2015).”
    Background
  • A bright monomeric green fluorescent protein derived from Branchiostoma lanceolatum

    Shaner, N. C., Lambert, G. G., Chammas, A., Ni, Y., Cranfill, P. J., Baird, M. A., Sell, B. R., Allen, J. R., Day, R. N., Israelsson, M., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2413 · Cited by 1,289 · cited 3×

    “However, improved brightness can come at the expense of other properties, such as photostability under laser illumination (Shaner et al., 2013) and membrane localization in neurons (Perron et al.”
    Background
  • An Expanded Palette of Genetically Encoded Ca 2+ Indicators

    Zhao, Y., Araki, S., Wu, J., Teramoto, T., Chang, Y.-F., Nakano, M., Abdelfattah, A. S., Fujiwara, M., Ishihara, T., Nagai, T., et al. (2011) · Science · doi:10.1126/science.1208592 · Cited by 1,260 · cited 1×

    “Indeed, unlike the GCaMP/RCaMP and GECO series of calcium indicators, many of the most sensitive GEVIs become dimmer upon depolarization (Nakai et al., 2001; Zhao et al., 2011; St-Pierre et al., 2015).”
    Background
  • DENDRITIC COMPUTATION

    London, M., & Häusser, M. (2005) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.28.061604.135703 · Cited by 1,149 · cited 1×

    “Studies of dendritic integration have demonstrated that, through active spikes and passive filtering, dendritic trees perform computations, such as logical operations (e.g., AND, OR, and AND-NOT) and summation (for review, see London and Häusser, 2005; Stuart and Spruston, 2015).”
  • Transgenic mice for intersectional targeting of neural sensors and effectors with high specificity and performance

    Madisen, L., Garner, A. R., Shimaoka, D., Chuong, A. S., Klapoetke, N. C., Li, L., van der Bourg, A., Niino, Y., Egolf, L., Monetti, C., et al. (2015) · Neuron · doi:10.1016/j.neuron.2015.02.022 · Cited by 1,114

Show all 108 references

Cited by

Metadata

Authors
Yang, H. H., & St-Pierre, F.
Venue
The Journal of Neuroscience
Published
2016-09-28
Volume
36
Issue
39
Pages
9977-9989
ISSN
  • 0270-6474 (ISSN-L)
  • 1529-2401
OpenAlex
W2525787459
Cited by
168
References
108
FWCI
10.27
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.