A critical band filter in touch
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Separate mechanoreceptor systems in humans were isolated by varying the spectra of vibrotactile stimuli. First, the function relating threshold to frequency of a sinusoid was obtained on the fingertip for each of four subjects, and it was found to comprise two limbs: a Pacinian and a non-Pacinian limb. The peak sensitivity within the Pacinian limb (mediated by Pacinian corpuscles) was around 250 Hz and spanned the region from 65 to 400 Hz. The non-Pacinian limb showed no detectable change in sensitivity in the region between 10 and 65 Hz. These two limbs were then treated as psychophysical channels in experiments in which narrow band noise and individual sinusoids were used to excite one or both channels. In the second and third experiments, the noise stimuli varied in bandwidth from 8 to 70 Hz and varied in center frequency from 25 to 218 Hz. Masking functions were obtained for ON- frequency conditions (the sinusoidal test and noise masker occupied the same frequency region) and for OFF-frequency conditions (the test and masker occupied different frequency regions). The ON-frequency experiments were used to estimate the signal-to-noise ratio (S/N) of the Pacinian channel at threshold. The OFF-frequency masking experiments were used to infer the shape of the Pacinian channel at frequencies below 65 Hz, where thresholds for Pacinian activation were above detection threshold. The results of these three experiments predicted the findings of a fourth masking experiment with a parameter free model that treated the Pacinian channel as a filter that integrates stimulus power. The results show that the Pacinian channel is analogous to a critical band in the auditory system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Johansson, R. S., & Vallbo, A. B. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012619 · Cited by 1,291 · cited 1×
“This might have resulted from differences in stimulus locations, since we stimulated the distal pad of the index finger, where there are nearly twice the density of Pacinian corpuscles as in the thenar eminence (Johansson and Vallbo, 1979).”
BackgroundFour channels mediate the mechanical aspects of touch
Bolanowski, S. J., Gescheider, G. A., Verrillo, R. T., & Checkosky, C. M. (1988) · The Journal of the Acoustical Society of America · doi:10.1121/1.397184 · Cited by 937
Parallel visual pathways: A review
Lennie, P. (1980) · Vision Research · doi:10.1016/0042-6989(80)90115-7 · Cited by 509
Cited by
The Role of Fingerprints in the Coding of Tactile Information Probed with a Biomimetic Sensor
Scheibert, J., Leurent, S., Prevost, A., & Debrégeas, G. (2009) · Science · doi:10.1126/science.1166467 · Cited by 418
Tactile brush: drawing on skin with a tactile grid display
Israr, A., & Poupyrev, I. (2011) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1978942.1979235 · Cited by 354
A volumetric display for visual, tactile and audio presentation using acoustic trapping
Hirayama, R., Martinez Plasencia, D., Masuda, N., & Subramanian, S. (2019) · Nature · doi:10.1038/s41586-019-1739-5 · Cited by 331
Feeling small: exploring the tactile perception limits
Skedung, L., Arvidsson, M., Chung, J. Y., Stafford, C. M., Berglund, B., & Rutland, M. W. (2013) · Scientific Reports · doi:10.1038/srep02617 · Cited by 285
“The optimal sensing vibration frequency, f o , of the fast adapting receptors is around 250 Hz 37,38 so the arbitrary lower limit of v 5 10 mm/s yields l 5 40 m m as the ‘‘excitation’’ wavelength.”
BackgroundBensmaÏa, S. J., & Hollins, M. (2003) · Somatosensory & Motor Research · doi:10.1080/0899022031000083825 · Cited by 280
Metadata
- Authors
- Makous, J., Friedman, R., & Vierck, C.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 1995-04-01
- Volume
- 15
- Issue
- 4
- Pages
- 2808-2818
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W1529830795
- Cited by
- 130
- References
- 3
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A critical band filter in touch. https://app.cochat.ai/papers/10.1523/jneurosci.15-04-02808.1995
- The paper
- Makous, J., Friedman, R., & Vierck, C. (1995). A critical band filter in touch. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.15-04-02808.1995
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.