The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Reliability and Precision of the Mouse Calyx of Held Synapse
Open accessAbstract
Traditionally, the calyx of Held synapse is viewed as a highly reliable relay in the sound localization circuit of the auditory brainstem, with every presynaptic action potential triggering a postsynaptic action potential in vivo. However, this view is at odds with slice recordings that report large short-term depression (STD). To investigate the reliability and precision of this synapse, we compared slice and in vivo recordings from medial nucleus of the trapezoid body neurons of young adult mice. We show that the extracellularly recorded complex waveform can be used to estimate both presynaptic release and postsynaptic excitability. Whereas under standard slice conditions the synapse underwent large STD, both extracellular and whole-cell recordings indicated that in vivo the size of the EPSPs was independent of recent history. The estimated quantal content was typically <20 in vivo, much lower than in the resting synapse under standard slice conditions. However, due to the large quantal size and summation of EPSPs, the safety factor of this synapse was generally still sufficiently large and postsynaptic failures were observed only infrequently in vivo. When present, failures were typically due to stochastic fluctuations in EPSP size or postsynaptic spike depression.In vivo, the calyx of Held synapse thus functions as a tonic synapse. The price it pays for its low release probability is an increase in jitter and synaptic latency and occasional postsynaptic failures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
Contribution of the Kv3.1 potassium channel to high‐frequency firing in mouse auditory neurones
Wang, L., Gan, L., Forsythe, I. D., & Kaczmarek, L. K. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.183bo.x · Cited by 357
Jones, H. C., & Keep, R. F. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017223 · Cited by 164
Cited by
Synaptic vesicle recycling: steps and principles
Rizzoli, S. O. (2014) · The EMBO Journal · doi:10.1002/embj.201386357 · Cited by 317
Johnston, J., Forsythe, I. D., & Kopp-Scheinpflug, C. (2010) · The Journal of Physiology · doi:10.1113/jphysiol.2010.191973 · Cited by 290
Ultrafast endocytosis at Caenorhabditis elegans neuromuscular junctions
Watanabe, S., Liu, Q., Davis, M. W., Hollopeter, G., Thomas, N., Jorgensen, N. B., & Jorgensen, E. M. (2013) · eLife · doi:10.7554/elife.00723 · Cited by 248
Bassoon speeds vesicle reloading at a central excitatory synapse
Hallermann, S., Fejtova, A., Schmidt, H., Weyhersmüller, A., Silver, R. A., Gundelfinger, E. D., & Eilers, J. (2010) · Neuron · doi:10.1016/j.neuron.2010.10.026 · Cited by 223
Blosa, M., Sonntag, M., Jäger, C., Weigel, S., Seeger, J., Frischknecht, R., Seidenbecher, C. I., Matthews, R. T., Arendt, T., Rübsamen, R., et al. (2015) · The Journal of Physiology · doi:10.1113/jp270849 · Cited by 74
Metadata
- Authors
- Lorteije, J. A. M., Rusu, S. I., Kushmerick, C., & Borst, J. G. G.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 2009-11-04
- Volume
- 29
- Issue
- 44
- Pages
- 13770-13784
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W2075765459
- Cited by
- 191
- References
- 3
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability and Precision of the Mouse Calyx of Held Synapse. https://app.cochat.ai/papers/10.1523/jneurosci.3285-09.2009
- The paper
- Lorteije, J. A. M., Rusu, S. I., Kushmerick, C., & Borst, J. G. G. (2009). Reliability and Precision of the Mouse Calyx of Held Synapse. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.3285-09.2009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.