Reliability and Precision of the Mouse Calyx of Held Synapse
Open accessThe DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
Traditionally, the calyx of Held synapse is viewed as a highly reliable relay in the sound localization circuit of the auditory brainstem, with every presynaptic action potential triggering a postsynaptic action potential in vivo. However, this view is at odds with slice recordings that report large short-term depression (STD). To investigate the reliability and precision of this synapse, we compared slice and in vivo recordings from medial nucleus of the trapezoid body neurons of young adult mice. We show that the extracellularly recorded complex waveform can be used to estimate both presynaptic release and postsynaptic excitability. Whereas under standard slice conditions the synapse underwent large STD, both extracellular and whole-cell recordings indicated that in vivo the size of the EPSPs was independent of recent history. The estimated quantal content was typically <20 in vivo, much lower than in the resting synapse under standard slice conditions. However, due to the large quantal size and summation of EPSPs, the safety factor of this synapse was generally still sufficiently large and postsynaptic failures were observed only infrequently in vivo. When present, failures were typically due to stochastic fluctuations in EPSP size or postsynaptic spike depression.In vivo, the calyx of Held synapse thus functions as a tonic synapse. The price it pays for its low release probability is an increase in jitter and synaptic latency and occasional postsynaptic failures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
Synaptic depression and cortical gain control
Abbott, L. F., Varela, J. A., Sen, K., & Nelson, S. B. (1997) · Science · doi:10.1126/science.275.5297.221 · Cited by 1,690
Tsodyks, M. V., & Markram, H. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.2.719 · Cited by 1,603
Effect of anoxia on ion distribution in the brain
Hansen, A. J. (1985) · Physiological Reviews · doi:10.1152/physrev.1985.65.1.101 · Cited by 1,346 · cited 1×
“5 mM, which should be close to the physiological concentration in the interstitial fluid (Hansen, 1985; Jones and Keep, 1988; Silver and Erecińska, 1990), STD was reduced, but a clear fast recovery component was A B”
BackgroundHarris, K. D., Henze, D. A., Csicsvari, J., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,151 · cited 1×
“The systematic changes in waveform we observed due to spike depression will significantly hinder attempts to unambiguously identify individual units in multiunit recordings (Harris et al., 2000).”
BackgroundNeural Networks with Dynamic Synapses
Tsodyks, M., Pawelzik, K., & Markram, H. (1998) · Neural Computation · doi:10.1162/089976698300017502 · Cited by 942
Multiple Roles of Calcium Ions in the Regulation of Neurotransmitter Release
Neher, E., & Sakaba, T. (2008) · Neuron · doi:10.1016/j.neuron.2008.08.019 · Cited by 927
Horikawa, K., & Armstrong, W. E. (1988) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(88)90114-8 · Cited by 881
Redistribution of synaptic efficacy between neocortical pyramidal neurons
Markram, H., & Tsodyks, M. (1996) · Nature · doi:10.1038/382807a0 · Cited by 853
Calcium influx and transmitter release in a fast CNS synapse
Borst, J. G. G., & Sakmann, B. (1996) · Nature · doi:10.1038/383431a0 · Cited by 631 · cited 9×
“If quantal content was calculated as the ratio between the peak amplitude of evoked and spontaneous EPSCs (Borst and Sakmann, 1996), a value of only 13 1 was obtained at the steady-state level of the 500 Hz train (Table S3, available at www.”
BackgroundResultInfluentialSelf-citation
Cited by
Synaptic vesicle recycling: steps and principles
Rizzoli, S. O. (2014) · The EMBO Journal · doi:10.1002/embj.201386357 · Cited by 317
“The probability for a vesicle to be released by a single impulse is rather low, only about 10% (Slater et al , 1992) (see also Lorteije et al , 2009 for a CNS synapse).”
Johnston, J., Forsythe, I. D., & Kopp-Scheinpflug, C. (2010) · The Journal of Physiology · doi:10.1113/jphysiol.2010.191973 · Cited by 290
Ultrafast endocytosis at Caenorhabditis elegans neuromuscular junctions
Watanabe, S., Liu, Q., Davis, M. W., Hollopeter, G., Thomas, N., Jorgensen, N. B., & Jorgensen, E. M. (2013) · eLife · doi:10.7554/elife.00723 · Cited by 248
“Moreover, in some central synapses such as the Calyx of Held, firing rates can reach up to 500 Hz (Kopp-Scheinpflug et al., 2008; Lorteije et al., 2009).”
BackgroundSynaptic vesicle pools: an update
Denker (2010) · Frontiers in Synaptic Neuroscience · doi:10.3389/fnsyn.2010.00135 · Cited by 248
“Interestingly, it still seems to have a rather small quantal content in vivo (less than 20 vesicles, Lorteije et al., 2009), indicating that very few of its ∼550 active zones (Sätzler et al., 2002) release a vesicle at any one time.”
The Calyx of Held Synapse: From Model Synapse to Auditory Relay
Borst, J. G. G., & Soria van Hoeve, J. (2012) · Annual Review of Physiology · doi:10.1146/annurev-physiol-020911-153236 · Cited by 224
Self-citationBassoon speeds vesicle reloading at a central excitatory synapse
Hallermann, S., Fejtova, A., Schmidt, H., Weyhersmüller, A., Silver, R. A., Gundelfinger, E. D., & Eilers, J. (2010) · Neuron · doi:10.1016/j.neuron.2010.10.026 · Cited by 223
Neher, E. (2010) · Frontiers in Synaptic Neuroscience · doi:10.3389/fnsyn.2010.00144 · Cited by 199
“Remarkably, the same quantal content was found for recordings in 2 mM external (Ca2+) and in 1.2 mM external (Ca2+) (Lorteije et al., 2009), although release probability under the latter condition is quite low.”
InfluentialThe low synaptic release probability in vivo
Borst, J. G. G. (2010) · Trends in Neurosciences · doi:10.1016/j.tins.2010.03.003 · Cited by 174
Self-citationPala, A., & Petersen, C. C. H. (2015) · Neuron · doi:10.1016/j.neuron.2014.11.025 · Cited by 160
“in Layer 2/3 Mouse Barrel Cortex”
Blosa, M., Sonntag, M., Jäger, C., Weigel, S., Seeger, J., Frischknecht, R., Seidenbecher, C. I., Matthews, R. T., Arendt, T., Rübsamen, R., et al. (2015) · The Journal of Physiology · doi:10.1113/jp270849 · Cited by 74
“Also, simultaneous intra- and extracellular recordings of MNTB principal neurons and bushy cells in the anterior ventral cochlear nucleus (AVCN) have shown that activity acquired extracellularly reliably indicates intracellular voltage changes (Lorteije et al. 2009; Typlt et al. 2010).”
BackgroundMethodInfluentialKrohs, C., Körber, C., Ebbers, L., Altaf, F., Hollje, G., Hoppe, S., Dörflinger, Y., Prosser, H. M., & Nothwang, H. G. (2021) · The Journal of Neuroscience · doi:10.1523/jneurosci.0139-20.2021 · Cited by 15
Metadata
- Authors
- Lorteije, J. A. M., Rusu, S. I., Kushmerick, C., & Borst, J. G. G.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 2009-11-04
- Volume
- 29
- Issue
- 44
- Pages
- 13770-13784
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W2075765459
- Cited by
- 191
- References
- 74
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.