Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 193

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

The Reliability and Validity of the Alcohol Use Disorders Identification Test (AUDIT) in a German General Practice Population Sample

Dybek, Inga, Bischof, Gallus, Grothues, Janina, Reinhardt, Susa, Meyer, Christian, Hapke, Ulfert, John, Ulrich, Broocks, Andreas, Hohagen, Fritz, Rumpf, Hans-Jürgen · 2006 · Journal of Studies on Alcohol

Abstract

OBJECTIVE: Our goal was to analyze the retest reliability and validity of the Alcohol Use Disorders Identification Test (AUDIT) in a primary-care setting and recommend a cut-off value for the different alcohol-related diagnoses. METHOD: Participants recruited from general practices (GPs) in two northern German cities received the AUDIT, which was embedded in a health-risk questionnaire. In total, 10,803 screenings were conducted. The retest reliability was tested on a subsample of 99 patients, with an intertest interval of 30 days. Sensitivity and specificity at a number of different cut-off values were estimated for the sample of alcohol consumers (n=8237). For this study, 1109 screen-positive patients received a diagnostic interview. Individuals who scored less than five points in the AUDIT and also tested negative in a second alcohol-related screen were defined as "negative" (n=6003). This definition was supported by diagnostic interviews of 99 screen-negative patients from which no false negatives could be detected. As the gold standard for detection of an alcohol-use disorder (AUD), we used the Munich-Composite International Diagnostic Interview (MCIDI), which is based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, criteria. RESULTS: On the item level, the reliability, measured by the intraclass correlation coefficient (ICC), ranged between .39 (Item 9) and .98 (Item 10). For the total score, the ICC was .95. For cut-off values of eight points and five points, 87.5% and 88.9%, respectively, of the AUDIT-positives, and 98.9% and 95.1%, respectively, of the AUDIT-negatives were identically identified at retest, with kappa = .86 and kappa = .81. At the cut-off value of five points, we determined good combinations of sensitivity and specificity for the following diagnoses: alcohol dependence (sensitivity and specificity of .97 and .88, respectively), AUD (.97 and .92), and AUD and/or at-risk consumption (.97 and .91). CONCLUSIONS: Embedded in a health-risk questionnaire in primary-care settings, the AUDIT is a reliable and valid screening instrument to identify at-risk drinkers and patients with an AUD. Our findings strongly suggest a lowering of the recommended cut-off value of eight points.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.15288/jsa.2006.67.473

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 193

Metadata

Authors
Dybek, I., Bischof, G., Grothues, J., Reinhardt, S., Meyer, C., Hapke, U., John, U., Broocks, A., Hohagen, F., & Rumpf, H.-J.
Venue
Journal of Studies on Alcohol
Published
2006-05
Volume
67
Issue
3
Pages
473-481
ISSN
  • 0096-882X (ISSN-L)
  • 1934-2683
OpenAlex
W1987804832
Cited by
193
References
5
FWCI
4.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.