The DOI matches its Crossref record.
Mapping the Number of Molecules and Brightness in the Laser Scanning Microscope
Open accessAbstract
We describe a technique based on moment-analysis for the measurement of the average number of molecules and brightness in each pixel in fluorescence microscopy images. The average brightness of the particle is obtained from the ratio of the variance to the average intensity at each pixel. To obtain the average number of fluctuating particles, we divide the average intensity at one pixel by the brightness. This analysis can be used in a wide range of concentrations. In cells, the intensity at any given pixel may be due to bright immobile structures, dim fast diffusing particles, and to autofluorescence or scattering. The total variance is given by the variance of each of the above components in addition to the variance due to detector noise. Assuming that all sources of variance are independent, the total variance is the sum of the variances of the individual components. The variance due to the particles fluctuating in the observation volume is proportional to the square of the particle brightness while the variance of the immobile fraction, the autofluorescence, scattering, and that of the detector is proportional to the intensity of these components. Only the fluctuations that depend on the square of the brightness (the mobile particles) will have a ratio of the variance to the intensity >1. Furthermore, changing the fluorescence intensity by increasing the illumination power, distinguishes between these possible contributions. We show maps of molecular brightness and number of cell migration proteins obtained using a two-photon scanning microscope operating with a photon-counting detector. These brightness maps reveal binding dynamics at the focal adhesions with pixel resolution and provide a picture of the binding and unbinding process in which dim molecules attach to the adhesions or large molecular aggregates dissociate from adhesion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dynamic regulation of transcriptional states by chromatin and transcription factors
Voss, T. C., & Hager, G. L. (2014) · Nature Reviews Genetics · doi:10.1038/nrg3623 · Cited by 504
Fluorescence Correlation Spectroscopy: Past, Present, Future
Elson, E. L. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.11.012 · Cited by 438
Taylor, A. M. W., Castonguay, A., Ghogha, A., Vayssiere, P., Pradhan, A. A. A., Xue, L., Mehrabani, S., Wu, J., Levitt, P., Olmstead, M. C., et al. (2016) · Neuropsychopharmacology · doi:10.1038/npp.2015.221 · Cited by 109
(2019) · doi:10.1038/s41467-019-10734-8 · Cited by 75
Yoon, Y., Zhang, X., & Cho, W. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m112.372789 · Cited by 47
Metadata
- Authors
- Digman, M. A., Dalal, R., Horwitz, A. F., & Gratton, E.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2008-03
- Volume
- 94
- Issue
- 6
- Pages
- 2320-2332
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2016189813
- Cited by
- 475
- References
- 0
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mapping the Number of Molecules and Brightness in the Laser Scanning Microscope. https://app.cochat.ai/papers/10.1529/biophysj.107.114645
- The paper
- Digman, M. A., Dalal, R., Horwitz, A. F., & Gratton, E. (2008). Mapping the Number of Molecules and Brightness in the Laser Scanning Microscope. Biophysical Journal. https://doi.org/10.1529/biophysj.107.114645
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.