Mapping the Number of Molecules and Brightness in the Laser Scanning Microscope
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
We describe a technique based on moment-analysis for the measurement of the average number of molecules and brightness in each pixel in fluorescence microscopy images. The average brightness of the particle is obtained from the ratio of the variance to the average intensity at each pixel. To obtain the average number of fluctuating particles, we divide the average intensity at one pixel by the brightness. This analysis can be used in a wide range of concentrations. In cells, the intensity at any given pixel may be due to bright immobile structures, dim fast diffusing particles, and to autofluorescence or scattering. The total variance is given by the variance of each of the above components in addition to the variance due to detector noise. Assuming that all sources of variance are independent, the total variance is the sum of the variances of the individual components. The variance due to the particles fluctuating in the observation volume is proportional to the square of the particle brightness while the variance of the immobile fraction, the autofluorescence, scattering, and that of the detector is proportional to the intensity of these components. Only the fluctuations that depend on the square of the brightness (the mobile particles) will have a ratio of the variance to the intensity >1. Furthermore, changing the fluorescence intensity by increasing the illumination power, distinguishes between these possible contributions. We show maps of molecular brightness and number of cell migration proteins obtained using a two-photon scanning microscope operating with a photon-counting detector. These brightness maps reveal binding dynamics at the focal adhesions with pixel resolution and provide a picture of the binding and unbinding process in which dim molecules attach to the adhesions or large molecular aggregates dissociate from adhesion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescence correlation spectroscopy. II. An experimental realization
Magde, D., Elson, E. L., & Webb, W. W. (1974) · Biopolymers · doi:10.1002/bip.1974.360130103 · Cited by 1,512
Fluorescence correlation spectroscopy. I. Conceptual basis and theory
Elson, E. L., & Magde, D. (1974) · Biopolymers · doi:10.1002/bip.1974.360130102 · Cited by 1,436
Fluorescence Correlation Spectroscopy
(2011) · SpringerReference · doi:10.1007/springerreference_33960 · Cited by 714
The Photon Counting Histogram in Fluorescence Fluctuation Spectroscopy
Chen, Y., Müller, J. D., So, P. T. C., & Gratton, E. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76912-2 · Cited by 682
Self-citationBerland, K. M., So, P. T., & Gratton, E. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80230-4 · Cited by 490
Self-citationFluorescence correlation spectroscopy with single-molecule sensitivity on cell and model membranes
Schwille, P., Korlach, J., & Webb, W. W. (1999) · Cytometry · doi:10.1002/(sici)1097-0320(19990701)36:3<176::aid-cyto5>3.0.co;2-f · Cited by 487
Measuring Fast Dynamics in Solutions and Cells with a Laser Scanning Microscope
Digman, M. A., Brown, C. M., Sengupta, P., Wiseman, P. W., Horwitz, A. R., & Gratton, E. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.062836 · Cited by 462
Self-citationPhotobleaching-Corrected FRET Efficiency Imaging of Live Cells
Zal, T., & Gascoigne, N. R. J. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.022087 · Cited by 399
Measurement of FRET Efficiency and Ratio of Donor to Acceptor Concentration in Living Cells
Chen, H., Puhl, H. L., Koushik, S. V., Vogel, S. S., & Ikeda, S. R. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.088773 · Cited by 263
Wiseman, P. W., Brown, C. M., Webb, D. J., Hebert, B., Johnson, N. L., Squier, J. A., Ellisman, M. H., & Horwitz, A. F. (2004) · Journal of Cell Science · doi:10.1242/jcs.01416 · Cited by 232
Self-citation
Cited by
Phase separation drives heterochromatin domain formation
Strom, A. R., Emelyanov, A. V., Mir, M., Fyodorov, D. V., Darzacq, X., & Karpen, G. H. (2017) · Nature · doi:10.1038/nature22989 · Cited by 1,807
Dynamic regulation of transcriptional states by chromatin and transcription factors
Voss, T. C., & Hager, G. L. (2014) · Nature Reviews Genetics · doi:10.1038/nrg3623 · Cited by 504
Fluorescence Correlation Spectroscopy: Past, Present, Future
Elson, E. L. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.11.012 · Cited by 438
Phase separation provides a mechanism to reduce noise in cells
Klosin, A., Oltsch, F., Harmon, T., Honigmann, A., Jülicher, F., Hyman, A. A., & Zechner, C. (2020) · Science · doi:10.1126/science.aav6691 · Cited by 361
Honigmann, A., Mueller, V., Ta, H., Schoenle, A., Sezgin, E., Hell, S. W., & Eggeling, C. (2014) · Nature Communications · doi:10.1038/ncomms6412 · Cited by 291
Microglia Disrupt Mesolimbic Reward Circuitry in Chronic Pain
Taylor, A. M. W., Castonguay, A., Taylor, A. J., Murphy, N. P., Ghogha, A., Cook, C., Xue, L., Olmstead, M. C., De Koninck, Y., Evans, C. J., et al. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.4036-14.2015 · Cited by 187
“Briefly, following the results of previous studies (Digman et al., 2008), we converted the photon timing histograms of each acquired lifetime image to phasor plots.”
MethodFluorescence microscopy—A historical and technical perspective
Renz, M. (2013) · Cytometry Part A · doi:10.1002/cyto.a.22295 · Cited by 165
“Number and brightness analysis (57), image correlation spectroscopy (ICS) (58), and Raster ICS (59,60) allow”
BackgroundTaylor, A. M. W., Castonguay, A., Ghogha, A., Vayssiere, P., Pradhan, A. A. A., Xue, L., Mehrabani, S., Wu, J., Levitt, P., Olmstead, M. C., et al. (2016) · Neuropsychopharmacology · doi:10.1038/npp.2015.221 · Cited by 109
“Results were analyzed with a computer-assisted densitometry analysis (Image J Software, NIH).”
(2019) · doi:10.1038/s41467-019-10734-8 · Cited by 75
Yoon, Y., Zhang, X., & Cho, W. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m112.372789 · Cited by 47
Structural Modeling of GR Interactions with the SWI/SNF Chromatin Remodeling Complex and C/EBP
Muratcioglu, S., Presman, D. M., Pooley, J. R., Grøntved, L., Hager, G. L., Nussinov, R., Keskin, O., & Gursoy, A. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.06.044 · Cited by 39
Metadata
- Authors
- Digman, M. A., Dalal, R., Horwitz, A. F., & Gratton, E.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2008-03
- Volume
- 94
- Issue
- 6
- Pages
- 2320-2332
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2016189813
- Cited by
- 475
- References
- 24
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.