Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 312

The DOI matches its Crossref record.

RADIOIMMUNOASSAYS EMPLOYING IMMUNOSORBENTS

Wide, Leif·1969·Acta Endocrinologica

Abstract

The use of a reaction between compounds in a two phase system – a solid phase and a liquid phase – has simplified the technical procedure of the radioimmunoassays. Antigens or antibodies can be coupled covalently to insoluble polymers to form stable conjugates with retention of immunological binding capacity. Such immunosorbents can be used in radioimmunoassays in many different ways and with the solid phase in different forms. Some of these techniques seem to be universally applicable for the assay of antigens or antibodies. In one of these, antigens or antibodies are chemically coupled to cyanogen bromide activated insoluble polysaccharides in a particle form. This method which has several advantages when compared with most other radioimmunological methods is discussed in particular. Finally, a detailed description of the preparation of an immunosorbent and its use in such a radioimmunoassay system is given.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1530/acta.0.062s207

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 312

Metadata

Authors
Wide, L.
Venue
Acta Endocrinologica
Published
1969-12
Volume
62
Issue
1_Suppl
Pages
S207-S221
ISSN
  • 0804-4643 (ISSN-L)
  • 1479-683X
OpenAlex
W2108160925
Cited by
312
References
0
FWCI
3.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: RADIOIMMUNOASSAYS EMPLOYING IMMUNOSORBENTS. https://app.cochat.ai/papers/10.1530/acta.0.062s207
The paper
Wide, L. (1969). RADIOIMMUNOASSAYS EMPLOYING IMMUNOSORBENTS. Acta Endocrinologica. https://doi.org/10.1530/acta.0.062s207

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.