Cited by 13Neuroendocrine regulation and behaviorNeuropeptides and Animal PhysiologyAdvanced Biosensing Techniques and Applications

Solid Phase Radioimmunoassay for Direct Measurement of Human Plasma Oxytocin

Burd, J. M., Weightman, D. R., Baylis, P. H.·1985·Journal of Immunoassay

Abstract

Synthetic oxytocin (OT) conjugated to bovine thyroglobulin by the carbodiimide reaction was injected into rabbits to raise a high titre, specific OT antiserum which was then coupled to microcrystalline cellulose activated by cyanogen bromide. High affinity of the coupled antiserum was defined by Scatchard analysis, Keq = 7.1 X 10(11)1/mol. Cross-reactivity studies revealed little binding of antiserum to analogues of OT. Iodination was performed by the Chloramine T method, giving specific activity of 125I-OT, range 1.1 - 1.7 X 10(3) Ci/mmol. After incubation for 40 hours under disequilibrium conditions, specific and non-specific bindings were 10.6 +/- 2.7% and 0.2 +/- 0.1% (n=15), respectively. Displacement of 50% 125I-OT occurred with 2.9 pg OT/tube. Coefficients of variation of standard OT concentrations (0.03 - 16 pg/tube) were less than 5%. Limit of detection was 2 pg OT/ml plasma. Recovery of synthetic OT added to non-pregnant plasma was 81.8% (n=34) at 20 pg/ml and 97.4% (n=32) at 100 pg/ml. Two patients, 17 and 18 weeks post-partum, had increases in plasma OT from less than 2 pg/ml to 18.3 and 16.0 pg/ml after 6 and 4 minutes breast feeding infants, respectively. We conclude that this solid phase OT radioimmunoassay is quick, relatively sensitive and reliable, and does not require prior extraction of plasma samples.

Integrity signals

Registry

Crossref · 10.1080/01971528508063031

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • By the 1980s, many laboratories had generated radioimmunoassays for oxytocin using independently produced antibodies, and most but not all required extraction.

    “By the 1980s, many laboratories had generated radioimmunoassays for oxytocin, using independently produced antibodies 58, 72, 73, 74, 94, 95, 96, 97, 98] and most, but not all 99, 100, required extraction.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Burd, J. M., Weightman, D. R., & Baylis, P. H.
Affiliations
Royal Victoria Infirmary (GB)
Venue
Journal of Immunoassay
Published
1985-09
Volume
6
Issue
3
Pages
227-243
ISSN
0197-1522 (ISSN-L)
OpenAlex
W1999981074
Cited by
13
References
16
Citations by year
2025: 1 · 2016: 1 · 2013: 1
FWCI
1.92
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Immunoassay (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Social Sciences › Psychology › Social Psychology › Neuroendocrine regulation and behavior
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuropeptides and Animal Physiology
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
Keywords
oxytocin, solid-phase radioimmunoassay, bovine thyroglobulin, iodination, displacement assay, breastfeeding
MeSH terms
Antibody Specificity, Cross Reactions, Dose-Response Relationship, Immunologic, Female, Humans, Immunosorbent Techniques, Lactation, Oxytocin, Pregnancy, Radioimmunoassay

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review