CoChat

A purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17β-estradiol in prepubertal children

Ankarberg-Lindgren, Carina, Norjavaara, Ensio · 2008 · European Journal of Endocrinology
Cited by 57

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Objective: To test the clinical usefulness of sensitive commercial immunoassays for determination of low 17β-estradiol concentrations in children. Methods: The lower limit of detection and clinical usefulness (functional sensitivity) of three commercial estradiol immunoassays were validated by use of 500 sera from prepubertal and pubertal children and 55 pooled sera. The three immunoassays consisted of two modified direct immunoassays; one RIA (Spectria Estradiol RIA) and one time-resolved fluoroimmunoassay (AutoDELFIA Estradiol), both with increased serum volume in relation to antibody concentration and extended incubation time. In the third method, serum was purified and concentrated using diethyl ether extraction prior to measurement by the modified Spectria Estradiol RIA. Results: The lower limits of detection and clinical usefulness were 9 and 30 pmol/l for the direct RIA, 11 and 50 pmol/l for the AutoDELFIA, and 4 and 6 pmol/l for serum determined by extraction RIA. When measuring the serum pool originating from girls at breast stages 1–2, the direct RIA and AutoDELFIA resulted in significantly higher 17β-estradiol concentrations when compared with the extraction RIA (+58 and +267%,P<0.001). We found a significant difference in 17β-estradiol concentrations between girls at breast stages 1 (median 6 pmol/l) and 2 (median 16 pmol/l), when quantified by the extraction RIA (P<0.0001) but no difference when quantified with the direct RIA (median values 12 and 14 pmol/l respectively). Conclusion: For determination of low serum 17β-estradiol concentrations in children, an extraction step prior to commercial immunoassay is needed to achieve clinically useful results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1530/eje-07-0403

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 57

Metadata

Authors
Ankarberg-Lindgren, C., & Norjavaara, E.
Venue
European Journal of Endocrinology
Published
2008-01
Volume
158
Issue
1
Pages
117-124
ISSN
  • 0804-4643 (ISSN-L)
  • 1479-683X
OpenAlex
W2146680184
Cited by
57
References
1
FWCI
3.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17β-estradiol in prepubertal children. https://app.cochat.ai/papers/10.1530/eje-07-0403
The paper
Ankarberg-Lindgren, C., & Norjavaara, E. (2008). A purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17β-estradiol in prepubertal children. European Journal of Endocrinology. https://doi.org/10.1530/eje-07-0403

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.