Diagnostic accuracy of free and total metanephrines in plasma and fractionated metanephrines in urine of patients with pheochromocytoma
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Plasma free and urinary metanephrines are recognized biomarkers for the assessment of pheochromocytoma. Plasma total metanephrines with a long half-life may represent another useful biomarker. Objective: The aim of this study is to evaluate the diagnostic performances of plasma total metanephrines alone or combined with free metanephrines and fractionated 24-h urinary metanephrines. Methods: A retrospective, case–control diagnostic test study was conducted between 1999 and 2007 in two university hospitals in Switzerland and two institutions in France. The patients included 46 cases with histologically proven pheochromocytoma, and 181 controls suspected of tumor with negative investigations and 3-year follow-up. None had renal dysfunction. Sensitivity and specificity were compared after expressing each measurement result as a ratio over its upper reference limit, adding the ratios of normetanephrine and metanephrine, and defining cut-off values of 1 or 2 for this sum. Results: Applying a cut-off value of 1, plasma free and total metanephrines and urinary fractionated metanephrines had similar sensitivities of 96% (95% confidence interval, 86–99%), 95% (85–99%), and 95% (84–99%) along with similar specificities of 89% (83–94%), 91% (84–95%), and 86% (80–91%). A cut-off of 2 for the sum of ratios over reference limit improves the specificity, and it can be used for a confirmation test based on another biomarker taken among the three biomarkers. Conclusion: All three metanephrine-based tests perform equivalently for diagnosing pheochromocytoma in the absence of renal insufficiency, and can be conveniently associated two by two for confirming/excluding tumor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biochemical Diagnosis of Pheochromocytoma: Which Test Is Best?
Lenders, J. W. M., Pacak, K., Walther, M. M., Linehan, W. M., Mannelli, M., Friberg, P., Keiser, H. R., Goldstein, D. S., & Eisenhofer, G. (2002) · JAMA · doi:10.1001/jama.287.11.1427 · Cited by 1,134
Sawka, A. M., Jaeschke, R., Singh, R. J., & Young, W. F. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-021251 · Cited by 503
Cited by
Pheochromocytoma and paraganglioma: an endocrine society clinical practice guideline
Lenders, J. W. M., Duh, Q.-Y., Eisenhofer, G., Gimenez-Roqueplo, A.-P., Grebe, S. K. G., Murad, M. H., Naruse, M., Pacak, K., & Young, W. F. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-1498 · Cited by 2,827
Därr, R., Kuhn, M., Bode, C., Bornstein, S. R., Pacak, K., Lenders, J. W. M., & Eisenhofer, G. (2017) · Endocrine · doi:10.1007/s12020-017-1300-y · Cited by 105
Screening for Adrenal-Endocrine Hypertension: Overview of Accuracy and Cost-effectiveness
Schwartz, G. L. (2011) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2011.02.001 · Cited by 36
“Test characteristics from more recent studies are summarized in table 4 (38,40,42,43).”
Background
Metadata
- Authors
- Grouzmann, E., Drouard-Troalen, L., Baudin, E., Plouin, P.-F., Muller, B., Grand, D., & Buclin, T.
- Venue
- European Journal of Endocrinology
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-05
- Volume
- 162
- Issue
- 5
- Pages
- 951-960
- ISSN
- 0804-4643 (ISSN-L)
- 1479-683X
- OpenAlex
- W2123548696
- Cited by
- 103
- References
- 2
- FWCI
- 9.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic accuracy of free and total metanephrines in plasma and fractionated metanephrines in urine of patients with pheochromocytoma. https://app.cochat.ai/papers/10.1530/eje-09-0996
- The paper
- Grouzmann, E., Drouard-Troalen, L., Baudin, E., Plouin, P.-F., Muller, B., Grand, D., & Buclin, T. (2010). Diagnostic accuracy of free and total metanephrines in plasma and fractionated metanephrines in urine of patients with pheochromocytoma. European Journal of Endocrinology. https://doi.org/10.1530/eje-09-0996
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.