Evaluation of the effectiveness of midnight serum cortisol in the diagnostic procedures for Cushing’s syndrome
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Objective: It is presently unclear whether the accuracy of midnight serum cortisol (F24) in the diagnosis of Cushing’s syndrome (CS) may be replicated under usual conditions of clinical care. The aim of the present study was to assess retrospectively the effectiveness of F24 for confirming the diagnosis in a consecutive series of 106 patients, in 78 of whom a definitive diagnosis of CS was made. Design and methods: We have compared the results of F24, urinary free cortisol (UFC) and the overnight 1 mg dexamethasone suppression test (DST) with the definitive clinical diagnosis. Receiver operating characteristic (ROC) analysis has been performed to define the best cutoff values, the sensitivity (Se) and the specificity (Sp) of the tests. Results: The best cutoff value for F24 was 8.3 μg/dl (Se 91.8%; Sp 96.4%). The best cutoff value for the DST was 4.0 μg/dl (Se 89.2%; Sp 90.9%). The best cutoff value for UFC was 238 μg/24 h (Se 73.2%; Sp 96.3%). The area under the curve of F24 was significantly greater than that of UFC, both in the overall series (P = 0.004) and in the subgroup of patients with mild CS (P = 0.02). The differences were analyzed by means of the two-tailed students’s t-test. With the thresholds generated by the ROC analysis, UFC would have failed to achieve the correct diagnosis in a significantly higher percentage of cases than F24 (20.4% vs 7.9%; P = 0.01). The difference was analyzed by means of the chi-squared test with Yates correction. Conclusions: The present results show that F24 has excellent effectiveness in the diagnostic procedures for CS in stressed conditions (patients studied in a hospital ward in a nonsleeping state). The test appears to be accurate also for patients with mild hypercortisolism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis and complications of Cushing’s syndrome: a consensus statement
Arnaldi, G., Angeli, A., Atkinson, A. B., Bertagna, X., Cavagnini, F., Chrousos, G. P., Fava, G. A., Findling, J. W., Gaillard, R. C., Grossman, A. B., et al. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030871 · Cited by 1,362
Self-citationThe Diagnosis and Differential Diagnosis of Cushing’s Syndrome and Pseudo-Cushing’s States
Newell-Price, J., Trainer, P., Besser, M., & Grossman, A. (1998) · Endocrine Reviews · doi:10.1210/edrv.19.5.0346 · Cited by 833
Nighttime salivary cortisol: a useful test for the diagnosis of Cushing's syndrome.
Papanicolaou, D. A., Mullen, N., Kyrou, I., & Nieman, L. K. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2002-020534 · Cited by 241
Subclinical Cushing's syndrome in adrenal incidentaloma.
Terzolo, Osella, Alì, Borretta, Cesario, Paccotti, & Angeli, A. (1998) · Clinical Endocrinology · doi:10.1046/j.1365-2265.1998.00357.x · Cited by 198
Self-citationWood, P. J., Barth, J. H., Freedman, D. B., Perry, L., & Sheridan, B. (1997) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329703400302 · Cited by 190
Putignano, P., Toja, P., Dubini, A., Giraldi, F. P., Corsello, S. M., & Cavagnini, F. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030312 · Cited by 182
Midnight salivary cortisol for the initial diagnosis of Cushing's syndrome of various causes.
Yaneva, M., Mosnier-Pudar, H., Dugué, M.-A., Grabar, S., Fulla, Y., & Bertagna, X. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031790 · Cited by 179
The low-dose dexamethasone suppression test: a reevaluation in patients with Cushing's syndrome
Findling, J. W., Raff, H., & Aron, D. C. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030207 · Cited by 165
Salivary cortisol for screening of Cushing's syndrome in children.
Martinelli, C. E., Sader, S. L., Oliveira, E. B., Daneluzzi, J. C., & Moreira, A. C. (1999) · Clinical Endocrinology · doi:10.1046/j.1365-2265.1999.00749.x · Cited by 114
Cited by
The diagnosis of Cushing's syndrome: an Endocrine Society Clinical Practice Guideline.
Nieman, L. K., Biller, B. M. K., Findling, J. W., Newell-Price, J., Savage, M. O., Stewart, P. M., & Montori, V. M. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-0125 · Cited by 2,718
“3–12 g/dl had 90– 92% sensitivity with specificity of 96% (63, 101).”
BackgroundLacroix, A., Feelders, R. A., Stratakis, C. A., & Nieman, L. K. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61375-1 · Cited by 1,777
Newell-Price, J., Bertagna, X., Grossman, A. B., & Nieman, L. K. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68699-6 · Cited by 1,165
Cushing’s Syndrome: important issues in diagnosis and management
Findling, J. W., & Raff, H. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-0997 · Cited by 294
Accuracy of Diagnostic Tests for Cushing’s Syndrome: A Systematic Review and Metaanalyses
Elamin, M. B., Murad, M. H., Mullan, R., Erickson, D., Harris, K., Nadeem, S., Ennis, R., Erwin, P. J., & Montori, V. M. (2008) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-0139 · Cited by 222
Metadata
- Authors
- Reimondo, G., Allasino, B., Bovio, S., Paccotti, P., Angeli, A., & Terzolo, M.
- Venue
- European Journal of Endocrinology
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-12
- Volume
- 153
- Issue
- 6
- Pages
- 803-809
- ISSN
- 0804-4643 (ISSN-L)
- 1479-683X
- OpenAlex
- W2162854479
- Cited by
- 68
- References
- 11
- FWCI
- 4.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the effectiveness of midnight serum cortisol in the diagnostic procedures for Cushing’s syndrome. https://app.cochat.ai/papers/10.1530/eje.1.02042
- The paper
- Reimondo, G., Allasino, B., Bovio, S., Paccotti, P., Angeli, A., & Terzolo, M. (2005). Evaluation of the effectiveness of midnight serum cortisol in the diagnostic procedures for Cushing’s syndrome. European Journal of Endocrinology. https://doi.org/10.1530/eje.1.02042
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.