The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Novel Nonthermal Energy Source for Surgical Epicardial Atrial Ablation: Irreversible Electroporation
Open accessAbstract
BACKGROUND: All currently used energy sources in surgical ablation for atrial fibrillation create lesions via thermal injury. We report for the first time the in vivo results of a new nonthermal modality of epicardial atrial ablation called irreversible electroporation (IRE). IRE utilizes a sequence of electrical pulses that produce permanent nonthermal damage to tissue in a few seconds with sharp borders between affected and unaffected regions. METHODS: Five pigs underwent beating heart surgical epicardial ablations of their right and/or left atrial appendages, utilizing a sequence of 8, 16, or 32 direct current pulses of 1500 to 2000 V, 100 micros each, at a frequency of 5 per second, applied between two 4-cm long parallel electrodes with an IRE pulse generator. Local temperature measurements were performed during ablations followed by electrical isolation testing by pacing. Animal hearts were excised 24 hours after surgery and processed histologically to evaluate the degree of myocardial tissue necrosis and transmurality. RESULTS: A clear demarcation line between ablated and normal tissue, with no tissue disruption or charring, was observed on gross inspection of all lesions. Staining results showed complete transmural destruction of atrial tissue at the site of the electrode application in all 10 atrial lesions, measuring a mean of 0.9 cm in depth. Each 3- to 3.5-cm long lesion was created in 1 to 4 seconds with no local temperature change and with demonstration of electrical isolation. CONCLUSIONS: We propose a new modality to perform atrial ablations, which holds the potential of providing very swift, precise, and complete transmurality with no local heating effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surgical ablation as treatment for the elimination of atrial fibrillation: a meta-analysis
Barnett, S. D., & Ad, N. (2006) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.10.020 · Cited by 294
Cited by
A Review of Basic to Clinical Studies of Irreversible Electroporation Therapy
Jiang, C., Davalos, R. V., & Bischof, J. C. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2367543 · Cited by 332
Irreversible electroporation (NanoKnife) in cancer treatment
Jourabchi, N., Beroukhim, K., Tafti, B. A., Kee, S. T., & Lee, E. W. (2014) · Gastrointestinal Intervention · doi:10.1016/j.gii.2014.02.002 · Cited by 99
Metadata
- Authors
- Lavee, J., Onik, G., Mikus, P., & Rubinsky, B.
- Venue
- The Heart Surgery Forum
- Publisher
- IMR Press
- Published
- 2007-04-01
- Volume
- 10
- Issue
- 2
- Pages
- E162-E167
- ISSN
- 1098-3511 (ISSN-L)
- 1522-6662
- OpenAlex
- W1963637632
- Cited by
- 178
- References
- 1
- FWCI
- 7.78
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Nonthermal Energy Source for Surgical Epicardial Atrial Ablation: Irreversible Electroporation. https://app.cochat.ai/papers/10.1532/hsf98.20061202
- The paper
- Lavee, J., Onik, G., Mikus, P., & Rubinsky, B. (2007). A Novel Nonthermal Energy Source for Surgical Epicardial Atrial Ablation: Irreversible Electroporation. The Heart Surgery Forum. https://doi.org/10.1532/hsf98.20061202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.