CoChat

Delivery Room Management of the Apparently Vigorous Meconium-stained Neonate: Results of the Multicenter, International Collaborative Trial

Wiswell, Thomas E., Gannon, Catherine M., Jacob, Jack, Goldsmith, Leonard, Szyld, Edgardo, Weiss, Kerry, Schutzman, David, Cleary, Gerard M., Filipov, Panayot, Kurlat, Isabel, Caballero, Carlos L., Abassi, Soraya, Sprague, Daniel, Oltorf, Charles, Padula, Michael · 2000 · Pediatrics
Cited by 737

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Objective. Disagreement exists concerning the appropriate delivery room management of the airway of vigorous meconium-stained infants. Some suggest a universal approach to intubation and suctioning of the airway in all such neonates, whereas others advocate a selective approach. We performed this investigation: 1) to assess whether intubation and suctioning of apparently vigorous, meconium-stained neonates would reduce the incidence of meconium aspiration syndrome (MAS); and 2) to determine the frequency of complications from delivery room intubation and suctioning of such infants. Methods. Inclusion criteria included: 1) gestational age ≥37 weeks; 2) birth through meconium-stained amniotic fluid of any consistency; and 3) apparent vigor immediately after birth. Subjects were randomized to be intubated and suctioned (INT) or to expectant management (EXP). Primary outcome measures included: 1) the incidence of respiratory distress, including MAS, and 2) the incidence of complications from intubation. Results. A total of 2094 neonates were enrolled from 12 participating centers (1051 INT and 1043 EXP). Meconium-stained amniotic fluid consistency was similar in both groups. Of the 149 (7.1%) infants that subsequently demonstrated respiratory distress, 62 (3.0%) had MAS and 87 (4.2%) had findings attributed to other disorders. There were no significant differences between groups in the occurrence of MAS (INT = 3.2%; EXP = 2.7%) or in the development of other respiratory disorders (INT = 3.8%; EXP = 4.5%). Of 1098 successfully intubated infants, 42 (3.8%) had a total of 51 complications of the procedure. In all cases, the complications were mild and transient in nature. Conclusions. Compared with expectant management, intubation and suctioning of the apparently vigorous meconium-stained infant does not result in a decreased incidence of MAS or other respiratory disorders. Complications of intubation are infrequent and short-lived.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1542/peds.105.1.1

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Wiswell, T. E., Gannon, C. M., Jacob, J., Goldsmith, L., Szyld, E., Weiss, K., Schutzman, D., Cleary, G. M., Filipov, P., Kurlat, I., Caballero, C. L., Abassi, S., Sprague, D., Oltorf, C., & Padula, M.
Venue
Pediatrics
Published
2000-01-01
Volume
105
Issue
1
Pages
1-7
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W2056945050
Cited by
737
References
8
FWCI
30.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.