The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
High-Flow Nasal Cannulae in the Management of Apnea of Prematurity: A Comparison With Conventional Nasal Continuous Positive Airway Pressure
Abstract
Apnea of prematurity (AOP) is frequently managed with nasal continuous positive airway pressure (NCPAP). Nasal cannula (NC) are used at low flows (<0.5 L/min) to deliver supplemental oxygen to neonates. A number of centers use high-flow nasal cannula (HFNC) in the management of AOP without measuring the positive distending pressure (PDP) generated. Objective. To determine the NC flow required to generate PDP equal to that provided by NCPAP at 6 cm H2O and to assess the effectiveness of HFNC as compared NCPAP in the management of AOP. Method. Forty premature infants, gestation 28.7 ± 0.4 weeks (mean ± standard error of mean), postconceptual age at study 30.3 ± 0.6 weeks, birth weight 1256 ± 66 g, study weight 1260 ± 63 g who were being managed with conventional NCPAP for at least 24 hours for clinically significant apnea of prematurity, were enrolled in a trial of ventilator-generated conventional NCPAP versus infant NC at flows of up to 2.5 L/min. End expiratory esophageal pressure was measured on NCPAP and on NC, and the gas flow on NC was adjusted to generate an end expiratory esophageal pressure equal to that measured on NCPAP. Two 6-hour periods were continuously recorded and the data were stored on computer. Results. The flow required to generate a comparable PDP with NC varied with the infant's weight and was represented by the equation: flow (L/min) = 0.92 + 0.68x, x = weight in kg,R = 0.72. There was no difference in the frequency and duration of apnea, bradycardia or desaturation per recording between the 2 systems. Conclusion. NC at flows of 1 to 2.5 L/min can deliver PDP in premature neonates. HFNC is as effective as NCPAP in the management of AOP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kattwinkel, J., Nearman, H. S., Fanaroff, A. A., Katona, P. G., & Klaus, M. H. (1975) · The Journal of Pediatrics · doi:10.1016/s0022-3476(75)80158-2 · Cited by 267
Inadvertent Administration of Positive End-Distending Pressure During Nasal Cannula Flow
Locke, R. G., Wolfson, M. R., Shaffer, T. H., Rubenstein, S. D., & Greenspan, J. S. (1993) · Pediatrics · doi:10.1542/peds.91.1.135 · Cited by 211
Liquid-filled esophageal catheter for measuring pleural pressure in preterm neonates
Coates, A. L., Davis, G. M., Vallinis, P., & Outerbridge, E. W. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.2.889 · Cited by 52
Cited by
Lee, J. H., Rehder, K. J., Williford, L., Cheifetz, I. M., & Turner, D. A. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2743-5 · Cited by 391
High flow nasal cannula for respiratory support in preterm infants
Wilkinson, D., Andersen, C., O'Donnell, C. P., De Paoli, A. G., & Manley, B. J. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006405.pub3 · Cited by 368
High Flow Nasal Cannulae Therapy in Infants with Bronchiolitis
McKiernan, C., Chua, L. C., Visintainer, P. F., & Allen, H. (2010) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2009.10.039 · Cited by 302
De Paoli, A. G., Davis, P. G., Argus, B., & Jackson, H. D. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002977.pub2 · Cited by 298
Ekhaguere, O. A., Mairami, A. B., & Kirpalani, H. (2019) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2018.04.004 · Cited by 42
Metadata
- Authors
- Sreenan, C., Lemke, R. P., Hudson-Mason, A., & Osiovich, H.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2001-05-01
- Volume
- 107
- Issue
- 5
- Pages
- 1081-1083
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2161184431
- Cited by
- 329
- References
- 3
- FWCI
- 4.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Flow Nasal Cannulae in the Management of Apnea of Prematurity: A Comparison With Conventional Nasal Continuous Positive Airway Pressure. https://app.cochat.ai/papers/10.1542/peds.107.5.1081
- The paper
- Sreenan, C., Lemke, R. P., Hudson-Mason, A., & Osiovich, H. (2001). High-Flow Nasal Cannulae in the Management of Apnea of Prematurity: A Comparison With Conventional Nasal Continuous Positive Airway Pressure. Pediatrics. https://doi.org/10.1542/peds.107.5.1081
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.