Endotracheal Intubation Attempts During Neonatal Resuscitation: Success Rates, Duration, and Adverse Effects
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE. Endotracheal intubation of newborn infants is a mandatory competence for many pediatric trainees. The Neonatal Resuscitation Program recommends a 20-second limit for intubation attempts. Intubation attempts by junior doctors are frequently unsuccessful, and many infants are intubated between 20 and 30 seconds without apparent adverse effect. Little is known about the proficiency of more senior medical staff, the time taken to determine endotracheal tube (ETT) position, or the effects of attempted intubation on infants' heart rate (HR) and oxygen saturation (Spo2) in the delivery room (DR). The objectives of this study were to determine (1) the success rates and duration of intubation attempts during DR resuscitation, (2) whether experience is associated with greater success rates and shorter time taken to intubate, (3) the time taken to identify ETT position after intubation, and (4) the frequency with which infants deteriorated during intubation attempts and the time at which this occurred. METHODS. We reviewed videos of DR resuscitations; identified whether intubation was attempted; and, when attempted, whether intubation was attempted by a resident, a fellow, or a consultant. We defined the duration of an intubation attempt as the time from the introduction of the laryngoscope blade to the mouth to its removal, regardless of whether an ETT was introduced. We determined the time from removal of the laryngoscope to the clinicians' decision as to whether the intubation was successful and noted the basis on which this decision was made (clinical assessment, flow signals, or exhaled carbon dioxide [ETCO2] detection). We determined success according to clinical signs in all cases and used flow signals that were obtained during ventilation via the ETT or ETCO2 when available. When neither was available, the chest radiograph on admission to the NICU was reviewed. For infants who were monitored with pulse oximetry, we determined their HR and Spo2 before the intubation attempt. We then determined whether either or both fell by ≥10% during the attempt and, if so, at what time it occurred. RESULTS. We reviewed 122 video recordings in which orotracheal intubation was attempted 60 times in 31 infants. We secondarily verified ETT position using flow signals, ETCO2, or chest radiographs after 94% of attempts in which an ETT was introduced. Thirty-seven (62%) attempts were successful. Success rates and mean (SD) time to intubate successfully by group were as follows: residents: 24%, 49 seconds (13 seconds); fellows: 78%, 32 seconds (13 seconds); and consultants: 86%, 25 seconds (17 seconds). Of the 23 unsuccessful attempts, 13 were abandoned without an attempt to pass an ETT and 10 were placed incorrectly. The time to determine ETT position in the DR was longer when clinical assessment alone was used. Infants who were monitored with oximetry deteriorated during nearly half of the intubation attempts. Deterioration seemed more likely when HR and Spo2 were low before the attempt. CONCLUSIONS. Intubation attempts often are unsuccessful, and successful attempts frequently take >30 seconds. Greater experience is associated with greater success rates and shorter duration of successful attempts. Flow signals and ETCO2 may be useful in determining ETT position more quickly than clinical assessment alone. Infants frequently deteriorate during intubation attempts. Improved monitoring of infants who are resuscitated in the DR is desirable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textbook of Neonatal Resuscitation
(2021) · American Academy of PediatricsItasca, IL eBooks · doi:10.1542/9781610025256 · Cited by 1,002
Guidelines, C. A. R. F. T. N. R. (2000) · Pediatrics · doi:10.1542/peds.106.3.e29 · Cited by 720
Macintosh, M. C. M., & Cesdi (2003) · Cited by 21
Continuous Positive Airway Pressure: Randomized, Controlled Trial in Australia
Morley, C. J., Davis, P. G., & Doyle, L. W. (2001) · PEDIATRICS · doi:10.1542/peds.108.6.1383 · Cited by 16
Self-citation
Cited by
Kleinman, M. E., Chameides, L., Schexnayder, S. M., Samson, R. A., Hazinski, M. F., Atkins, D. L., Berg, M. D., de Caen, A. R., Fink, E. L., Freid, E. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971101 · Cited by 1,949
Nasal CPAP or Intubation at Birth for Very Preterm Infants
Morley, C. J., Davis, P. G., Doyle, L. W., Brion, L. P., Hascoet, J.-M., & Carlin, J. B. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa072788 · Cited by 1,354
Self-citationDelayed vs early umbilical cord clamping for preterm infants: a systematic review and meta-analysis
Fogarty, M., Osborn, D. A., Askie, L., Seidler, A. L., Hunter, K., Lui, K., Simes, J., & Tarnow-Mordi, W. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2017.10.231 · Cited by 530
Göpel, W., Kribs, A., Ziegler, A., Laux, R., Hoehn, T., Wieg, C., Siegel, J., Avenarius, S., von der Wense, A., Vochem, M., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60986-0 · Cited by 466
Berg, M. D., Schexnayder, S. M., Chameides, L., Terry, M., Donoghue, A., Hickey, R. W., Berg, R. A., Sutton, R. M., & Hazinski, M. F. (2010) · Pediatrics · doi:10.1542/peds.2010-2972c · Cited by 398
Neonatal Intubation Practice and Outcomes: An International Registry Study
Foglia, E. E., Ades, A., Sawyer, T., Glass, K. M., Singh, N., Jung, P., Quek, B. H., Johnston, L. C., Barry, J., Zenge, J., et al. (2019) · Pediatrics · doi:10.1542/peds.2018-0902 · Cited by 273
Finer, N. N., Rich, W., Wang, C., & Leone, T. (2009) · Pediatrics · doi:10.1542/peds.2008-0560 · Cited by 190
Nishisaki, A., Donoghue, A. J., Colborn, S., Watson, C., Meyer, A., Brown, C. A., Helfaer, M. A., Walls, R. M., & Nadkarni, V. M. (2010) · Anesthesiology · doi:10.1097/aln.0b013e3181e19bf2 · Cited by 163
“8 Sex Male 26 (33) Female 52 (67) Discipline Pediatrics 54 (69) Emergency medicine 24 (31) Training level PGY 1 4 (5) PGY 2 48 (62) PGY 3 20 (26) PGY 4 and 5 6 (8) Previous intubation (n) None 4 (5) 1–5 36 (46) 6–10 7 (9) 11–20 7 (9) 20 24 (31)”
Kleinman, M. E., de Caen, A. R., Chameides, L., Atkins, D. L., Berg, R. A., Berg, M. D., Bhanji, F., Biarent, D., Bingham, R., Coovadia, A. H., et al. (2010) · Pediatrics · doi:10.1542/peds.2010-2972a · Cited by 86
Metadata
- Authors
- O'Donnell, C. P. F., Kamlin, C. O. F., Davis, P. G., & Morley, C. J.
- Venue
- Pediatrics
- Publisher
- American Academy of Pediatrics (AAP)
- Published
- 2006-01-01
- Volume
- 117
- Issue
- 1
- Pages
- e16-e21
- ISSN
- 0031-4005 (ISSN-L)
- 1098-4275
- OpenAlex
- W2109404057
- Cited by
- 358
- References
- 4
- FWCI
- 13.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.