Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 293

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Sensitivity of Amplitude-Integrated Electroencephalography for Neonatal Seizure Detection

Shellhaas, Renée A., Soaita, Adina I., Clancy, Robert R. · 2007 · Pediatrics

Abstract

BACKGROUND. Conventional electroencephalography remains the gold standard for the diagnosis and quantification of neonatal seizures. However, amplitude-integrated electroencephalography (aEEG) is being introduced to neonatal intensive care as an adjunct for neonatal seizure detection. OBJECTIVES. This study's purpose was to determine the sensitivity of neonatal seizure detection in a single electroencephalogram channel (C3→C4), used to simulate the raw signal from which aEEG is derived. We also aimed to determine the sensitivity of seizure detection by neonatologists by using aEEG and to establish those neonatal seizure characteristics that are associated with their correct detection by aEEG. METHODS. Conventional electroencephalograms with neonatal seizures were reviewed for electroencephalogram background and neonatal seizure characteristics (site of onset, duration, and peak-to-peak amplitude). The presence, duration, and peak-to-peak amplitude of each seizure were simultaneously noted in a single electroencephalogram channel (C3→C4). aEEGs generated from this channel were reviewed for background and seizures by 6 neonatologists with varying aEEG interpretation expertise. RESULTS. A total of 851 neonatal seizures from 125 conventional electroencephalograms were analyzed. The patients' conceptional ages were 34 to 50 weeks. Because 94% of the conventional electroencephalograms had ≥1 neonatal seizure visible in C3→C4, and 78% of all neonatal seizures appeared in the C3→C4 channel, the theoretical sensitivity of seizure detection in a single electroencephalogram channel was high. However, seizures were briefer and lower in amplitude in C3→C4 compared with conventional electroencephalography. Neonatologists identified seizures in 22% to 57% of the 125 records of neonatal seizure. They detected 12% to 38% of the 851 individual seizures. Multivariate analysis revealed that the appearance of seizures in C3→C4, neonatal seizure duration, seizure amplitude, seizure count per hour, and neonatologists' experience with aEEG interpretation all correlated with neonatal seizure detection. CONCLUSIONS. Even among physicians who have extensive experience, many neonatal seizures are difficult to detect on an aEEG, especially when they are infrequent, brief, or of low amplitude.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1542/peds.2007-0514

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 293

Metadata

Authors
Shellhaas, R. A., Soaita, A. I., & Clancy, R. R.
Venue
Pediatrics
Published
2007-10-01
Volume
120
Issue
4
Pages
770-777
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W2026483359
Cited by
293
References
16
FWCI
14.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitivity of Amplitude-Integrated Electroencephalography for Neonatal Seizure Detection. https://app.cochat.ai/papers/10.1542/peds.2007-0514
The paper
Shellhaas, R. A., Soaita, A. I., & Clancy, R. R. (2007). Sensitivity of Amplitude-Integrated Electroencephalography for Neonatal Seizure Detection. Pediatrics. https://doi.org/10.1542/peds.2007-0514

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.