Magnetoelectric magnetic field sensors
The DOI matches its Crossref record.
Abstract
Highly sensitive magnetic field sensors using magnetoelectric (ME) bulk and thin-film composites consisting of magnetostrictive and piezoelectric phases are discussed. Examples include PZT (Pb(Zr_ x Ti_1– x )O_3) fibers and AlN as the piezoelectric component and amorphous magnetostrictive material, respectively, or their multilayers. Additionally, self-organized ME composites are discussed. These ME sensors offer a passive (consuming little to no power) nature, high sensitivities, large effect enhancements at mechanical resonances, and large linear dynamic ranges. At mechanical resonance, limits of detection in the fT/Hz^1/2 range can be achieved. Below the mechanical resonance frequency, the sensitivity can be enhanced through frequency conversion using alternating current magnetic or electric fields or by using magnetic field-induced changes of the elastic properties, the delta-E effect, where E represents Young’s modulus. Noise floors of about 1–100 pT/Hz^1/2 at a frequency of f = 1 Hz can be obtained depending on the sensor size and the operational mode. For applications in unshielded environments, approaches to suppress acoustic and vibrational cross-sensitivities are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
“The sensing element of such sensors is the magnetoelectric composite consisting of a magnetostrictive material which is mechanically coupled with the piezoelectric one or from single-phase multiferroic material [93,94].”
BackgroundMagnetoelectric effect: principles and applications in biology and medicine– a review
Kopyl, S., Surmenev, R., Surmeneva, M., Fetisov, Y., & Kholkin, A. (2021) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100149 · Cited by 202
“The direct ME effect forms a basis for sensors of permanent and low-frequency alternating magnetic fields with a sensitivity of up to ~10 11 T, operating at room temperature [21], solid-state inductors and transformers tuned by an electric field [1,38], energy harvesters, converting alternating-current (AC) magnetic f…”
BackgroundHarnessing the Heart’s Magnetic Field for Advanced Diagnostic Techniques
Elfouly, T., & Alouani, A. (2024) · Sensors · doi:10.3390/s24186017 · Cited by 19
Metadata
- Authors
- Viehland, D., Wuttig, M., McCord, J., & Quandt, E.
- Venue
- MRS Bulletin
- Published
- 2018-11
- Volume
- 43
- Issue
- 11
- Pages
- 834-840
- ISSN
- 0883-7694 (ISSN-L)
- 1938-1425
- OpenAlex
- W2899540137
- Cited by
- 102
- References
- 0
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetoelectric magnetic field sensors. https://app.cochat.ai/papers/10.1557/mrs.2018.261
- The paper
- Viehland, D., Wuttig, M., McCord, J., & Quandt, E. (2018). Magnetoelectric magnetic field sensors. MRS Bulletin. https://doi.org/10.1557/mrs.2018.261
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.